• Title/Summary/Keyword: average discharge

Search Result 736, Processing Time 0.032 seconds

Detection of Ultrasonic Signals by PD at the High Voltage Winding (고압권선에서 발생하는 부분방전에 의한 초음파 신호 검출)

  • Kweon, Dong-Jin;Kwak, Hee-Ro;Chung, Sang-Jin;Kim, Han-Sang;Song, Il-Keun;Kim, Kyoung-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.456-458
    • /
    • 1995
  • This paper describes a diagnosis of power transformers by on-line detection of ultrasonic signals. Partial discharge in power transformer generates ultrasonic signals. The trend of the ultrasonic signal number can be measured when partial discharge is generated in HV Winding. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based in the trend analysis of the number of ultrasonic signals caused by partial discharge.

  • PDF

Characteristics of Electropolymerization and Electrochemical Properties of Polyaniline (Pblyaniline의 전해중합특성 및 전기화학적 특성)

  • Moon, Seong-In;Yun, Mun-Soo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.9
    • /
    • pp.883-892
    • /
    • 1991
  • This paper presnets the characteristics of electropolymerization and electrochemicla propoerties of polyaniline(PAn). From the morphology study on the PAn surface, it seems that coagulation of the fibrils on the surface proceeds as the PAn grows, resulting in fibril clusters with new branches and more extensive voids. While PAn/Li cell is cycled at potential range between 2.9V and 3.7V in which the first strong reduction peak of 2.75V does not appear, its oxidation reduction capacities were increased up to about tenth cycle. Electricity efficiency of stable charge-discharge to deep discharge in PAn/Li cell was 42.9%. Average charge potential, avergae discharge potential, energy density, and charge-discharge energy efficiency of the PAn/Li cell were 3.4V, 3.25V, 132.9Wh/kg, and 95.6%, respectively.

Analysis and Performance Evaluation of DBD Actuator for Plasma Flow Control (플라즈마 유동 제어를 위한 DBD 엑츄에이터 해석 및 성능평가)

  • Lee, Chang-Wook;Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.290-293
    • /
    • 2012
  • The analysis and performance evaluation of DBD actuator for plasma flow control was described. The experimental apparatus was designed to measure the flow velocity as the discharge conditions, and to find out the optimal discharge condition of the DBD actuator. The average-velocity increased with increasing the discharge voltage. The experimental results was compared with CFD analysis.

  • PDF

An Experimental Study on the Estimation of Oil Discharge Rate from Inverter Rotary Compressor (인버터 로터리 압축기 오일 토출량 산정의 실험적 고찰)

  • Sin, Hyun-Seok;Byun, Soon-Seok;Tae, Sang-Jin;Moon, Je-Myung;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.28-32
    • /
    • 2011
  • The inverter rotary compressor discharges refrigerant and compressor oil in air-conditioning systems. The compressor oil which discharged form compressor decreases the efficiency of heat exchanger and affects the compressor operation. Recently, several studies are in progress for reducing the compressor oil. Before the reduction of compressor oil discharge rate, the quantitative measurement and evaluation method are required. In order to cope with this requirement we have developed the measurement technic of oil discharge rate. The reliability assessment was carried out approximately 0.1% of the errors with compressor performance indicators. The acceptable errors were to ensure the reliability of measurement technic. In the experiment results at several conditions, The oil discharge rate of heating operation has been confirmed average 3.7 times more than cooling operation. In this study the evaluation method and the experimental results of oil discharge rate in air-conditioning systems are presented with various operating conditions.

Development on Prediction Algorithm of Sediment Discharge by Debris Flow for Decision of Location and Scale of the Check Dam (사방댐 위치 및 규모 결정을 위한 토석류 토사유출량 예측 알고리즘 개발)

  • Kim, Kidae;Woo, Choongshik;Lee, Changwoo;Seo, Junpyo;Kang, Minjeng
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.586-593
    • /
    • 2020
  • Purpose: This study aims to develop an algorithm for predicting sediment discharge by debris flow, and develop GIS-based decision support system for optimal arrangement of check dam. Method: The average stream width and flow length were used to predict the cumulative sediment discharge by debris flow. At this time, the amount of slope failure on source area and average flow length were utilized as input factors. Result: The predicted sediment discharge calculated through the algorithm was 1.1 times different on average compared to the actual sediment discharge by debris flow. In addition, the program is an objective indicator that selects the location and size of the check dam, and it can help practitioners make rational decisions. Conclusion: The soil erosion control works are being implemented every year. Therefore, it is expected that the GIS-based decision support system for location and size of the check dam will contribute to the prevention of sediment-related disasters.

