• 제목/요약/키워드: atomic distribution

검색결과 827건 처리시간 0.028초

목재 유물 김젖개의 몬테카를로 방법을 이용한 감마선 조사 (Optimal Gamma Irradiation Using Monte Carlo Simulations on Wooden Cultural Properties, Gimjeotgae)

  • 윤민철;최종일;이윤종;임길성;이주운
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.95-100
    • /
    • 2012
  • In this study, there has been investigated the simulation of irradiation dose using Monte Carlo methodology for the biological control of wooden cultural property. In the evaluation of fungal contamination on wooden cultural properties, Cladosporium tenuissimum, Aspergillus versicolor, Penicillium sp. were mainly identified from the Gimjeotgae. But these microorganisms were completely inactivated by 20 kGy gamma-rays. For dosimetry simulation of wooden cultural properties, Monte Carlo methodology with MCNP was used. The radiation absorbed dose distribution was predicted at 8.2~18.9 kGy. These results show that irradiation is effective for biologic control of wooden cultural properties and Monte Carlo methodology is useful for non-destructive conservation and preservation of wooden cultural properties.

광섬유 임베디드 센서 기반 분포 모니터링 기술 (Distributed Monitoring Technology using Fiber-Optic Embedded Sensor)

  • 김영웅;김종열;류국빈;황영관;김현길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.617-619
    • /
    • 2022
  • 3D 프린팅 기술을 이용하여 광섬유가 내장된 임베디드 센서 구조물을 제조하였으며, 광주파수 반사 산란광 측정법 기반의 분포 센서 기술을 이용하여 대상 구조물에 인가된 스트레인 분포를 측정하였다. 측정된 분포 데이터는 대상 구조물 형상에 실시간 대입하여 3차원 시각화 표현하였다.

  • PDF

영상처리기반 감마선 분포탐지 효율 개선에 관한 연구 (The Study for Improved Efficiency of the Detection of Radiation Sources Distribution using Image Processing)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.780-781
    • /
    • 2016
  • 스테레오 감마선 공간 탐지장치는 감마선원을 탐지하고 그 결과를 바탕으로 2차원 영상분포를 측정한 후, 스테레오 카메라 기법을 적용하여 3차원 공간상에서 장치로부터 선원까지의 거리를 측정할 수 있도록 구현되었다. 본 논문에서는 영상처리 알고리즘을 통해 감마선 공간 탐지를 위한 스캔시간을 줄이고, 방사광 및 가시광 영상을 중첩한 후 스테레오 보정을 통해 3차원 가시화를 통한 감마선 분포 탐지 효율 개선을 위한 연구를 수행하였다. 탐지시험 결과 고속 탐지를 위한 알고리즘을 적용한다면 단일선원을 탐지할 때 약 30%이상의 탐지효율 개선하였으며, 3D 모니터를 통한 3차원 시각화 영상을 통해 공간상의 선원에 대한 분포를 확인하였다.

  • PDF

방사성 금속폐기물의 용융시 방사성 핵종(60Co, 137Cs)의 분배특성 (Distribution Characteristics of Radionuclies (60Co, 137Cs) During the Melting of Radioactive Metal Waste)

  • 민병연;최왕규;오원진;정종헌;강용
    • Korean Chemical Engineering Research
    • /
    • 제45권6호
    • /
    • pp.627-632
    • /
    • 2007
  • 원자력 시설 해체시 발생되는 금속성 폐기물의 용융 제염을 위한 기초 연구를 위해 아크 용융로를 사용하여 스테인레스강과 탄소강의 금속 폐기물 용융시 슬래그 종류, 농도, 염기도에 따라 $^{60}Co$, $^{137}Cs$ 핵종의 주괴, 슬래그, 분진 상으로 분배 특성을 살펴보았다. $^{60}Co$은 90% 이상 주괴상에 균질하게 분포되었으며, 슬래그 상에는 약 10% 미만으로 잔존하며 슬래그 조성에 따라 분배특성이 크게 영향을 받지 않았으나, 유동성이 좋은 염기성 슬래그 형성제가 포함된 슬래그에서는 영향을 받음을 알 수 있었다. $^{137}Cs$는 스테인레스강과 탄소강의 용융체로부터 완전히 제거되어 슬래그상과 분진상 상으로 분배됨을 알 수 있었다.

