• 제목/요약/키워드: atomic data

검색결과 1,410건 처리시간 0.022초

대기분진의 원소분석에 대한 k0-NAA법의 비교 (Comparative Analysis of Elemental Components in Airborne Particulate Matter by k0-NAA Methods)

  • 정용삼;문종화;조현제;김영진
    • 분석과학
    • /
    • 제18권1호
    • /
    • pp.51-58
    • /
    • 2005
  • A comparison of the analytical data obtained by three $k_0$-NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual $k_0$-NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established $k_0$-program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect.

탄소강의 유동가속부식에 미치는 크롬의 영향 (Effect of Cr on Flow Accelerated Corrosion of Carbon Steel)

  • 이은희;김경모;김홍표;김동진
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.25-32
    • /
    • 2015
  • The alloy content of structural materials of nuclear power plants has been recognized an important factor in predicting flow accelerated corrosion (FAC). In particular, many literature data reported that chromium content is one of the most important alloying element and even a small amount of chromium is effective to suppress FAC. This report reviewed and compared chromium models of Ducreux, Bouchacourt, and Kastner which were used in predicting FAC rates. The plant data indicate that Ducreux model may be conservative for the specimen containing 0.15 wt% chromium. The related articles were reviewed as follows. Combined effects of chromium content, pH, temperature, dissolved oxygen (DO), flow velocity, test time, and kinds of amine on the FAC rate were described. 0.1 wt% chromium in steel did not affect the FAC rate with changes in pH. The FAC rates pronounced with higher flow rate and increased with increasing test duration(600 d) for 0.013 wt% chromium. The FAC rates in mixed amine chemistry were higher than in ammonia chemistry, which may be lessened by the addition of chromium to the steel.

영광 3, 4호기 원자로 유동 모델 시험 (YGN 3 & 4 Reactor Flow Model Test)

  • Lee, Kye-Bock;Im, In-Young;Lee, Byung-Jin;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.340-351
    • /
    • 1991
  • l/5.03 축소 원자로 모델을 이용하여 원자력 발전소 영광 3,4호기를 위한 유동시험을 수행하였다. 이 유동 시험의 목적은 ABB-CE사의 System 80과 영광 3,4호기 원자로 크기의 상대적인 차이로 인해 발생하는 원자로 용기내의 수력학적 영향을 평가하는 것이다. 유동 모델은 상사성 원리에 따라 설계하였다. 이 시험에서 얻은 결과는 노심 입구 유량 분포, 노심 출구 압력 분포, 원자로 입구 노즐에서부터 출구 노즐까지 유동로를 따른 부분 구간 및 전체 압력 손실이다. 이 데이터들은 노심의 열적 여유도 분석에 필요한 입력 자료 제공과 해석적 수력설계 방법의 검증에 이용하게 된다.

  • PDF

Evaluation of the Demineralizer Performance and $^{65}Zn$ Activity on Spent Resin for a Zinc Addition Operation

  • Kim, Kwang-Rag;Sung, Ki-Woung;Na, Jung-Won;Kim, Uh-Chul
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.191-195
    • /
    • 2003
  • Zinc acetate has been proposed and used to evaluate ionic zinc as a means to reduce reactor radiation buildup at several nuclear plants. Thermodynamic analysis of the aqueous zinc system using reliable data shows that the stability of the hydrolyzed zinc species increases with pH and temperature. Adsorption kinetics and isotherm studies were carried out to investigate the mixed resin performance of the zinc adsorption. The equilibrium isotherms of the zinc adsorption onto nuclear grade resin indicate that the data correlate well with the Langmuir model and that the adsorption is physical in nature. The maximum capacity according to the Langrnuir model is about 0.6meq/g for an initial zinc concentration of 100ppm at $50^{\circ}C$. The use of natural zinc could result in the generation of a $^{65}Zn$ activity with about $500{\mu}Ci/mL$ of resin after 12 months of operation.

  • PDF

Elucidation of Electrode Reaction of EuCl3 in LiCl-KCl Eutectic Melts through CV Curve Analysis

  • Kim, Tack-Jin;Jung, Yong-Ju;Kim, Si-Hyung;Paek, Seung-Woo;Ahn, Do-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.863-866
    • /
    • 2011
  • The electrode reaction of $Eu^{3+}$ in a LiCl-KCl eutectic melt has been re-examined using cyclic voltammetry (CV). In this work, for the first time, the kinetic details of a $Eu^{3+}/Eu^{2+}$ redox system have been completely elucidated, along with the thermodynamic property, through a curve fitting applied to experimental CV data, which were obtained in a wide scan rate range of 0.5 to 10 V/s. The simulated results showed an excellent fit to all experimental CV data simultaneously, even though the curve fittings were performed within a large dynamic range of initial transfer coefficient values, formal potentials, and standard rate constants. As a result, a proper formal potential, transfer coefficient, and standard rate constant for the $Eu^{3+}/Eu^{2+}$ redox system were successfully extracted using the CV curve fitting.

