• Title/Summary/Keyword: automatic mixing

Search Result 53, Processing Time 0.022 seconds

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

A study on the development of PCB automatic routing system using the mixing method of non-grid and grid (논-그리드와 그리드 혼합 방식을 이용한 PCB 자동 배선 시스템 개발)

  • Choe, Yeong-Gyu;Lee, Cheon-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.4
    • /
    • pp.592-602
    • /
    • 1995
  • Non-grid and grid method are used for modeling the routing region of the automatic routing system. In this study, we develop the automatic routing system by mixing the methods of non-grid and grid to improve the speed of routing. Grid method has a demerit which decreases the automatic routing speed because it is required a lot of memory by the limitation of the size of board and grid, although the electrical and physical elements are insufficient on the PCB, But non-grid is spent gurite less memory than grid method by using a shape-based patterns. Therefore, we used the methods of non-grid and grid altogether in this paper, In the former method, it is attributed to the improvement of speed, the latter one is applied only the connection of the failed routing in the former one, and it performs the complete automatic routing. This system was developed with C++language under the Windows NT environment of IBM 486DX2-66 Computer.

  • PDF

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

A Study on the Automatic Measurement of Solid Content in Recycled Water in Ready Mixed Concrete Plant (레디믹스트 콘크리트 플랜트의 회수수 농도 측정 자동화에 관한 연구)

  • Choi, Young-Cheol;Moon, Gyu-Don;Cho, Bong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.123-131
    • /
    • 2014
  • Whole amount of waste water, approximately 921.6 liter, for cleaning a ready mixed concrete truck should be used to produce concrete as a mixing water or cleaning water. Recycling water for concrete mixing contains solids, which cause decrease in slump, air and compressive strengths, so it may influence on poor concrete quality. Therefore, it has been maintained to use recycling water with less than 3 percent of solids. Since no evaluation system has been constructed to directly reflect on variability of recycling water from ready mixed concrete plants, it is necessary to develop "Automatic recycling solid measuring system" for quality controls in real time. In this research, sensors measuring waste water concentration in ultrasonic and inductance methods were developed, and automatic system using the sensors were established. The accuracy of measurement sensors developed for recycling water based on various conditions of concentration was proved, and application limits were evaluated. Also, concentration of recycling water using sensors developed from ready mixed concrete plant was measured, and curing method verified the accuracy of the sensors. Moreover, measurement sensors for recycling water in various locations were installed to evaluate the effects on measuring method and spots. The automatic measuring system for recycling water concentration, which is developed in the research, will contribute to improve concrete quality safety through reliable solids maintenance.

Polishing Characteristics and Development of Automatic Die Polishing Machine by Liquid Honing (액체호닝에 의한 금형 자동 사상기계개발 및 가공 특성)

  • 김재도;류기덕;홍정석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.162-168
    • /
    • 2000
  • The automatic die polishing machine by liquid honing has been developed and experimented on the surface of machined die. The goal of development in the automatic die polishing machine by liquid honing is to increase the accuracy and the productivity in die polishing. To reach this goal, the polishing machine consists of the automatic measuring device for contour of die, the nozzle and pumping system to spray the powder mixed with liquid, and the 3-axis guides. Before polishing, the measuring device with a semiconductor laser scans the surface of mould to get the data of contour. The data store a PC and use to control the nozzle head to move above a couple of centimeters on the machined surface of die. The experimental parameters are the spraying time, the pressure, the size of abrasive grain and the mixing ratio between abrasive grain and liquid. The surface roughness is measured on the polished die which are SKDl 1 and Al7075 machined by NC. The surface roughness indicates the values of Rmax 0.5${\mu}{\textrm}{m}$ for Al7075 and Rmax 1.4${\mu}{\textrm}{m}$ for SKDl 1. It reduces the polishing time significantly and reduces the monotonous work for labors. As the results, the liquid honing system is useful method to apply for the die polishing and the automatic die polishing machine using liquid honing shows that it's very effective processing ability.

