• 제목/요약/키워드: autopolymerized resin

검색결과 6건 처리시간 0.021초

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구 (A STUDY ON THE DEGREE OF POLYMERIZATION OF AUTOPOLYMERIZED RESIN FOR REMOVABLE ORTHODONTIC APPLIANCE ACCORDING TO CURING TIME AND CURING METHOD)

  • 유종욱;장기택;김종철
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.296-309
    • /
    • 1999
  • 가철성 상교정 장치에 많이 사용되는 자가중합형 상교정용 레진의 미반응 단량체는 레진의 물성과 생물학적인 면에 많은 영향을 끼친다. 따라서 미반응 단량체를 최소화하고 중합률을 최대로 하는 중합방법에 대한 연구는 중요한 의의를 갖는다. 저자는 자가중합형 상교정용 레진의 중합시간과 중합방법에 따른 중합률을 비교해보기 위해 시편을 다음과 같이 5군으로 나누어 연구를 진행하였다. 상교정용 레진의 분말과 용액을 혼합하여 제 1군은 $28^{\circ}C$의 공기중에 보관하였고, 제 2군은 $28^{\circ}C$의 물에, 제 3군은 $28^{\circ}C$의 물과 30psi의 압력에, 제 4군은 $43^{\circ}C$의 물에, 제 5군은 $43^{\circ}C$의 물과 30psi의 압력하에 각각 보관하였고, 10분, 1시간, 12시간, 1일, 3일 경과 후에 각 시편을 Fourier 변환적외선분광법을 이용하여 중합률을 측정하여 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합시간이 경과함에 따라 중합률도 지속적으로 증가하는 양상을 보였다. 10분 경과 후의 결과와 비교하여 볼 때, 제 1군은 12시간 경과 후부터 중합률의 증가가 유의성이 있었고, 제 2군과 3군, 4군, 5군은 1시간 경과 후부터 유의성이 있었다(p<0.05). 2. 10분과 1일, 3일 경과 후에 제 5군, 제 4군, 제 3군, 제 2군, 제 1군의 순서대로 중합률이 높았다. 3. 중합시 온도에 따른 비교에서, 1일 경과 후를 제외하고는 모든 시간에서 $43^{\circ}C$에서 중합시킨 군의 중합률이 $28^{\circ}C$에서 중합시킨 군의 중합률 보다 유의성 있게 높았다(p<0.05). 4. 압력은 12시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다. 5. 보관방법은 1시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다.

  • PDF

Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin

  • Viotto, Hamile Emanuella do Carmo;Silva, Marcela Dantas Dias;Nunes, Thais Soares Bezerra Santos;Coelho, Sabrina Romao Goncalves;Pero, Ana Carolina
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.305-314
    • /
    • 2022
  • PURPOSE. The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS. Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS. Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION. Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

  • Lee Hyeok-Jae;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.360-368
    • /
    • 2003
  • Statement of Problem: The residual monomer of denture base materials causes hypersensitivity on oral mucosa and intereferes with the mechanical properties of the cured resin. The amount of residual monomer is influenced by materials, curing cycle, processing method, and etc. Purpose: The aim of this study was to investigate the residual methyl methacrylate(MMA) content of injection molded denture base polymer, and to compare this with the self-cured resin and the conventional compression molded heat-cured resin. Materials and Methods: Disc shaped test specimens (50mm in diameter and 3mm thick) were prepared in a conventional flasking technique with gypsum molding. One autopolymerized denture base resins (Vertex Sc. Dentimex. Netherlands) and two heat-cured denture base resins (Vertex RS. Dentimex. Netherlands, Ivocap. Ivoclar Vivadent, USA) were used. The three types of specimens were processed according to the manufacturer's instruction. After polymerization, all specimens were stored in the dark at room temperature for 7 days. There were 10 specimens in each of the test groups. 3-mm twist drills were used to obtain the resin samples and 650mg of the drilled sample were collected for each estimation. Gas chromatography (Agillent 6890 Plus Gas Chromatograph, Agillent Co, USA) was used to determine the residual MMA content of 10 test specimens of each three types of polymer. Results: The residual monomer content of injection molded denture base resins was $1.057{\pm}0.141%$. The residual monomer content of injection molded denture base resins was higher than that of compression molded heat cured resin ($0.867{\pm}0.169%$). However, there was no statistical significant difference between two groups (p>0.01). The level of residual monomer in self cured resin($3.675{\pm}0.791$) was higher than those of injection molded and compression molded heat cured resins (p<0.01). Conclusion: With respect to ISO specification pass / fail test (2.2% mass fraction) of residual monomer, injection molding technique($1.057{\pm}0.141%$) is a clinically useful and safe technique in terms of residual monomer.

Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy

  • Kulunk, Safak;Kulunk, Tolga;Sarac, Duygu;Cengiz, Seda;Baba, Seniha
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.272-277
    • /
    • 2014
  • PURPOSE. The purpose of this study was to investigate the impact of different surface treatment methods and thermal ageing on the bond strength of autopolymerizing acrylic resin to Co-Cr. MATERIALS AND METHODS. Co-Cr alloy specimens were divided into five groups according to the surface conditioning methods. C: No treatment; SP: flamed with the Silano-Pen device; K: airborne particle abrasion with $Al_2O_3$; Co: airborne particle abrasion with silica-coated $Al_2O_3$; KSP: flamed with the Silano-Pen device after the group K experimental protocol. Then, autopolymerized acrylic resin was applied to the treated specimen surfaces. All the groups were divided into two subgroups with the thermal cycle and water storage to determine the durability of the bond. The bond strength test was applied in an universal test machine and treated Co-Cr alloys were analyzed by scanning electron microscope (SEM). Two-way analysis of variance (ANOVA) was used to determine the significant differences among surface treatments and thermocycling. Their interactons were followed by a multiple comparison' test performed uing a post hoc Tukey HSD test (${\alpha}=.05$). RESULTS. Surface treatments significantly increased repair strengths of repair resin to Co-Cr alloy. The repair strengths of Group K, and Co significantly decreased after 6,000 cycles (P<.001). CONCLUSION. Thermocycling lead to a significant decrease in shear bond strength for air abrasion with silica-coated aluminum oxide particles. On the contrary, flaming with Silano-Pen did not cause a significant reduction in adhesion after thermocycling.

치과 교정용 자가중합형 Resin의 중합 온도 변화에 따른 굽힘 특성 (Flexural Properties according to Change of Polymerization Temperature of Autopolymerized Resin for Orthodontic)

  • 이규선
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.259-264
    • /
    • 2015
  • 치과 교정용 자가중합형 레진의 중합 온도가 기계적 특성에 미치는 영향을 알아보기 위하여 폴리머와 모노머의 부피비는 2.5:1로 하고, 중합 온도를 $25^{\circ}C$, $40^{\circ}C$, $70^{\circ}C$의 세 group으로 나누었다. 실험을 위해 각 group 당 10개씩의 시편을 중합 시간 15분, 중합 압력 3 bar로 통일하여 제작하였다. 그 후 시편을 실험 전까지 $37^{\circ}C$의 증류수에 48시간 이상 보관한 다음, Intron (3344)을 이용하여 각 시편의 FS 및 EM을 측정하였다. 이렇게 하여 얻어진 값들은 SPSS ver. 16.0을 사용하여 일원 배치 분산 분석을 하였으며 Scheffe의 사후 검정을 실시하여 다음과 같은 결과를 얻었다. 치과 교정용 자가중합형 레진의 FS 평균값을 비교해 보았을 때 $25^{\circ}C$ group은 $71.500{\pm}5.546MPa$, $40^{\circ}C$ group은 $74.920{\pm}4.237MPa$, $70^{\circ}C$ group은 $76.880{\pm}4.304MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 차이가 있었으나 통계적으로 유의한 차이는 없었다(p=0.052). 치과 교정용 자가중합형 레진의 EM 평균값은 $25^{\circ}C$ group이 $2.164{\pm}0.073MPa$, $40^{\circ}C$ group은 $2.258{\pm}0.069MPa$, $70^{\circ}C$ group은 $2.282{\pm}0.147MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 중합 온도가 높을수록 유의한 차이를 보였다(p<0.039). 이상의 실험 결과로 미루어 볼 때 EM 값은 $25^{\circ}C$ group<$40^{\circ}C$ group<$^70{\circ}C$ group 순으로 통계적 유의성이 인정되는 수준의 상승이 있었던 반면, FS 값은 통계적 유의성은 보이고 있지 않으나 강도의 증가에 영향을 미치고 있으므로, 치과 교정 장치 제작 시 일정 수준의 중합 온도 상승은 장치의 기계적 물성을 증가시킬 것이라고 판단된다.