• Title/Summary/Keyword: audiometric

Search Result 41, Processing Time 0.04 seconds

Implementation of Multi-threading Ambulatory Speech Audiometric System (멀티스레딩 기법을 이용한 휴대용 어음청력검사 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Yoon, Tae-Ho;Lee, Sun-Ju;Lee, Seong-Taek;Lee, Jeong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1998_1999
    • /
    • 2009
  • 본 연구에서는 단일 청력검사 모듈에서 여러 가지 작업들을 동시에 운용할 수 있는 멀티스레딩 기법의 구현을 통하여, 청력검사 시스템에서 피검사자가 검사가 진행되는 동안 언제든지 응답 결과를 확인하거나 또는 수정할 수 있도록 하는 휴대용 어음청력검사 시스템을 구현하고자 하였다.

  • PDF

High-performance Digital Hearing Aid Processor Chip with Nonlinear Multiband Loudness Correction (비선형 다중채널 Loudness 교정을 위한 고성능 보청기 칩)

  • Park, Young-Cheol;Kim, Dong-Wook;Kim, Won-Ky;Park, Sang-Il
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.342-344
    • /
    • 1997
  • Owing to technical advances in very large-scale integrated circuits (VLSI), high-speed digital signal processing (DSP) chips become fast enough to allow for real-time implementation of hearing aid algorithms in units small enough to be wearable. In this paper, we present a digital hearing aid processor (DHAP) chip built around a general-purpose 16-bit DSP core. The designed DHAP performs a nonlinear loudness correction of 8 octave frequency bands based on audiometric measurements. By employing a programmable DSP, the DHAP provides all the flexibility needed to implement audiological algorithms. In addition, the has a low power feature and $5.410\times5.720mm^2$ dimensions that fit for wearable devices.

  • PDF

Impedance Audiometry in Children (학동기 아동의 Impedance Audiometry에 대한 연구)

  • 소진명;전승하;장혁순
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.4.2-4
    • /
    • 1979
  • Since Metz had employed the impedance audiometry in 1946, scholars have carried out many investigation. Brook, Jeger, Cooper reported and evaluated the clinical studies of impedance audiometry and its screening test. Recently, in Korea, a studies of impedance audiometry have been reported. We analysed 100 children aged between 7-16 years old who visited OPD of E.N.T. department with the complaints of the nasal obstruction and hard of hearing from Nov. 77-Feb. 79. Through the use of otoscope and impedance audiometry, we evaluated the types of tympanogram, static compliance and the acoustic reflex. This paper is dealing with the statistical study of impedance audiometric result and its literature.

  • PDF

A Study on Diagnostic Criteria of Noise-Induced Hearing Loss among Workers in an Iron Foundry (철강공장 근로자를 대상으로 살펴본 소음성 난청 진단기준에 관한 조사)

  • Kim, Ji-Yong;Lim, Hyun-Sul;Cheong, Hae-Kwan;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.371-386
    • /
    • 1993
  • This study was carried out to evaluate diagnostic criteria of noise-induced hearing loss (NIHL) among-workers in an iron foundry. Of 1,093 workers under the observation of noise-specific health examination, 184 workers were selected by way of first and second screening audiometric examination. A questionnaire survey, otological examinations, Rinne test and audiometric test were performed and the results were as follows ; The degree of hearing impairment in the left ear was more severe than in the right ear (p<0.05). The difference between hearing threshold of the first and the second hearing test at 1,000 Hz was about 5 dB with a narrow range of deviations while the difference at 4,000 Hz was about -7 dB with a wide range. Of the total study workers, 84.8% were tested within 15 hours away from noise exposure, and the rest after 16 hours. This study has identified that mean hearing loss at 4,000 Hz showed a significant statistical difference among the two study groups while mean hearing loss by 4-divided classification did not. The same phenomena were observed between the group with and without tinnitus and between the group with and without difficulty in hearing (p<0.05). Among 184 workers, 10 workers (5.4%) diagnosed as NIHL by old diagnostic criteria in contrast to 150 workers diagnosed as NIHL by the new diagnostic criteria. There was a significant difference between the two groups in the average hearing loss at 4,000 Hz and 4-divided classification (p<0.01), but there were no significant differences in age, the duration of employment, blood pressure and the duration wearing the personal hearing protector (p>0.05). If we apply Early Loss Index (ELI) method, some workers in younger age group diagnosed as NIHL by the new diagnostic criteria were fallen into within the normal range. In the mean time older age group show reverse results in contrast to the above finding. It is too early to confirm the value of the usage of the new diagnostic criteria in hearing examination. Further study is called for to verify the value of this criteria.

  • PDF

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

A Study on the Hearing Disturbance Based on the Classification of Hazardous Occupation (위험직종(危險職種) 분류(分類)에 따른 난청(難聽)의 고찰(考察))

  • Park, Young-Il
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.122-127
    • /
    • 1985
  • The basis for determining hearing disturbance adopted by the Life Insurance Industry is the loss of hearing power above 80 db on either or both sides, in accordance with the divide sixth method of audiometric test. Different types of small-to-medium-sized enterprises were chosen for the study of the extent of loss and the power of hearing. The following are the findings: 1. The disturbance percentage found among the types of occupation and different levels of age was found to be higher as the subject's ages increased. 2. The heavier the workload and the noisier the environment, the higher the percentage of disturbance. The average percentage of the subjects turned out to be 24.35%. Those engaged in sawing and wood-work showed 49%. Those engaged in machinery and equipment for transportation accounted for 42.6%. Those engaged in the metal products occupied 39.6%. The disturbance percentage among those engaged in such noisy works as press, pipe and sawing showed 32.52%. 28.46% of those workers with three to four years employment turned out to be disturbed in hearing. Of these, a high percentage of 43.9% showed disturbance in conversation or talk. 3. No hearing loss due to occupation beyond the Life Insurance standard of 80 db was found; therefore, the present status poses no problem. Constant attention, however, is needed.

