• 제목/요약/키워드: augmentation mammoplasty

검색결과 22건 처리시간 0.016초

Selection of Implants in Unilateral Prosthetic Breast Reconstruction and Contralateral Augmentation

  • Kim, Soo Jung;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제44권5호
    • /
    • pp.413-419
    • /
    • 2017
  • Background In breast reconstruction using implants after unilateral mastectomy, it is challenging to create a natural, ptotic contour, and asymmetry is a potential drawback. To achieve breast symmetry and an ideal shape for both breasts, we performed contralateral augmentation in patients undergoing breast reconstruction with implants. Methods Patients underwent unilateral mastectomy and 2-stage reconstruction. During the second stage of the procedure, contralateral augmentation mammoplasty was performed. Preoperatively, we obtained the patients' demographic information, and we then assessed breast volume, the volume and dimensions of the inserted implants, and complications. Breast symmetry was observed by the surgeon and was assessed by measuring the disparity between the final volume of each breast. Results Contralateral augmentation was performed in 52 cases. When compared to patients who did not undergo a contralateral balancing procedure, patients who received contralateral augmentation were younger, thinner, and had smaller breasts. During implant selection for contralateral augmentation, we chose implants that were approximately 1 cm shorter in width, 1 level lower in height, and 1 or 2 levels lower in projection than the implants used for reconstruction. The postoperative breast contours were symmetric and the final volume discrepancy between each breast, which was measured by 3-dimensional scanning, was acceptable. Conclusions We demonstrate that contralateral augmentation can be recommended for patients who perceive their breasts to be small and not beautiful in order to achieve an ideal and beautiful shape for both breasts. Furthermore, this study offers guidelines for selecting the implant that will lead to the optimal aesthetic outcome.

Transaxillary Capsulorrhaphy with Reimplantation to Correct Bottoming-Out Deformity in Breast Mycobacterial Periprosthetic Infection: A Case Report with Literature Review

  • Tsung-Chun Huang;Jian-Jr Lee;Kuo-Hui Yang;Chia-Huei Chou;Yu-Chen Chang
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.557-562
    • /
    • 2023
  • Augmentation mammoplasty is one of the most popular cosmetic surgeries, but there is a high reoperation rate (29.7%) commonly due to capsular contracture, implant malpositioning, infection, and unsatisfactory size. Although infection only accounts for 2% of cases, its management is very challenging, especially with nontuberculous mycobacteria (NTM) infection. Breast prosthetic NTM infection is a rare but is a disastrous condition with an incidence of approximately 0.013%. Immediate salvage reimplantation is usually not suggested, and most studies recommend a gap of 3 to 6 months after combination antibiotics therapy before reimplantation. However, delayed reimplantation often leads to great psychological stress and struggle between the doctor and patient. We present the case report of successful reimplantation in treating prosthetic NTM infections in a 28-year-old female. We discuss a novel technique "transaxillary capsulorrhaphy" to correct the bottoming-out deformity. One year after the combination of antibiotics and surgery, the follow-up computed tomography scan showed complete remission of NTM without recurrence. We discuss the surgical technique in detail. The 1-year follow-up assessment (photos and dynamic video) revealed good cosmesis and reliable correction using the new technique. This report is the first formal description and discussion of one-stage reimplantation following NTM infections. Transaxillary capsulorrhaphy allows for a successful salvage operation when an implant is displaced. This approach provides highly favorable result in eastern women undergoing revision augmentation mammoplasty. This study reflects level of evidence V, considering opinions of respected authorities based on clinical experience, descriptive studies, or reports of expert committees.

The Efficacy of Simultaneous Breast Reconstruction and Contralateral Balancing Procedures in Reducing the Need for Second Stage Operations

  • Smith, Mark L.;Clarke-Pearson, Emily M.;Vornovitsky, Michael;Dayan, Joseph H.;Samson, William;Sultan, Mark R.
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.535-541
    • /
    • 2014
  • Background Patients having unilateral breast reconstruction often require a second stage procedure on the contralateral breast to improve symmetry. In order to provide immediate symmetry and minimize the frequency and extent of secondary procedures, we began performing simultaneous contralateral balancing operations at the time of initial reconstruction. This study examines the indications, safety, and efficacy of this approach. Methods One-hundred and two consecutive breast reconstructions with simultaneous contralateral balancing procedures were identified. Data included patient age, body mass index (BMI), type of reconstruction and balancing procedure, specimen weight, transfusion requirement, complications and additional surgery under anesthesia. Unpaired t-tests were used to compare BMI, specimen weight and need for non-autologous transfusion. Results Average patient age was 48 years. The majority had autologous tissue-only reconstructions (94%) and the rest prosthesis-based reconstructions (6%). Balancing procedures included reduction mammoplasty (50%), mastopexy (49%), and augmentation mammoplasty (1%). Average BMI was 27 and average reduction specimen was 340 grams. Non-autologous blood transfusion rate was 9%. There was no relationship between BMI or reduction specimen weight and need for transfusion. We performed secondary surgery in 24% of the autologous group and 100% of the prosthesis group. Revision rate for symmetry was 13% in the autologous group and 17% in the prosthesis group. Conclusions Performing balancing at the time of breast reconstruction is safe and most effective in autologous reconstructions, where 87% did not require a second operation for symmetry.

