• 제목/요약/키워드: attenuation measurement

검색결과 391건 처리시간 0.023초

Dose Calculation of Photon Beam with Wedge Filter for Radiation Therapy Planning System

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.41-41
    • /
    • 2003
  • Purpose: Even if the wedge filter is widely used for the radiation therapy to modify the photon beam intensity, the wedged photon beam dose calculation is not so easy. Radiation therapy planning systems (RTPS) have been used the empirical or semi-analytical methods such as attenuation method using wedge filter parameters or wedge filter factor obtained from measurement. However, these methods can cause serious error in penumbra region as well as in edge region. In this study, we propose the dose calculation algorithm for wedged field to minimize the error especially in the outer beam region. Materials and Method: Modified intensity by wedge filter was calculated using tissue-maximum ratio (TMR) and scatter-maximum ratio (SMR) of wedged field. Profiles of wedged and non-wedged direction was also used. The result of new dose calculation was compared with measurement and the result from attenuation method. Results: Proposed algorithm showed the good agreement with measurement in the high dose-gradient region as well as in the inner beam region. The error was decreased comparing to attenuation method. Conclusion: Although necessary beam data for the RTPS commissioning was increased, new algorithm would guarantee the improved dose calculation accuracy for wedged field. In future, this algorithm could be adopted in RTPS.

  • PDF

초음파법에 의한 스프링강의 재질평가에 관하여 (On Evaluation of Material Properties in Spring Steels by Measurement of Ultrasonic Techniques)

  • 김상수;하경준;김선진
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.41-46
    • /
    • 2002
  • The general purpose of this paper is Evaluation of material properties in spring steels by investigate correlation between ultrasonic attenuation and virker's hardness, charpy impact properties, microstructures. The three test speciments of the $490{\times}90 mm$ plates and 20 mm thick are used but differ in heat treatment, one is rolled plate, the second is quenched and then tempered, and the third is quenched. ultrasonic attenuation were obtained at fifteen locations on the plates. In order to investigate the correlation between hardness ( especially, HV ) and the attenuation, the virker's hardness and the microstructures were observed for three spring steels. also the charpy impact test were carried out at the room temperature in order to investigate the relationship between impact properties and the attenuation. The experimental results obtained from three different spring related to the heat treatment conditions and attenuation coefficient is increased with increasing the hardness(HV). Ultrasonic attenuation coefficients have shawn are ability to distinguish among spring steels.

  • PDF

PXI를 이용한 LabVIEW기반 해양퇴적물의 음향특성 측정시스템 개발 (Implementation of Acoustic Properties Measurement System Based on LabVIEW Using PXI for Marine Sediment)

  • 박기주;김대철;이광수;배성호;김길영
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권3호
    • /
    • pp.216-222
    • /
    • 2015
  • 기존의 자동음파전달속도 측정시스템을 이용하여 해양퇴적물의 음향특성을 측정하는 경우 최초도달신호시간의 결정에 발생하는 오류와 측정 절차의 번거로움 등의 몇 가지 문제점들이 존재한다. 이러한 문제점을 개선하기 위하여 PXI모듈을 이용한 LabVIEW기반의 측정 시스템을 개발하였다. 새로운 측정시스템을 검증하기 위해 동일한 시료와 실험환경에서 기존 시스템과 병행하여 측정하였다. 그 결과 1~2%의 음파전달속도 측정오차를 보였으며 음파감쇠 역시 기존 시스템과 유사한 결과 값을 도출하였다. 새로이 개발된 PXI(PCI eXtentions for Instrumentation)를 이용한 LabVIEW 기반 음향특성 측정시스템은 퇴적물의 음향특성을 보다 신속하고 효율적으로 측정할 수 있고 측정 자료뿐만 아니라 분석된 신호의 원시자료에 대해서도 지속적인 데이터베이스를 구축할 수 있다.