Experimental investigation of effective atomic numbers for some binary alloys

  • Sharma, Renu;Sharma, J.K.;Kaur, Taranjot;Singh, Tejbir;Sharma, Jeewan;Singh, Parjit S.
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1571-1574
    • /
    • 2017
  • In the present work, the gamma ray backscattering technique was used to determine the effective atomic numbers for certain binary alloys. With the help of a muffle furnace, the binary alloys were synthesized using the melt quenching technique with different compositions of $_{82}Pb$, $_{50}Sn$, and $_{30}Zn$. The intensity distribution of backscattered photons from radioactive isotope $^{22}Na$ (511 keV) was recorded with the help of GAMMARAD5 [$76mm{\times}76mm$ NaI(Tl) scintillator detector] and analyzed as a function of both atomic number and thickness of the target material. The effective atomic numbers for the same binary alloys were also computed theoretically using the atomic to electronic cross-section method with the help of the mass attenuation coefficient database of WinXCom (2001). Good agreement was observed between theoretical and experimental results for the effective atomic numbers of all the selected alloys.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

The Application of a Laser to the Chemical Characterization of Radionuclides

  • Park, Y.J.;Park, K.K.;M/Y. Suh;S.K. Yoon;Park, Y.S.;Kim, D.Y.;Kim, W.H.
    • Nuclear Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.446-456
    • /
    • 2000
  • Laser induced photoacoustic, fluorescence, and photon correlation spectroscopies were applied to the chemical characterization of radionuclides in connection with the radiowaste treatment and disposal. Their measuring principles and systems were briefly described together with their advantages over conventional spectroscopies. Also, other applications of lasers are introduced. Laser induced photoacoustic spectra were measured for a P $r^{3+}$ solution with a very low molar absorptivity. The detection sensitivity was 4.3 $\times$10$^{-5}$ c $m^{1}$ and was 100 times better than that of a UV/VIS spectrophotometer. The Eu(III) excitation spectra($^{7}$ $F_{0}$ longrightarrow $^{5}$ $D_{0}$ transition) were measured for Eu(III)-phthalate complexes using laser fluorescence spectroscopy, showing that only two species, 1:1 and 1:2 complexes, are present in the Eu(III)-phthalic acid system. The size and size distribution for colloidal humic acids and Eu(III)-humate colloids was determined using photon correlation spectroscopy. The presence of Eu(III) enhanced the aggregation of humic acids.s.

  • PDF

플라즈마발생기의 이온분율 측정 장치 설계 및 제작 (The design and fabricationt for ion fraction measurement of plasma generator)

  • 이찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

기상자료의 통계처리방법이 원자력발전소의 가상 사고시 단기 대기확산인자에 미치는 영향 (Influence of Statistical Compilation of Meteorological Data on Short-Term Atmospheric Dispersion Factors in a Hypothetical Accidental Release of Nuclear Power Plants)

  • 황원태;김은한;정해선;정효준;한문희
    • Journal of Radiation Protection and Research
    • /
    • 제37권3호
    • /
    • pp.116-122
    • /
    • 2012
  • 미국 원자력규제위원회(U. S. NRC)에서 개발한 PAVAN 프로그램을 사용하여 기상자료의 통계처리방법에 따른 원자력발전소의 수명기간 중 발생할 수 있는 가상 사고시 단기 대기확산인자 값의 영향을 분석하였다. 대기확산을 평가하기 위한 기본요소는 기상자료이며, PAVAN에서는 대기안정도에 대한 풍향과 풍속의 발생빈도를 나타내는 결합빈도분포자료를 사용하여 평가한다. 고리와 월성 원자력발전소 부지에서 2006~2010년까지 5년간 관측된 기상자료를 사용하여 풍속등급의 분류방법(U. S. NRC 권고와 균등발생빈도 분류방법)과 평가에 적용되는 기상자료의 통계처리기간(1년, 2년, 3년, 4년, 5년)에 따른 결합빈도분포자료를 작성하여 단기 대기확산인자를 평가하였다. 평가결과, 두 원자력발전소 부지 모두 풍속등급의 분류에 따른 단기 대기확산인자 값의 영향은 미미한 반면 평가에 적용되는 기상자료의 분석기간은 상대적으로 중요한 영향을 나타냈는데, 최대값과 최소값의 비는 1.5배 이상의 차이를 보였다.

Thermal-hydraulic safety analysis of radioisotope production in HANARO using MCNP6 and COMSOL multiphysics: A feasibility study

  • Taeyun Kim;Bo-Young Han;Seongwoo Yang;Jaegi Lee ;Gwang-Min Sun;Byung-Gun Park;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3996-4001
    • /
    • 2023
  • The High-flux Advanced Neutron Application Reactor (HANARO) produces radioisotopes (RIs) (131I, 192Ir, etc.) through neutron irradiation on various RI production targets. Among them, 177Lu and 166Ho are particularly promising owing to their theranostic characteristics that facilitate simultaneous diagnosis and treatment. Prior to neutron irradiation, evaluating the nuclear heating of the RI production target is essential for ensuring the thermal-hydraulic safety of HANARO. In this study, the feasibility of producing 177Lu and 166Ho using irradiation holes of HANARO was investigated in terms of thermal-hydraulic safety. The nuclear heating rates of the RI production target by prompt and delayed radiation were calculated using MCNP6. The calculated nuclear heating rates were used as an input parameter in COMSOL Multiphysics to obtain the temperature distribution in an irradiation hole. The degree of temperature increase of the 177Lu and 166Ho production targets satisfied the safety criteria of HANARO. The nuclear heating rates and temperature distribution obtained through the in silico study are expected to provide valuable insight into the production of 177Lu and 166Ho using HANARO.