Contracted Nose after Silicone Implantation: A New Classification System and Treatment Algorithm

  • Kim, Yong Kyu;Shin, Seungho;Kang, Nak Heon;Kim, Joo Heon
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.59-64
    • /
    • 2017
  • Background Silicone implants are frequently used in augmentation rhinoplasty in Asians. A common complication of silicone augmentation rhinoplasty is capsular contracture. This is similar to the capsular contracture after augmentation mammoplasty, but a classification for secondary contracture after augmentation rhinoplasty with silicone implants has not yet been established, and treatment algorithms by grade or severity have yet to be developed. Methods Photographs of 695 patients who underwent augmentation rhinoplasty with a silicone implant from May 2001 to May 2015 were analyzed. The mean observation period was 11.4 months. Of the patients, 81 were male and 614 were female, with a mean age of 35.9 years. Grades were assigned according to postoperative appearance. Grade I was a natural appearance, as if an implant had not been inserted. Grade II was an unnatural lateral margin of the implant. Clearly identifiable implant deviation was classified as grade III, and short nose deformation was grade IV. Results Grade I outcomes were found in 498 patients (71.7%), grade II outcomes in 101 (14.5%), grade III outcomes in 75 (10.8%), and grade IV outcomes in 21 patients (3.0%). Revision surgery was indicated for the 13.8% of all patients who had grade III or IV outcomes. Conclusions It is important to clinically classify the deformations due to secondary contracture after surgery and to establish treatment algorithms to improve scientific communication among rhinoplasty surgeons. In this study, we suggest guidelines for the clinical classification of secondary capsular contracture after augmentation rhinoplasty, and also propose a treatment algorithm.

The Clinical Implications of Poly Implant Proth$\grave{e}$se Breast Implants: An Overview

  • Wazir, Umar;Kasem, Abdul;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • 제42권1호
    • /
    • pp.4-10
    • /
    • 2015
  • Mammary implants marketed by Poly Implant Proth$\grave{e}$se (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Proth$\grave{e}$se", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

Reducing pain and opioid consumption after body contouring of the breast by application of a perioperative nerve block: a systematic review

  • Asserson, Derek B.;Sahar, David E.
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.361-365
    • /
    • 2021
  • Background Pain in the postoperative body contouring patient has traditionally been managed with narcotic medication. In an effort to minimize side effects and prevent addiction, plastic surgeons are searching for novel ways to provide adequate analgesia, one of which is nerve blocks. This study was conducted with a meta-analysis that evaluates the efficacy of these blocks for patients who undergo breast surgery. Methods A search of the PubMed/MEDLINE database for articles including the terms "post-operative analgesia" OR "postoperative pain management" AND "in plastic surgery" OR "in cosmetic surgery" OR "in elective surgery" in February 2019 generated five studies on elective breast augmentation and reduction mammoplasty that reported pain scores and quantities of opioids consumed. Independent samples t-tests, one-way analysis of variance, and a random effects model were implemented for evaluation. Results A total of 317 patients were identified as having undergone body contouring of the breast, about half of which received a nerve block. Pain scores on a 1-10 scale and opioid dose-equivalents were calculated. Those who were blocked had an average score of 2.40 compared to 3.64 for those who did not (P<0.001), and required an average of 5.20 less narcotic doses (P<0.001). Pain relief following subpectoral augmentation was best achieved with type-II blocks as opposed to type-I and type-II with serratus plane (P<0.001). Conclusions The opioid epidemic has extended to all surgical specialties. Implementation of a nerve block seems to be an efficacious and cost-effective mechanism to not only help with post-operative pain, but also lower the need for narcotics, especially in subpectoral augmentation.

