• Title/Summary/Keyword: automatic test report program

Search Result 8, Processing Time 0.027 seconds

Automatic Test Report Recording Program Design and Implementation for Integration Test (통합시험을 위한 자동 시험일지 작성프로그램 설계 및 구현)

  • Jeong, Younghwan;Song, Kyoungrok;Lee, Wonsik;Wi, Sounghyouk
    • KIISE Transactions on Computing Practices
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • For the integration test in the current field of defense simulation, each actual equipment and simulator's logging information is automated. Although the event of the integrated test system is written in the test log, it is not automated, and relies on the operator's handwriting or file creation, resulting in ineffective aspects such as low-quality record content and repetition of the same content. In this study, we propose the automatic test report recording program that solves these problems. Automatic test report recording program uses framework-based technology to receive information from the test control computer and user to record a log of the test log. Automatic test report recording program allows the user to record the repeated test content in a stable manner. Additionally, even if the number of test operators is limited, the efficiency is improved so that we can fucus on the integration test.

A Report on Test Results of Pressure Operated Switch (압력스위치 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

A Report on Test Results of Fusible-Link Type Heat Responsive Links (Fusible Link Type 감열체 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.5-8
    • /
    • 1991
  • This report is explained about test results of heat responsive links for fire protection service, such as fire dampers and fire doors, automatic fire suppression systems and so forth. The testing program was progressed divided by two testing items, external appearance test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

The effects of a group cognitive behavioral therapy program using video communication for pregnant women with depressed mood in Korea: a pilot study

  • Lee, Eunjoo;Kim, Mijung
    • Women's Health Nursing
    • /
    • v.27 no.4
    • /
    • pp.337-347
    • /
    • 2021
  • Purpose: This study presents the development of a group video communication-based cognitive behavioral therapy (CBT) program for depressed pregnant women. It also provides the results of a preliminary test of its effects on their depression, automatic thoughts, and dysfunctional attitudes. Methods: In this quasi-experimental single-group pre- and posttest design study, 13 pregnant women participated in a 4-week, eight-session group CBT program, based on Beck's cognitive theory and using video communications from November 2020 to January 2021. Pregnant women between 14 and 32 weeks who were members of an online maternity and parenting community and residing in the cities of Changwon and Gimhae, Korea, were invited to voluntarily participate. Trained nurses led CBT sessions of 3-4 participants per group via video communication. Participants were assessed pre- and postintervention with self-report questionnaires for measurement of depression, automatic thought, and dysfunctional attitude after normality test according to the Shapiro-Wilk test of the variables. The data were analyzed using paired t-test and Pearson correlation coefficients. Results: Depression (t=7.90, p<.001), automatic thoughts (t=4.89, p<.001), and dysfunctional attitudes (t=2.42, p=.032) significantly decreased after the 4-week online program. There were statistically significant correlations among the three variables. Conclusion: This program was found to be effective in reducing depression, automatic thoughts, and dysfunctional attitudes. Above findings suggest that a group CBT program using video communication can be an effective therapeutic modality that helps pregnant women at risk for depression alleviate their negative emotions related to depression.

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

Development of Automatic System for Estimation of Digital Relay Performance (Digital Relay 자동성능평가 시스템 개발)

  • Min, Byoung-Woon;Park, Dong-Ho;Kim, Jung-Han;Choi, Hang-Sub;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.510-512
    • /
    • 2005
  • This paper introduces the development of automatic system for estimation of digital relay performance. We have developed an automatic estimation system "HRV2004(Himap Relay function Verifier 2004)" for digital relay in 2004 and it has been verified in the field for one years. This paper describes the development details and field experience of HRV2004. HRV2004 can perform a series of jobs required for the relay testing in one environment and could handle most of all models of protective relay currently produced by Hyundai Heavy Industries. The functionality of this program consists of GUI of relay setting for beginner, fault record analysis and relay performance estimation. The core of this system is an automatic reporting of estimation test. If user is only click a button for relay estimation and one will received testing report to deliver customer. Additional benefit is fast response than the manual estimation. For example, the manual estimation takes spending 6 hours but this system is about 15 minutes.

  • PDF

Validation Testing of Safety-critical Software (Safety-critical 소프트웨어의 검증시험)

  • Kim, Hang-Bae;Han, Jai-Bok
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.385-392
    • /
    • 1995
  • A software engineering process has been developed for the design of safety critical software for Wolsong 2/3/4 project to satisfy the requirement of the regulatory body. Among the process, this paper described the detail process of validation testing peformed to ensure that the software with its hardware, developed by the design group, satisfies the requirements of the functional specification prepared by the independent functional group. To perform the test, test facility and test software ore developed and actual safety system computer was connected. Three kinds of test cases, i.e., functional test performance test and self-check test were programmed and run to verify each functional specifications. Test failures ore fedback to the design group to revise the software and test result were analyzed and documented in the report to submit to the regulatory body. The test methodology and procedure were very efficient and satisfactory to perform the systematic and automatic test. The test results were also acceptable and successful to verify the software acts as specified in the program functional specification. This methodology can be applied to the validation of other safety-critical software.

  • PDF

REAL-TIME QUALITY EVALUATION OF FRICTION WELDING OF MACHINE COMPONENTS BY ACOUSTIC EMISSION (음향방출법(AE)에 의한 기계요소재의 마찰용접 품질 실시간 평가)

  • SAE-KYOO OH
    • Proceedings of the KWS Conference
    • /
    • 1995.10a
    • /
    • pp.3-20
    • /
    • 1995
  • Development of Real-Time Quality Evaluation of Friction Welding by Acousitc Emission : Report 1 ABSTRACT : According as the friction welding has been increasingly applied in manufacturing various machine components because of its significant economic and technical advantages, one of the important concerns is the reliable quality monitoring method for a good weld quality with both joint strength and toughness in the process of its production. However no reliable nondestructive test method is available at present to determine the weld quality particularly in process of production. So this paper presents an experimental examination and quantitative analysis for the real-time evaluation of friction weld quality by acoustic emission, as a new approach which attempts finally to develop an on-line quality monitoring system design for friction welds using AE techniques. As one of the important results, it was confirmed, through this study, that AE techniques can be reliably applied to evaluating the friction weld qualify with 100% joint strength, as the cumulative AE counts occurring during welding period were quantitatively correlated with reliability at 95% confidence level to the joint strength of welds. Real-Time Evaluation of Automatic Production Quality Control for Friction Welding Machine : Report 2 Abstract : Both in-process quality control and high reliability of the weld is one of the major concerns in applying friction welding to the economical and qualified mass-production. No reliable nondestructive monitoring method is available at present to determine the real-time evaluation of automatic production quality control for friction welding machine. This paper, so that, presents the experimental examinations and statistical quantitative analysis of the correlation between the initial cumulative counts of acoustic emission(AE) occurring during plastic deformation period of the welding and the tensile strength of the welded joints as well as the various welding variables, as a new approach which attempts finally to develop an on-line (or real-time) quality monitoring system and a program for the process of real-time friction welding quality evaluation by initial AE cumulative counts. As one of the important results, it was well confirmed that the initial AE cumulative counts were quantitatively and cubically correlated with reliability of 95% confidence level to the joint strength of the welds, bar-to-bar (SCM4 to SUM31, SCM4 to SUM24L) and that an AE technique using initial AE counts can be reliably applied to real-time strength evaluation of the welded joints, and that such a program of the system was well developed resulting in practical possibility of real-time quality control more than 100% joint efficiency showing good weld with no micro-structural defects.

  • PDF