KMRR 핵연료에 대한 고유량 임계열속 상관식 개발 (Development of a High Flow CHF Correlation for the KMRR Fuel)

  • Park, Cheol;Hwang, Dae-Hyun;Yoo, Yeon-Jong;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.237-246
    • /
    • 1994
  • KMRR 노심의 열수력 설계 및 안전 해석을 위한 고유량 CHF 상관식을 개발하였다. 상관식 개발에는 fin이 부착된 경우와 부착되지 않은 경우의 가열봉에 대한 단일봉 CHF 실험 자료를 사용하였다. 상관식은 Reynolds 수, 열역학 평형 건도, 액상과 기상의 밀도비 및 등가수력 직경비 등의 무차원 변수로 이루어져 있으며, fin이 있는 경우와 없는 경우의 가열 둘레비를 사용하여 fin의 영향을 고려하였다. 이처럼 단일봉에 대하여 개발된 상관식의 KMRR 핵연료 집합체에 대한 적용 타당성을 보이기 위하여 비가열면 및 축방향 비균일 출력 분포의 영향을 논의하였다. CHF 실험 자료 분석 결과, 상관식 한계 DNBR은 1.44로 결정되었다.

  • PDF

Design Study for Pulsed Proton Beam Generation

  • Kim, Han-Sung;Kwon, Hyeok-Jung;Seol, Kyung-Tae;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.189-199
    • /
    • 2016
  • Fast neutrons with a broad energy spectrum, with which it is possible to evaluate nuclear data for various research fields such as medical applications and the development of fusion reactors, can be generated by irradiating proton beams on target materials such as beryllium. To generate short-pulse proton beam, we adopted a deflector and slit system. In a simple deflector with slit system, most of the proton beam is blocked by the slit, especially when the beam pulse width is short. Therefore, the available beam current is very low, which results in low neutron flux. In this study, we proposed beam modulation using a buncher cavity to increase the available beam current. The ideal field pattern for the buncher cavity is sawtooth. To make the field pattern similar to a sawtooth waveform, a multiharmonic buncher was adopted. The design process for the multiharmonic buncher includes a beam dynamics calculation and three-dimensional electromagnetic simulation. In addition to the system design for pulsed proton generation, a test bench with a microwave ion source is under preparation to test the performance of the system. The design study results concerning the pulsed proton beam generation and the test bench preparation with some preliminary test results are presented in this paper.

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE

  • Lee, Jong-Il;Lee, Tae-Young;Kim, Bong-Whan;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.109-114
    • /
    • 2010
  • Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.

Design and development of enhanced criticality alarm system for nuclear applications

  • Srinivas Reddy, Padi;Kumar, R. Amudhu Ramesh;Mathews, M. Geo;Amarendra, G.
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.690-697
    • /
    • 2018
  • Criticality alarm systems (CASs) are mandatory in nuclear plants for prompt alarm in the event of any criticality incident. False criticality alarms are not desirable as they create a panic environment for radiation workers. The present article describes the design enhancement of the CAS at each stage and provides maximum availability, preventing false criticality alarms. The failure mode and effect analysis are carried out on each element of a CAS. Based on the analysis, additional hardware circuits are developed for early fault detection. Two different methods are developed, one method for channel loop functionality test and another method for dose alarm test using electronic transient pulse. The design enhancement made for the external systems that are integrated with a CAS includes the power supply, criticality evacuation hooter circuit, radiation data acquisition system along with selection of different soft alarm set points, and centralized electronic test facility. The CAS incorporating all improvements are assembled, installed, tested, and validated along with rigorous surveillance procedures in a nuclear plant for a period of 18,000 h.

Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulation

  • Berkay Camgoz;Dilara Tarim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2734-2741
    • /
    • 2023
  • Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics. The primary principle is to use as low as reasonably achievable dose in all ionizing radiation applications for diagnostic and therapeutic treatments. Dosimetric distributions are dependent on radioactive source properties and radiation-matter interactions in an absorber medium such as phantom or tissue. In this consideration, the geometrical structure and material of the seed capsule, which surrounds a radioactive material, are directly responsible for isodose profiles and dosimetric functions. In this study, the radiometric properties of capsule material were investigated on dose distribution in a water phantom by changing its nuclear properties using the EGSnrc Monte Carlo (MC) simulation code. Effective atomic numbers of hypothetic mixtures were calculated by using different elements with several fractions for capsule material. Model 6711 brachytherapy seed was modeled by EGSnrc/Dosrcnrc Code and dosimetric functions were calculated. As a result, dosimetric parameters of hypothetic sources have been acquired in large-scale atomic number. Dosimetric deviations between the data of hypothetic seeds and the original one were analyzed. Unit dose (Gy/Particle) distributions belonging to different types of material in seed capsule have remarkably differed from the original capsule's data. Capsule type is major variable to manage the expected dose profile and isodose distribution around a seed. This study shows us systematically varied scale of material type (cross section or effective atomic number dependent) offers selective material usage in production of seed capsules for the expected isodose profile of a specific source.