Feed Rate Control for the Head-Feed Thresher (수급식탈곡기(穗給式脱穀機)의 공급율(供給率) 제어(制御)(II) -제어시스템 설계 및 시뮬레이션-)

  • Choi, Y.S.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.110-122
    • /
    • 1990
  • This study was undertaken to develop the feed rate control system for the head feed thresher by making use of the microprocessor and to evaluate the response of the system to a various threshing conditions. The control unit was composed of one-board microcomputer. The speed of the wet-paddy feeding chain was controlled by dc moter with PI controller. It was used the adaptive control method to maintain the constant feed rate regardless of the fed rice varieties. The sliding type potentiometer was used as the feed rate sensor, which was attached on the sheaf-holding apparatus. The mathematical models of the system components were derived and computer simulation was developed for investigating the parameters affecting on control performance and for estimating the response of the system. A one-board microcomputer-based feed rate control system developed in this study was properly functioned and assessed as adequate for the feed rate control system of the head feed thresher. Based on the simulation for the bundle feed, it was anticipated that the lower setting value of the cylinder speed(RL) is to be set higher than the limiting operational speed. In addition, the higher setting value of the cylinder speed(RH) is to be set lower than the limiting cylinder speed for threshing. The computer simulation for the continuous spread feed showed that the lower the setting value of straw layer thickness(LL) was set, the shorter the correction time. However, if too low LL may be established, the feed rate could not reach to its desired rate.

  • PDF

A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer (Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究))

  • Suh, W.M.;Min, Y.B.;Yoon, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

Analysis of multi-layered Surface with Glow Discharge-Mass Spectrometry (글로우방전 질량분석법을 이용한 다층박막의 표면 분석)

  • Pak, Yong-Nam;Lee, Gae-Ho;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.357-361
    • /
    • 1997
  • A Griemm type Glow Discharge cell is attached to a commercial quadrapole based ICP-MS and used for the analysis of surface analysis. By employing 2.0mm diameter, mode and proper experimental conditions, several layers of few ${\mu}m$ thickness are analysed within 30 minutes. Multi-layers of Cu-Ni, Fe-Ni are analyzed with the resolution of 10nm by GDMS. Proper experimental conditions make a flat bottom crater shape and good resolution for multi-layer depth profile study.

  • PDF

Monitoring of wind turbine blades for flutter instability

  • Chen, Bei;Hua, Xu G.;Zhang, Zi L.;Basu, Biswajit;Nielsen, Soren R.K.
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.2
    • /
    • pp.115-131
    • /
    • 2017
  • Classical flutter of wind turbine blades indicates a type of aeroelastic instability with fully attached boundary layer where a torsional blade mode couples to a flapwise bending mode, resulting in a mutual rapid growth of the amplitudes. In this paper the monitoring problem of onset of flutter is investigated from a detection point of view. The criterion is stated in terms of the exceeding of a defined envelope process of a specific maximum torsional vibration threshold. At a certain instant of time, a limited part of the previously measured torsional vibration signal at the tip of blade is decomposed through the Empirical Mode Decomposition (EMD) method, and the 1st Intrinsic Mode Function (IMF) is assumed to represent the response in the flutter mode. Next, an envelope time series of the indicated modal response is obtained in terms of a Hilbert transform. Finally, a flutter onset criterion is proposed, based on the indicated envelope process. The proposed online flutter monitoring method provided a practical and direct way to detect onset of flutter during operation. The algorithm has been illustrated by a 907-DOFs aeroelastic model for wind turbines, where the tower and the drive train is modelled by 7 DOFs, and each blade by means of 50 3-D Bernoulli-Euler beam elements.

Finite element modelling and design of partially encased composite columns

  • Chicoine, Thierry;Tremblay, Robert;Massicotte, Bruno
    • Steel and Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.171-194
    • /
    • 2002
  • In this paper, the behaviour of axially loaded partially encased composite columns made with light welded H steel shapes is examined using ABAQUS finite element modelling. The results of the numerical simulations are compared to the response observed in previous experimental studies on that column system. The steel shape of the specimens has transverse links attached to the flanges to improve its local buckling capacity and concrete is poured between the flanges only. The test specimens included 14 stubcolumns with a square cross section ranging from 300 mm to 600 mm in depth. The transverse link spacing varied from 0.5 to 1 times the depth and the width-to-thickness ratio of the flanges ranged from 23 to 35. The numerical model accounted for nonlinear stress-strain behaviour of materials, residual stresses in the steel shape, initial local imperfections of the flanges, and allowed for large rotations in the solution. A Riks displacement controlled strategy was used to carry out the analysis. Plastic analyses on the composite models reproduced accurately the capacity of the specimens, the failure mode, the axial strain at peak load, the transverse stresses in the web, and the axial stresses in the transverse links. The influence of applying a typical construction loading sequence could also be reproduced numerically. A design equation is proposed to determine the axial capacity of this type of column.