  • PDF

Underdetermined Blind Source Separation from Time-delayed Mixtures Based on Prior Information Exploitation

  • Zhang, Liangjun;Yang, Jie;Guo, Zhiqiang;Zhou, Yanwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2179-2188
    • /
    • 2015
  • Recently, many researches have been done to solve the challenging problem of Blind Source Separation (BSS) problems in the underdetermined cases, and the “Two-step” method is widely used, which estimates the mixing matrix first and then extracts the sources. To estimate the mixing matrix, conventional algorithms such as Single-Source-Points (SSPs) detection only exploits the sparsity of original signals. This paper proposes a new underdetermined mixing matrix estimation method for time-delayed mixtures based on the receiver prior exploitation. The prior information is extracted from the specific structure of the complex-valued mixing matrix, which is used to derive a special criterion to determine the SSPs. Moreover, after selecting the SSPs, Agglomerative Hierarchical Clustering (AHC) is used to automaticly cluster, suppress, and estimate all the elements of mixing matrix. Finally, a convex-model based subspace method is applied for signal separation. Simulation results show that the proposed algorithm can estimate the mixing matrix and extract the original source signals with higher accuracy especially in low SNR environments, and does not need the number of sources before hand, which is more reliable in the real non-cooperative environment.

Automatic DJ Mixing System based on Song Structure Analysis (노래 구조 분석에 기반한 DJ 믹싱 자동화 시스템)

  • Jun, Sanghoon;Hwang, Eenjun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.359-360
    • /
    • 2009
  • 최근 활발해진 여러 유형의 생활 문화 축제에서나 음악 스트리밍 방송과 같은 서비스에서 멈춤없이 계속적으로 음악을 재생할 수 있도록 여러 음악을 조화롭게 혼합하는 믹싱(Mixing) 기술을 담당하는 DJ(Disc-Jockey)의 역할이 중요시되고 있다. 본 논문에서는 이러한 DJ 믹싱 기능을 자동화할 수 있는 방법에 대하여 제안한다. 우선, 여러 음악이 가지는 구조를 분석하여 믹싱에 적합한 음악 부분을 검출한다. 또한 음악 믹싱에 필요한 요소인 템포 분석과 비트 매칭(Beat matching)을 자동화하고, Easy Mix System 을 적용하여 해당 음악에 적합한 다른 음악을 찾아 조화로운 키를 가지게 함으로써 보다 자연스러운 믹싱이 가능하도록 한다.

Development of Preprocessor for Real-time Quality Evaluation of Milk - Automatic Supplying, Mixing and Temperature Control - (우유의 실시간 품질판정을 위한 전처리장치 개발 - 자동 공급, 혼합 및 온도 제어 -)

  • Choi, C.H.;Kim, Y.J.;Kim, J.D.;Kim, K.S.;Noh, H.W.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.130-135
    • /
    • 2008
  • The purpose of this study was to develop a preprocessor for real-time portable quality evaluation system of milk. The preprocessor consisted of two flow pump to supply milk sample and reaction reagent at given volume, a fan to mix milk with reaction reagent, a thermoelectric device to maintain sample temperatures of $40^{\circ}C$, and I/O interface to control signals. The tests conducted with different level of flow rate of pump, fan speed, ambient temperature, and intial temperature of mixtures. To evaluate performance of the preprocessor, the supplied volumes, color changes, and temperatures were measured and analyzed. The results showed that the preprocessor could control supplying volumes, mixing, temperatures of samples automatically. The preprocessor showed good performance to be used for portable quality evaluation system of milk.

Observed Data Oriented Bispectral Estimation of Stationary Non-Gaussian Random Signals - Automatic Determination of Smoothing Bandwidth of Bispectral Windows

  • Sasaki, K.;Shirakata, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.502-507
    • /
    • 2003
  • Toward the development of practical methods for observed data oriented bispectral estimation, an automatic means for determining the smoothing bandwidth of bispectral windows is proposed, that can also provide an associated optimum bispectral estimate of stationary non-Gaussian signals, systematically only from an observed time series datum of finite length. For the conventional non-parametric bispectral estimation, the MSE (mean squared error) of the normalized estimate is reviewed under a certain mixing condition and sufficient data length, mainly from the viewpoint of the inverse relation between its bias and variance with respect to the smoothing bandwidth. Based on the fundamental relation, a systematic method not only for determining the bandwidth, but also for obtaining the optimum bispectral estimate is presented by newly introducing a MSE evaluation index of the estimate only from an observed time series datum of finite length. The effectiveness and fundamental features of the proposed method are illustrated by the basic results of numerical experiments.

  • PDF