Browse > Article
http://dx.doi.org/10.5516/NET.2010.42.1.109

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE  

Lee, Jong-Il (Korea Atomic Energy Research Institute)
Lee, Tae-Young (Korea Atomic Energy Research Institute)
Kim, Bong-Whan (Korea Atomic Energy Research Institute)
Kim, Jang-Lyul (Korea Atomic Energy Research Institute)
Publication Information
Nuclear Engineering and Technology / v.42, no.1, 2010 , pp. 109-114 More about this Journal
Abstract
Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.
Keywords
BiDAS-2007 Computer Code; Internal Exposure; Simultaneous Analysis; Continual Intake Evaluation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 T. Y. Lee, J. K. Kim, J. I. Lee, and S. Y. Chang, "The BiDAS: Bioassay Data Analysis Software for Evaluating Radionuclide Intake and Dose," J. of the Korean Radioactive Waste Society, Vol. 2(2), pp.113-124 (2004).   과학기술학회마을
2 International Commission on Radiological Protection, "Individual Monitoring for Internal Exposure of Workers Replacement of ICRP Publication 54. ICRP Publication 78," Ann. ICRP 27(3/4), Oxford: Pergamon Press (1997).
3 H. Doerfel, A. Andrasi, and M. R. Bailey, "Third European intercomparison exercise on internal dose assessment," Research Center Karlsruhe, Research Report FZKA 6457, Karlsruhe. ISSN 0947-8620 (2000).
4 International Atomic Energy Agency, "Intercomparison Exercise on Internal Dose Assessment," IAEA-TECDOC- 1568 (2007).
5 V. Berkovski, G. Ratia, and Y. Bonchuk, "Individual Monitoring of the Internal Exposure Computer code Ver. INT04," Radiation Protection Institute, IMIE-2004 (2004).
6 A. Birchall, N. S. Jarvis, M. S. Peace, A. E. Riddell, and 114 W. P. Battersby, "The IMBA Suite: Integrated Modules for Bioassay Analysis," Radiat. Prot. Dosim. 79, 1-4, p.107- 110 (1998).   DOI