초음파 C-Scan을 이용한 구조용 세라믹스의 기계적 특성평가 (Evaluation of Mechanical Properties of Structural Ceramics ($Al_{2}O_{3}$) Using the High Frequency Ultrasonic C - Scan)

  • 장영권
    • 비파괴검사학회지
    • /
    • 제9권2호
    • /
    • pp.18-24
    • /
    • 1989
  • Computer-aided high frequency ultrasonic is applied to aluminum oxide(85w%, 94w%, 96w%, and 99w%) MOR(modulus of rupture) samples to evaluate mechanical properties such as density variation, pore content, elastic modulus, shear modulus, and poisson's ratio. Ultrasonic wave velocity and attenuation measurement techniques were used as an evaluator of such properties. Pulse-echo C-Scan images with different fate setting method using 50MHz center frequency 1 inch focal length transducer allows evaluation of density variation and pore content. Elastic modulus calculated with the relation of density and ultrasonic velocity. It shows good reliability as compared with resonance method. Sintered density variation of $0.025g/cm^{3}$, that is 0.6% of theoretical density in $Al_{2}O_{3}$ samples can be observed by ultrasonic velocity measurement. Attenuation measurement method qualitatively agree with 4-point fracture testing result concerning of porosity content.

  • PDF

격자구조로 배열된 실린더에 의한 음파감쇠 (Sound Attenuation by Cylinders Arranged in a Lattice)

  • 김현실;김상렬;김재승;김봉기;이성현
    • 한국소음진동공학회논문집
    • /
    • 제21권11호
    • /
    • pp.1013-1019
    • /
    • 2011
  • Sound attenuation of periodically arranged cylindrical rods is studied numerically and experimentally. Cross section of the cylinder is circular and arrays are in a square lattice. Cylinders are made of steel, and consist of five groups with different diameters from 27.2 mm to 48 mm. Each group has 5 rows, while number of cylinders in a row varies from 17 to 31. The area filling fraction is about 60~61 %, which leads to the stop bandgap(2.9 kHz ~ 8.4 kHz). Sound attenuation is computed using two-dimensional BEM, and measurement is done by using a speaker and microphones in a semi-anechoic room. Comparison of the results by BEM and experiment shows that attenuation spectra are qualitatively in agreement, although experiment gives higher attenuations than BEM. After results by BEM are scaled up in accordance with cylinder diameter, it is observed that attenuation curves are in good agreement, which confirms that analysis by BEM is done correctly. It is also found that the measured bandgaps are shifted toward lower frequency by 0.5 kHz ~ 1.2 kHz, when compared to the predictions obtained from infinitely repeated two-dimensional cylinder arrays.

초음파 감쇠계수 주정에 있어서 빔 형태의 보정에 관한 연구 (A Study on the Correction of Beam Pattern for the Ultrasonic Attenuation Coefficient Estimation)

  • 김기욱;최흥호;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권1호
    • /
    • pp.41-48
    • /
    • 1987
  • In estimating the freguency-dependent attenuation coefficient, we analyzed the range-dependent ultrasonic beam and proposed the method of calculating the experimental equation of beam pattern in order to reduce the error on the influence of beam pattern. These experimental equations are divided into the spectral centroid and the spec ural standard deviation slope according to axial propagation length. These are repnesented by the first-order equation in the near field of the beam and the second- order eqLlatlon In the far field. In order to prove the validity of this method, the attenuation coefficients of the non-corrected ease and the corrected case are compared. Using the reflected signal from acryle plate, the attenuation coefficients were estimated by the spectral shift method ann the spectral difference method. The result shows attenuation coeffi talents after correction are better than attenuation coefficients before correction. And this method can be applied In vivo measurement.

  • PDF

위상 스펙트럴 차분법에 의한 초음파 감쇠 계수의 측정 (Measurement Ultrasound Attenuation by Using Phase Spectral Difference Method)

  • 민용기;최종호;이강호;최종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1243-1246
    • /
    • 1987
  • To characterize the biological tissues, the new methods to measure the frequency dependent attenuation are presented in this paper. In general, ultrasonic phase information was assumed by linear function of the frequency. But, the minimum phase function which characterizes the frequency dispersion of tissue was derived in [l]. It is very significant to measure the attenuation by using the minimum phase function to characterize the frequency dispersion of tissue. Therefore, a more efficient method measuring the frequency dependent attenuation are proposed by using the estimated sound velocity and polarity of reflected signal. To verify the algorithms, pulse reflection experiments are performed.

