• Title/Summary/Keyword: average case setting

Search Result 98, Processing Time 0.027 seconds

A Study on the Dose Constraints for Occupational Exposure: Focusing on Expert Opinions by Field of Ridiation Industry (직무피폭의 선량제약치에 관한 연구: 분야별 전문가 의견 중심으로)

  • Il Park;Chan Hee Park;Kyu Hwan Jung;Chan Ho Park;Yong Geon Kim;Tae Jin Park
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.61-67
    • /
    • 2023
  • A Study on the Introduction of Dose Constraints for Occupational Exposures: Focusing on Experts' Opinions by Field of Radiation Industry. The International Commission on Radiological Protection suggests Justification, Optimization, and Dose Limits as the three principles of radiological protection, among which, as a means of protection optimization, ICRP 103 recommends to set dose constraints. In this study, opinions are collected from experts in each category of radiation industries for stakeholder participation to qualify dose constraints. A guidance and questionnaire for analyzing the dose constraints have been developed for their collection, and opinions were collected from radiation protection experts in selected categories. 20 out of 22 experts, consisted with 91%, have assessed the dose constraints setting is necessary, and 2 experts, consisted with 9%, assessed it is unnecessary. The average of dose constraint presented by experts for RI production institutions is to be the highest level of 15.3 mSv, and light-water reactors (14.6 mSv), non-destructive inspection (14.4 mSv), heavy-water reactor and medical institutes (13.9mSv) is to be above the overall average dose constraint. In case of public institutions, the average dose constraint is to be 8.6mSv, and research institutions (8.8mSv), educational institutions (9.6 mSv), waste disposal sites (9.7 mSv), and general industries (10.6 mSv) are resulted to below the overall average dose constraint. As for the means of setting dose constraints, 8 experts out of 22 suggested setting dose constraints for each specific industry or task. And, 5 experts especially suggest setting dose constraints for the specific groups with relatively high exposure, such as workers with above the record levels. As a countermeasure for workers who exceed the dose constraints, 15 experts out of 22 expressed that the cause analyses for them and preparation for a plan of reducing them are necessary.

Cost-Effectiveness of Voluntary HIV Testing Strategies in a Very Low-Prevalence Country, the Republic of Korea

  • Lee, Young Hwa;Bang, Ji Hwan;Park, Sang Min;Kang, Cho Ryok;Cho, Sung-Il;Oh, Myoung-don;Lee, Jong-Koo
    • Journal of Korean Medical Science
    • /
    • v.33 no.46
    • /
    • pp.304.1-304.7
    • /
    • 2018
  • Background: The Republic of Korea has a very low prevalence of human immunodeficiency virus (HIV) infection, but the number of new HIV diagnoses has steadily risen, strongly indicating a large number of undetected HIV infections. Thus, it is important for Korean public health authorities to adopt and encourage cost-effective HIV detection tools, such as rapid HIV screening tests. In this study, we aimed to evaluate the cost-effectiveness of enzyme-linked immunosorbent assays (ELISA) and rapid tests in a public health center (PHC) setting. Methods: We developed a decision analytic model to assess the per-examinee cost and the cost-effectiveness of identifying HIV patients in a PHC setting using two HIV testing strategies: conventional HIV screening by ELISA versus rapid HIV testing. Analysis was performed in two scenarios: HIV testing in an average-risk population and in a high-risk population. Results: Compared to the ELISA, the rapid test was cost-saving and cost-effective. The per-examinee cost was USD 1.61 with rapid testing versus USD 3.38 with ELISA in an average-risk population, and USD 4.77 with rapid testing versus USD 7.62 with ELISA in a high-risk population. The cost of identifying a previously undiagnosed HIV case was USD 26,974 with rapid testing versus USD 42,237 with ELISA in an average-risk population, and USD 153 with rapid testing versus USD 183 with ELISA in a high-risk population. Conclusion: Rapid testing would be more cost-effective than using conventional ELISA testing for identifying previously undiagnosed HIV-infected cases in Korea, a country with extremely low HIV prevalence.