Evaluation of Circle Machining Surface Roughness on the Process Conditions using Neural Network (신경회로망을 이용한 가공조건에 따른 원형가공 표면거칠리 평가)

  • Sung, Baek-Sup;Kim, Ill-Soo;Cha, Yong-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2002
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to $6{\mu}s,\;8{\mu}s$ and $10{\mu}s$, pulse-off-time to $8{\mu}s,\;10{\mu}s$ and $13{\mu}s$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

Synthesis of Zirconium-Based Nanopowder by the Plasma Arc Discharge Process (플라즈마 아크 방전법에 의한 Zr계 나노분말 제조)

  • Lee, Gil-Geun;Kim, Kyong-Ju;Park, Je-Shin
    • Journal of Powder Materials
    • /
    • v.14 no.1 s.60
    • /
    • pp.63-69
    • /
    • 2007
  • The present study was focused on the synthesis of a zirconium-based alloyed nanopowder by the plasma arc discharge process. The chemical composition, phase structure, particle size and hydrogen sorption property of the synthesized powders under various synthesis conditions were analyzed using XRF, XRD, SEM, XPS and the ASTM-F798 method. The chemical composition of the synthesized Zr-V-Fe-based powders approached that of the raw material with an increasing hydrogen fraction in the powder synthesis atmosphere. The synthesized $Zr_{55}V_{29}Fe_{16}$ powder consist of a mixed phase structure of the $Zr,\;ZrH_2,\;FeV\;and\;Zr(V_{1-x}Fe_{x})_2$ phases. This powder has an average particle size of about 20 nm. The synthesized $Zr_{55}V_{29}Fe_{16}$ nanopowder showed getter characteristics, even though it had a lower hydrogen sorption speed than the $Zr_{57}\;V{36}\;Fe_7$ getter powder. However, the synthesized Zr nanopowder with an average particle size of 20 nm showed higher hydrogen sorption speed than the $Zr_{57}\;V{36}\;Fe_7$ getter powder.

Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin (낙동강수계 수질오염총량관리를 위한 유량조사 평가)

  • Kim, Gyeong-Hoon;Kim, Yong-Seok;Park, Bae-Kyung;Yoon, Jong-Su;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

Discharge of the Pollutants from Rice Paddies during the Period of Cultivation (경작기 농경배수에 의한 오염물질의 배출)

  • An, Ik-Sung;Kim, Youngchul;Lee, Dong-Ryul
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.266-273
    • /
    • 2007
  • In this study, discharge of the pollutants from the rice paddies during cultivation and its pattern were investigated. The pH in the returned and rainfall water from ten different paddies was between 6.9 and 7.4, which is not associated with the cultivation time and farming style of individual paddy. TN and TP concentrations were highest in the beginning of first top dressing (fertilization), which indicates that proper top dressing and returned water management is crucial to reduce their discharge loads. In particular, TN concentration was more or less constant until tillering stage. This is thought to be due to the runoff of soil-adsorbed nitrogen and compost. Average SS concentration in the returned and rainfall water was 28 mg/L, and organics was predominantly soluble form, and highest COD 25 mg/L during transplanting, lowest 11.3 mg/L and average 11.3 mg/L. Density of TC (total coliform bacteria) was from 1000/100 mL to 114,000/100 mL and FC (fecal coliform) was 5 to 16% of TC density.

Hydraulic Characteristics of Bocheong Stream Basin (보청천 유역의 수리학적 특성분석)

  • Jeon, Min-Woo;Yeon, Gyu-Bang;Cho, Young-Soo;Kim, Chong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1311-1315
    • /
    • 2009
  • Understanding of the hydraulics of flow is very important to support the management of river. The cross-sectional area, average velocity, flow depth and discharge can be regarded as a power function each other. In this paper the flow of Bocheong stream basin is experimentally studied. The correlation analysis was performed between observed hydraulic factors by the power type function. The constants resulted from the correlation analysis were calculated by the geomorphologic characteristics of the watershed using the power type function. The correlation coefficients between the hydraulic factors were appeared close to unit having strong correlationship. The two conditions of equality of the continuity equation were analysed, and the conditions were found to be good results. From these results the observed hydraulic data of Bocheong stream basin can be concluded as a reliable data. The correlation coefficients between the parameters of the hydraulic characteristics and geomorphologic factors were found to be close to unit.

  • PDF