  • PDF

Exposure to Noise on Railroad Operators (철도 차량 운전원의 소음노출 특성)

  • Lee, Sang-Yun;Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2008
  • Personal noise exposure was assessed in railroad operators working in 40 operation units including the Gyeongbu line, Honam line, and Janghang line between 2004 and 2006. 8-hour TWA were assessed based on the MOL (Ministry of Labor) guideline on noise evaluation, and 17% of these measurements exceeded 85 dBA while 70% were over 80 dBA. When the ACGIH TLV is adopted, 40% of measurements were over TLV (85 dBA). The noise exposure risk of railroad operators was higher for diesel locomotive operation and longer operational distances; in addition, the risk was higher for passenger car operation compared to freight car driving. Given that in Korea, over the past 30 years diesel locomotives have provided most of the railway's motive power and that hearing protective equipment is not likely to be used by workers during operation, railroad operators are at a high risk of noise-induced hearing loss. The result of audiometric test among 568 railroad operators showed that 32.6% of those tested had a hearing threshold shift of more than 40 dB. In conclusion, this study calls for more fundamental measures including noise control countermeasures within the operation areas, development of equipment that generates less noise and adopting limitation on the operation distance for a work shift.

Stenver's Radiographic Assessment of the Multichannel Cochlear Implant (Stenver's 법을 이용한 인공와우관 환자의 촬영에 관한 연구)

  • Kweon, Dae-Cheol;Jung, Hong-Ryang;Kim, Myeong-Soo;Lim, Cheong-Hwan;Kim, Jeong-Koo;Kim, Dong-Sung;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.35-37
    • /
    • 2002
  • To assess the new multichannel cochlear implant by radiography in Stenver's projection, because MRI generates artifacts, inducing an electrical current and causing device magnetization. CT is relatively expensive and the metal electrodes scatter the image. Multichannel cochlear implant insertion using the multichannel cochlear implant device. Patients underwent postoperative radiography of their implants. The radiographs were obtained in a Stenver's. The insertion depth of the implant was measured on the radiographs and the results were correlated with the surgical results of insertion depth and with audiometric tests. Patients a correct inserted electrode was found, while in patient complications concerning the electrode were noticed. Radiographs in the Stenver's projection are sufficient for the postoperative assessment of the multichannel cochlear implant device and an exact evaluation of the insertion depth.

  • PDF

Two-stage Ear Reconstruction with Canaloplasty in Congenital Microtia (외이도성형술을 병행한 선천작은귀증의 두단계 재건)

  • Kim, Jong Yeop;Cho, Byung Chae;Lee, Sang Heun
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.53-60
    • /
    • 2006
  • The current authors performed two-stage ear reconstruction of microtia using autogenous costal cartilage combined with canaloplasty of the acoustic meatus in a team approach. In the first stage, lobule transposition, fabrication of the cartilage framework, and implantation of the framework were peformed. In the second stage, elevation of the auricle, cartilage graft for posterior auricular sulcus, coverage with the mastoid fascia flap and skin graft, and concha excavation were performed. The canaloplasty was combined simultaneously in patients with radiologic and audiometric evidence of cochlear function in the second stage. A total of 36 consecutive patients with congenital microtia were treated from 1998 to 2003. Among them, 27 patients(male: 18, female: 9) ranging from 7 to 43 years old were combined with canaloplasty. The follow-up period was one year to 5 years. Thirteen patients exhibited improved hearing over 30 dB PTA(pure tone average), 9 patients below 30 dB, and 5 patients with no improvement. Complications related to the canaloplasty were chronic drainages of the auditory meatus and meatal stenosis. Lobule type deformity combined with the canaloplasty showed higher complications than concha type. Therefore, in the lobule type, meticulous manipulation is necessary to reduce complications after the canaloplasty.

Clinical Observation on Hearing Impairment in Diabetes Mellitus Patients (당뇨병 환자의 청각장애에 대한 관찰)

  • 지정민;송재권
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.3.3-3
    • /
    • 1977
  • For a year from Jan. 1976 to Dec. 1976, the authors have performed the clinical observation in accordance with audiometric test and clinical findings of 43 cases (male 25: female 18) who were diagnosed of diabetes mellitus in diabetic clinic of our hospital. The results are as follows; 1) Eight of 43 cases reveal hearing impairment, and almostly abrupt drop or descending in hearing types. 2) The incidence of hearing impairment is higher in middle and older age group. 3) Hearing impairment has not related to duration of the disease but blood sugar level and total serum cholesterol level in some extent. 4) The incidence of hearing impairment is higher in cases accompanied by complications such as retinopathy, hypertension, neuropathy etc. 5) In etiology of hearing impairment, multiple factors seem to be concerned.

  • PDF