Evaluation of Groundwater Flow Analysis Using Rainfall-Recharge Estimation Methods

  • Choi, Yun-Yeong;Sim, Chang-Seok;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.561-569
    • /
    • 2007
  • This study used SCS-CN method to estimate the real recharge of the study area which is one of the most reasonable techniques to estimate groundwater recharge when there is no available runoff data in a watershed. From the results of tile real recharge analysis for the study area using SCS-CN method, it was analyzed that the year 1994 when the drought was severe shotted the lowest recharge of 106.3mm with recharge rate of 12.4%, and the highest recharge of 285.6mm with recharge rate of 21.8% occurred in 1990. Yearly average recharge of 213.2mm was obtained, and tile average recharge rate was 16.9%/year. KOG-FLOW model which has powerful post process functions consists of setting environments for input parameters in Korean language, and help function is added to each input data. Detailed information for each parameter is displayed when the icon is placed on the input parameters, and geologic boundaries or initial head data for each layer can be set easily on work sheet. The relative errors (R. E.) for each model's observed values and calculated values are $0.156{\sim}0.432$ in case of KOG-FLOW, and $0.451{\sim}1.175$ in case of WINFLOW, therefore it is known that KOG-FLOW model developed in this study produced results compared to observed head values.

Optimal Threshold Setting Method for R Wave Detection According to The Sampling Frequency of ECG Signals (심전도신호 샘플링 주파수에 따른 R파 검출 최적 문턱치 설정)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1420-1428
    • /
    • 2017
  • It is difficult to guarantee the reliability of the algorithm due to the difference of the sampling frequency among the various ECG databases used for the R wave detection in case of applying to different environments. In this study, we propose an optimal threshold setting method for R wave detection according to the sampling frequency of ECG signals. For this purpose, preprocessing process was performed using moving average and the squaring function based the derivative. The optimal value for the peak threshold was then detected according to the sampling frequency by changing the threshold value according to the variation of the signal and the previously detected peak value. The performance of R wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. When the optimal values of the differential section, window size, and threshold coefficient for the MIT-BIH sampling frequency of 360 Hz were 7, 8, and 6.6, respectively, the R wave detection rate was 99.758%.

A Feasibility Study of Acupuncture for Chronic Pain in Patients with Osteoporotic Thoracolumbar Compression Fracture: A Prospective Case Series

  • Bae, Ji min;Choi, Ji won;Kim, Dae hun;Yang, Gi Young;Kim, Kun hyung
    • Journal of Acupuncture Research
    • /
    • v.35 no.2
    • /
    • pp.75-80
    • /
    • 2018
  • Background: The aim of this study was to assess the feasibility of conducting a clinical study of using acupuncture for chronic pain in patients with osteoporotic thoracolumbar vertebral compression fractures (VCFs) in the outpatient setting. Methods: A prospective case-series attempting to recruit 20 participants was performed from February 11, 2016, to December 31, 2016. We provided Manual and electrical acupuncture was provided one 1 to three 3 times a week, for 6 weeks, up to 18 sessions. The primary clinical outcome was the average pain intensity as measured by the visual analog scale (VAS) at 6 weeks. Secondary outcomes included back-specific dysfunction (Oswestry disability index), quality of life (quality of life questionnaire-26), patient-reported improvement, use of other healthcare resources, and adverse events at 6 weeks. Use of healthcare resources and adverse events were additionally followed-up at 12 weeks by telephone. Results: Of 33 patients screened, a total of 7 were enrolled in the study. Manual and electrical acupuncture was provided 1 to 3 times a week, for 6 weeks, up to 18 sessions. We observed reduced pain intensity at 6 weeks in all participants. The change in the quality of life and back-specific dysfunction was inconsistent among participants. Mild, temporary adverse events were observed in three patients. Conclusion: In our clinical setting, it was not feasible to recruit sufficient participants and to assess the efficacy of acupuncture for chronic pain after osteoporotic thoracolumbar VCFs under a year. Strategies to improve recruitment and to identify barriers to participation are required for future clinical trials.