  • PDF

초음파법에 의한 저탄소강의 페라이트 결정립 크기 측정 (Measurement of Ferrite Grain Size by Ultrasonic Method in Low Carbon Steel)

  • 홍순택;권숙인;주웅용
    • 열처리공학회지
    • /
    • 제12권2호
    • /
    • pp.157-165
    • /
    • 1999
  • Grain size of steels is one of the most important parameters which influence yield strength and fracture toughness. Ultrasonic wave propagating in polycrystalline materials is mostly attenuated by scattering at grain boundary. Effect of ultrasonic attenuation on average ferrite grain size of carbon steels with tensile strength $40{\sim}60kgf/mm^2$ consisting of multi phases such as ferrite + pearlite and ferrite + pearlite + bainite was evaluated. The attenuation of these steels rapidly increased with average ferrite grain diameter. Average ferrite grain diameter ($D_{av}$, ${\mu}m$) could be expressed as $1.79+22.97*a^{1/2.03}$, where a is attenuation with unit of nepers/cm. From this study, it was confirmed that nondestructive ultrasonic method could be used in measuring average ferrite grain size indirectly.

  • PDF

차기 군위성체계의 디지털 위성중계기를 이용한 상향링크 강우감쇠에 대한 향상된 보상방안 연구 (A Study on Advanced Satellite Uplink Rain Attenuation Compensation using Digital Transponder of Next Military Satellite)

  • 김정호;이수현;김봉수;이창영;송영중
    • 한국통신학회논문지
    • /
    • 제35권11B호
    • /
    • pp.1696-1703
    • /
    • 2010
  • 군 위성통신에 대한 수요의 증가와 기존에 사용되어온 주파수 대역의 포화로 인하여, Ka 및 EHF 대역의 광대역 주파수자원을 이용한 위성통신체계의 개발요구가 확대되고 있다. 이와 관련하여 Ka 대역 이상의 주파수자원을 이용한 위성통신 시스템의 활성화에 기장 큰 어려움인 강우감쇠 극복에 대한 연구가 활발히 이루어지고 있다. 차기 군위성통신체계의 위성중계기에는 위성링크에 대한 디지털신호처리(스위칭/방송/간섭제거/ALC 등)가 가능한 디지털중계기가 탑재될 예정이다. 본 논문에서는 탑재될 디지털중계기의 부채널별 전력검출기능과 기존 단말의 변조비콘수신장치를 이용한 검출값 수신기능을 이용하여 위성망 차원에서의 강우감쇠 보상 알고리즘을 제시한다. 새롭게 제시된 알고리즘은 기존에 사용된 하향링크의 위성 비콘신호에 의한 간접측정과 상향링크전력제어장치를 사용한 강우감쇠 보상방안보다 기술적/경제적으로 보다 향상된 강우감쇠 보상방안을 제시한다.

초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제20권1호
    • /
    • pp.18-26
    • /
    • 2000
  • 화력발전소 보일러 고온배관인 주증기관, 헤드 및 증기드럼 등의 설비들은 장시간동안 고온고압의 가혹한 조건으로 운전됨에 따라 크리프손상에 의해 열화되고 있다. 이들 설비의 크리프손상측정에 적용되는 종래의 비파괴기법인 레프리카법, 전기저항법 및 경도법 등은 복잡한 측정절차 및 접근성, 검사결과의 신뢰도 및 측정정도 등 여러가지면에서 단점이 많다. 따라서 본 논문에서는 화력발전소 주요 고온배관에서 발생되는 경년열화인 크리프손상에 대한초음파 측정연구를 수행한 결과로서, 고온배관재료인 Cr-Mo강의 크리프 인공열화재를 대상으로 이들에 대한 크리프손상 상태별 초음과 음속(sound velocity) 및 감쇠(attenuation)의 초음파 신호특성을 평가하였다.

  • PDF