MTM MEASUREMENT OF THE LENS ON THE KITSAT-1 EARTH IMAGING SYSTEM (우리별 인공위성의 지상 촬영 장치에 쓰여진 렌즈의 MTF 측정)

  • 류광선;민경욱;유상근
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.320-326
    • /
    • 1994
  • The KITSAT-1 (Auguse, 1992) and the KITSAT-2(September, 1993) were successfully launched and operated by the SatRec(Satellite Research Center). Both carry the CCD cameras to monitor the image of the earth. We used the camera bench type automatic equipment in the KSRI(Korea Standards Research Institute) to measure the MTF(Modulation Transfer Function) value of the lens attached to the CCD camera. We measured the tangential MTF and the sagital MTF by varing the f-number and the field angle. According to the result, the light from a point source is focused within one pixel of the CCD chip when the f-number is smaller than 4.0, and the MTF value becomes smaller as the field angle increases.

  • PDF

Analysis on the Magnetic Field Distribution of Low-Tc Superconducting Power Supply Using Finite Element Method (유한요소법을 이용한 저온초전도전원장치의 자기장분포 해석)

  • Bae, Duck-Kweon;Yoon, Yong-Soo;Kim, Ho-Min;Ahn, Min-Cheol;Kim, Yeong-Sik;Han, Tae-Su;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.739-741
    • /
    • 2001
  • Magnetic field distribution of rotating flux type Low-Tc superconducting (LTS) power supply with respect to the applied current on exciters is investigated in detail by using Finite Element Method (FEM). LTS power supply consists of two exciters, a rotor, a stator and superconductor foil attached to the inner surface of the stator and LTS load. The current pumping of LTS power supply is induced by partial-quenching and recovery of superconductor foil. For this reason, magnetic flux density on superconductor foil must be sufficiently greater than the its critical magnetic density. In this analysis, the normal spot on superconductor foil appears more than 10A of excitation current. The results of this analysis are calculated and compared with the experimental results.

  • PDF

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

Histopathologic Lesion of Mannheimia haemolytica pneumonia in calves (송아지에서 발생한 Mannheimia haemolytica 폐렴의 병리조직학적 소견)

  • Jean, Young Hwa;Roh, In Soon;Lee, Kyung Hyun;Lee, Kyung Woo;Lee, Hee Soo
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.3
    • /
    • pp.317-321
    • /
    • 2008
  • Four 5 month old calves were died after showing respiratory distress after long-distance transportation at winter season. They were diagnosed as fibrinous lobar pneumonia caused by Mannheimia (M.) haemolytica. Grossly, lungs were attached onto the pleura by fibrin, with a rich yellowish fluid in thorax. The cut surface of the lung was showed marbled pattern of the reddish or greyish consolidation and widened interlobular septa by fibrin deposition. Histopathologically, parenchymal necrosis was delineated by a band of the degenerated inflammatory cells, and distended interlobular septa with serofibrinous exudates and vascular thrombosis with alveolar capillaries degeneration and abundant serofibrinous exudates in alveoli. M. hemolytica were isolated from all calves, and bovine viral diarrhea virus and parainfluenza type 3 virus in one calf were detected by RT-PCR. Thus, it was concluded that this case was diagnosed as pneumonic mannheimiosis suggested by complex infection with viruses after long-distance transportation and coldness.

Analysis of relationship between daily inflow rate fluctuation and surface wave transfer velocity in water treatment processes (일 유입유량 변동과 공정내 표면파 전파속도 상관성 분석)

  • Park, No-Suk;Lim, Seong-Eun;Kim, Seong-Su;Hwang, Jun-Sik;Jung, Nahm-Chung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.239-243
    • /
    • 2008
  • The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the outlet flow-rate from each process abruptly, and ultimately occur the detachment of the attached particles inside each unit process. Also, since it takes very short time for the surface wave occurred from the fluctuation of inlet flow to reach the latter processes, it is impossible for operators to cope with that stably. Therefore this study was conducted to suggest the methodology for accurately predicting the travel time of surface wave occurred from the fluctuation of inlet flow to reach the latter process. Through the experiment, which was carried out for the full-scale water treatment plants(capacity : 2,000m3/d), it could be confirmed that the flow rate fluctuation from equalization tank produce the surface wave. And the wave transfer velocity is a function of the hydraulic radius and the length of each open type tanks which are comprised in the latter processes.