Performance estimation of conical picks with slim design by the linear cutting test (II): depending on skew angle variation (선형절삭시험에 의한 슬림 코니컬커터의 절삭성능 평가(II): Skew Angle 변화에 의한 결과)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Park, Young-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.585-597
    • /
    • 2014
  • In this study, the cutter acting forces were measured by 3-directional load cell at two different skew angles and various S/d ratios during a series of linear cutting tests using a slim conical pick. The analysis for cutting performance were carried out after calculating average values of the measured results. The increase of penetration depth results in the decrease of specific energy. And the variations of the cutter acting forces depending on penetration depth in the case of 6 degree skew angle were smaller than in the case of 0 degree skew angle. From this results, 6 degree skew angle is more effective than 0 degree skew angle in designing optimal specifications of cutting head. In addition, $F_c/F_n$ under the setting of 6 degree skew angle was smaller than under the setting of 0 degree skew angle. However, it should be considered that the increase of cutter acting force in the cutting direction accompanied the increase of driving force in the case of the setting for 6 degree skew angle.

Design and Estimation of Multiple Acceptance Sampling Plans for Stochastically Dependent Nonstationary Processes (확률적으로 종속적인 비평형 다단계 샘플링검사법의 설계 및 평가)

  • Kim, Won-Kyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.1
    • /
    • pp.8-20
    • /
    • 1999
  • In this paper, a design and estimation procedure for the stochastically dependent nonstationary multiple acceptance sampling plans is developed. At first, the rough-cut acceptance and rejection numbers are given as an initial solution from the corresponding sequential sampling plan. A Monte-Carlo algorithm is used to find the acceptance and rejection probabilities of a lot. The conditional probability formula for a sample path is found. The acceptance and rejection probabilities are found when a decision boundary is given. Several decision criteria and the design procedure to select optimal plans are suggested. The formula for measuring performance of these sampling plans is developed. Type I and II error probabilities are also estimated. As a special case, by setting the stage size as 1 in a dependent sampling plan, a sequential sampling plan satisfying type I and II error probabilities is more accurate and a smaller average sample number can be found. In a numerical example, a Polya dependent process is examined. The sampling performances are shown to compare the selection scheme and the effect of the change of the dependency factor.

  • PDF

Discussions on Applying Program Outcomes to Graduation Requirements in ABEEK (학습성과 달성도의 공학교육인증 졸업기준 적용에 대한 논의점)

  • Park, Jin-Won
    • Journal of Engineering Education Research
    • /
    • v.14 no.4
    • /
    • pp.62-68
    • /
    • 2011
  • Many engineering schools in Korea implement ABEEK programs. One of the core parts of ABEEK is accreditation criterion 2, the program outcomes and their appraisal. This paper tries to discuss the program outcomes and to study the impact of applying the program outcomes to one of the graduation requirements. We show simple survey results for implementing ABEEK programs concerning the program outcomes and their relation to graduation requirements. If the program outcomes are used as one of the graduation requirements, some graduates may satisfy the average grade point for graduation requirements but can not meet the program outcome criteria satisfied by other than regular classes. In this case, the graduate may have trouble to try to meet the program outcome criteria, since he may not be able to stay in school without taking classes. The problems of setting the levels of program outcomes as graduation requirements, non classwork related program outcomes, and work burden to professors should be also prudently reviewed for successful ABEEK implementation.

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

A Case Study of Three Dimensional Human Mimic Phantom Production for Imaging Anatomy Education (영상해부학 교육을 위한 3차원 인체 모사 조형물 제작 사례 연구)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • In this study, human mimic phantoms outputted by three-dimensional (3D) printing technology are reported. Polylactic acid and a personal 3D printer - fused deposition modeling (FDM) - are used as the main material and the printing device. The output of human mimic phantoms performed in the following order: modeling, slicing and G-code conversion, output variable setting, 3D output, and post-processing. The students' learning satisfaction (anatomical awareness, study interest) was measured on 5-point Likert scale. After that, Twenty of those phantoms were outputted. The total output took 11,691 minutes (194 hours 85 minutes) and the average output took 584.55 minutes (9 hours 7 minutes). The filament used for the experiment was 2,390.2 g, and the average use of the filament was 119.51 g. The learning satisfaction of anatomical awareness was 4.6 points on the average and the interest of the class was on average 4.5 points. It is expecting that 3D printing technology can enhance the learning effect of imaging anatomy education.