Breast Auto-Augmentation: A Versatile Method of Breast Rehabilitation-A Retrospective Series of 107 Procedures

  • Kirwan, Laurence;Wazir, Umar;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • 제42권4호
    • /
    • pp.438-445
    • /
    • 2015
  • Background Breast auto-augmentation (BAA) using an inferior pedicle dermoglandular flap aims to redistribute the breast tissue in order to increase the fullness in the upper pole and enhance the central projection of the breast at the time of mastopexy in women who want to avoid implants. The procedure achieves mastopexy and an increase in breast volume. Methods Between 2003 and 2014, 107 BAA procedures were performed in 53 patients (51 bilateral, 2 unilateral and 3 reoperations) with primary or secondary ptosis of the breast associated with loss of fullness in the upper pole (n=45) or undergoing explantation combined with capsulectomy (n=8). Six patients (11.3%) had prior mastopexy and 2 (3.7%) patients had prior reduction mammoplasty. The mean patients' age was 41 years (range, 19-66 years). All patients had preoperative and postoperative photographs and careful preoperative markings. Follow-up ranged from 6 months to 9 years (mean, 6.6 months). Results The range of elevation of the nipple was from 6 to 12 cm (mean, 8 cm). The wounds healed completely with no complications in 50 (94.3%) patients. Three patients had complications including 2 (3.7%) hematomas and 1 (1.9%) partial necrosis of the nipple-areola complex. Three (5.7%) patients were dissatisfied with the level of mastopexy achieved underwent a further procedure. No patient complained of scar hypertrophy. Conclusions BAA is a versatile technique for women with small breasts associated with primary or secondary ptosis. It is also an effective technique for the salvage of breasts after capsulectomy and explantation.

Capsular Contracture after Breast Augmentation: An Update for Clinical Practice

  • Headon, Hannah;Kasem, Adbul;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.532-543
    • /
    • 2015
  • Capsular contracture is the most common complication following implant based breast surgery and is one of the most common reasons for reoperation. Therefore, it is important to try and understand why this happens, and what can be done to reduce its incidence. A literature search using the MEDLINE database was conducted including search terms 'capsular contracture breast augmentation', 'capsular contracture pathogenesis', 'capsular contracture incidence', and 'capsular contracture management', which yielded 82 results which met inclusion criteria. Capsular contracture is caused by an excessive fibrotic reaction to a foreign body (the implant) and has an overall incidence of 10.6%. Risk factors that were identified included the use of smooth (vs. textured) implants, a subglandular (vs. submuscular) placement, use of a silicone (vs. saline) filled implant and previous radiotherapy to the breast. The standard management of capsular contracture is surgical via a capsulectomy or capsulotomy. Medical treatment using the off-label leukotriene receptor antagonist Zafirlukast has been reported to reduce severity and help prevent capsular contracture from forming, as has the use of acellular dermal matrices, botox and neopocket formation. However, nearly all therapeutic approaches are associated with a significant rate of recurrence. Capsular contracture is a multifactorial fibrotic process the precise cause of which is still unknown. The incidence of contracture developing is lower with the use of textured implants, submuscular placement and the use of polyurethane coated implants. Symptomatic capsular contracture is usually managed surgically, however recent research has focussed on preventing capsular contracture from occurring, or treating it with autologous fat transfer.

Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design

  • Myung, Yujin;Lee, Jong-Gu;Cho, Maenghyo;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.386-389
    • /
    • 2019
  • The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.

Transaxillary Subpectoral Placement of Cardiac Implantable Electronic Devices in Young Female Patients

  • Oh, Joo Hyun;Kim, Chae Min;Song, Seung Yong;Uhm, Jae Sun;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.34-41
    • /
    • 2017
  • Background The current indications of cardiac implantable electronic devices (CIEDs) have expanded to include young patients with serious cardiac risk factors, but CIED placement has the disadvantage of involving unsightly scarring and bulging of the chest wall. A collaborative team of cardiologists and plastic surgeons developed a technique for the subpectoral placement of CIEDs in young female patients via a transaxillary approach. Methods From July 2012 to December 2015, subpectoral CIED placement via an axillary incision was performed in 10 young female patients, with a mean age of 25.9 years and mean body mass index of $20.1kg/m^2$. In the supine position, with the patient's shoulder abducted, an approximately 5-cm linear incision was made along one of the deepest axillary creases. The submuscular plane was identified at the lateral border of the pectoralis major, and the dissection continued over the clavipectoral fascia until the subpectoral pocket could securely receive a pulse generator. Slight upward dissection also exposed an entrance to the subclavian vein, allowing the cardiology team to gain access to the vein. One patient with dilated cardiomyopathy underwent augmentation mammoplasty and CIED insertion simultaneously. Results One case of late-onset device infection occurred. All patients were highly satisfied with the results and reported that they would recommend the procedure to others. Conclusions With superior aesthetic outcomes compared to conventional methods, the subpectoral placement of CIEDs via a transaxillary approach is an effective, single-incision method to hide operative scarring and minimize bulging of the device, and is particularly beneficial for young female or lean patients.