• 제목/요약/키워드: atmospheric samples

검색결과 609건 처리시간 0.025초

가속기 질량 분광분석법을 이용한 대기 환경 연구 (Accelerator Mass Spectrometry in Atmospheric Environment)

  • 문창범;채수조;정준오;정진도
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 1999
  • 가속기 질량분광분석법(Accelerator Mass Spectrometry; AMS)은 동위원소 분석에 있어 초정밀 질량 분석 기술에 속한다. 시료(Samples)의 원자를 이온화 시켜 가속시키고, 에너지, 운동량 그리고 전하 상태를 분석하여 최종 얻고자 하는 원자핵의 동위원소, 예를 들어 탄소-14$^{14)C$),의 수를 정확하게 측정하는 분광분석 기술이다. 본 논문을 통하여 AMS를 소개하고 대기 환경 연구에 AMS가 어떻게 응용될 수 있는지 살펴 보기로 한다.(중략)

  • PDF

서울시 대기오염물질이 마우스태자 간조직 세포의 소핵출현에 미치는 經胎盤 효과 (Tranceplacental Effect of Air Pollutants in Seoul to inducing Micronuclei from Polychromatic Erythrocytes in Mouse Fetal Liver)

  • 송동빈;김수한;김영환
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.111-117
    • /
    • 1990
  • To investigate the transplacental cytogenic effect of air pollutants the authors collected samples from Shinchon, Guro, Banpo and Jungnung-dongs in winter season. The air filters were extracted by mixture of benzene and ethanol, then a certain amount of extracted sustance was injected to pregnant mice at 16th day of gestation. From the fetal liver emulsion polychromatic erythrocytes were collected and stained with Giemsa solution. The cytogenic effect was evaluated by micronucleus test by which numbers of polychromatic erythrocytes containing microunclei (MNPCE) per 1, 000 polychromatic erythrocytes could be counted.

  • PDF

국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 - (Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구 (Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air)

  • 김기현;오상인;최여진;최규훈;주도원
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

Factors Controlling the Deposition of Airborne Metals on Plant Leaves in a Subtropical Industrial Environment

  • Gajbhiye, Triratnesh;Pandey, Sudhir Kumar;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권3호
    • /
    • pp.162-167
    • /
    • 2016
  • This study was conducted in an industrial city (Bilaspur) representative of subtropical area in central India. In order to assess the metal deposition on plant, concentrations of six target metals (i.e., Fe, Mn, Pb, Cu, Cd, and Cr) in both plant leaf and dust (deposited on its surface) samples were measured from six different sites. Metal concentrations in dust samples were found on the order of Fe>Mn> Cr>Pb>Cu>Cd. In contrast, the concentration of metals in plant leaves were seen on the order of Fe>Mn>Cr>Cd>Cu>Pb. As such, Cd showed significantly high concentration in leaves relative to their corresponding dust samples. A high accumulation potential for Fe and Cd was seen from Butea monosperma, while Mn and Pb were accumulated noticeably in Pongamia pinnata and Butea monosperma. Likewise, Cr and Cu were enriched in Calotropis procera, Alstonia scholaris, and Butea monosperma. The overall results of our study suggest that the foliar uptake pattern should vary considerably by an interactive role between plant and metal types.

석탄과 슬러지의 혼합연소에 따른 수은 배출 특성 (Mercury Emission Characteristics from Co-Combustion of Coal and Sludge)

  • 강신욱;심성훈;정상현;정종현;이상섭
    • 한국대기환경학회지
    • /
    • 제28권2호
    • /
    • pp.182-189
    • /
    • 2012
  • Co-combustion of sludge with coal is proposed as an alternative option for sludge disposal instead of ocean dumping. Because the combustion of sludge can cause emissions of various air pollutants, it is important to understand the characteristics of sludge combustion flue gases. Especially, very few studies are found to investigate mercury emissions from the co-combustion of sludge with coal. In this study, coal and sludge samples were prepared with different mixing ratios. These samples were combusted in a bench-scale combustor, and their flue gases were analyzed. Due to higher mercury content in the sludge sample, higher mercury emissions were found with an increase in a ratio of sludge to coal. Compared to the combustion flue gas of the coal sample, higher levels of mercury oxidation were found in the combustion flue gas of the samples including sludge.

실내공기 중 석면 섬유의 분류 및 확인을 위한 전문가 시스템의 개발 (Development of An Expert System for Classifying and Identifying Asbestos Fibers in the Indoor Air)

  • 김수환;김동술
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.703-712
    • /
    • 1999
  • In order to determine the number concentration of asbestos, it is initially necessary to develop a method to identify the type of asbestos. Thus a SEM/EDX was used to obtain both physical and chemical information from known asbestos samples as reference samples. Based on these information, we could make a source profile matrix consisted of a glass fiber and 3 other types of asbestos such as chrysotile, crocidolite, and tremolite. After collinearity test was performed for these sources, we could successfully develop an expert system by C-language to separate and to identify various unknown types of fiber particles. The expert system was perfectly self-verified with original reference data. Then the program was extensively applied to survey indoor and outdoor environment such as a residential area, an elementary school, and underground store, and an auto junkyard. As a result for surveying, a total of 442 individual fibrous particles were well classified into 4 types of particle classes above mentioned; 5.4% of chrysotile, 4.1% of crocidolite, 3.6% of glass fiber, and 86.9% of unknown fibers in terms of number concentration. However, tremolite was not detected in the study sites. All the samples were satisfied with the recommendation level of 0.01 f/cc.

  • PDF

완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석 (VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area)

  • 김득수;양고수;박비오
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.