• Title/Summary/Keyword: at speed test

Search Result 2,585, Processing Time 0.035 seconds

Network Performance Verification for Next-Generation Power Distribution Management System Using FRTU Simulator (FRTU 시뮬레이터를 이용한 차세대 배전지능화시스템 네트워크 성능검증)

  • Yeo, Sang-Uk;Son, Sung-Yong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.523-529
    • /
    • 2020
  • Power distribution management system is essential for the efficient management and operation of power distribution networks. The power distribution system is a system that manages the distribution network based on IT, and has been evolving along with the development of the power industry. The current power distribution system is designed to operate at a relatively low network transmission speed based on the independent operation of the main equipment. However, due to distributed resources such as photovoltaic or energy storage devices, which are rapidly increasing in popularity in recent years, the operation of future distribution environments is becoming more complex, and various information needs to be collected in real time. In this study, the requirements of the next-generation power distribution system were derived to overcome the limitations of the existing power distribution system, and based on this, the communication network system and performance requirements for the distribution system were defined. In order to verify the performance of the designed system, a software-based terminal device simulator was developed because it takes excessive time and cost to introduce a large-scale system such as a power distribution system. Using the simulator, a test environment similar to the actual operation was established, and the number of terminal devices was increased up to 1,000. The proposed system was shown to satisfy the requirements to support the functions of the next-generation power distribution system, recording less than 10 % of the communication network bandwidth.

Effects of Protein Intake on Sarcopenia Prevention and Physical Function of the Elderly in a Rural Community of South Korea During the COVID-19 Pandemic (COVID-19시대 한국 농촌 지역 노인의 단백질 섭취가 근감소증 예방 및 신체기능에 미치는 영향)

  • Li, Xinxing;Kim, Hee-Jae;Kim, Dae-Young;Zhang, Yanjie;Seo, Ji-Won;Ahn, Seo-Hyun;Song, Wook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.2
    • /
    • pp.37-47
    • /
    • 2022
  • Purpose : We aimed to investigate the effects of nutritional foods on sarcopenia prevention and physical function among the elderly living in rural communities during the COVID-19 pandemic by providing customized nutrition. Methods : This study was conducted in the rural community of SCC. Participants (n=24, over age 65) were randomly assigned into a Protein group (n=12) and a Vitamin group (n=12). The protein group was given 23 g/d of protein (whey, soybean, BCAA) for 8 weeks and the Vitamin group 23 g/d of vitamin (B, C, D, E and mixed minerals such as calcium, magnesium, zinc) for 8 weeks. All participants had their body composition such as height, weight, skeletal muscle mass, body mass index, and body fat percentage, measured using bioelectrical impedance analysis (BIA) and physical function assessed using grip strength and the short physical performance battery (SPPB). Results : At the end of the intervention, there was a significant increase in skeletal muscle mass (p<.01) in the Protein group (p=.002, 4.92 %) compared to the baseline: it increased by 2.33 %. The Vitamin group had a significant increase in body fat percentage after the intervention (p=.001, 15.35 %) compared to the baseline: body fat percentage decreased by 4.49 %. There were no significant differences in left and right Grip strength/Weight, SPPB, 4-m gait speed, chair stand test, and sense of balance in both groups. Conclusion : The findings from this study suggest that 8 weeks of protein intake have a significant effect on skeletal muscle mass and body fat percentage. Protein intake helped promoting the health of the elderly in rural community during the COVID-19 pandemic. It will assist creating a foundation for providing customized nutrition for the elderly in rural community in the future.

Fire Resistance Assessment of Precast Duct Slab with Fireproof using Hardening Accelerator (경화촉진제를 사용한 내화재 일체형 프리캐스트 슬래브의 화재저항성능 평가)

  • Soon-Wook, Choi;Tae-Ho, Kang;Chulho, Lee;Se Kwon, Kim;Tae Kyun, Kim;Soo-Ho, Chang
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.363-372
    • /
    • 2022
  • Precast concrete is an effective method to increase the construction quality and construction speed by optimizing and making the manufacturing conditions similar. In order to more effectively produce a fireproof material-integrated precast duct slab, the purpose of this study was to determine whether the fire resistance performance of the fireproof layer is maintained when a method of increasing the curing rate using a hardening accelerator is used. As a result of performing a fire resistance performance test on specimens classified according to whether or not the hardening accelerator was included, increase of temperature inside the specimen was high in the specimens using the hardening accelerator, and the section loss of the fireproof layer occurred locally on the surface exposed to fire heating. In conclusion, it is judged that the fireproof layer in the case where the strength at 3th day of age is gained within 1 day curing age using a hardening accelerator does not guarantee sufficient fire resistance performance in the conditions used in this study.

Design and Implementation of a Data-Driven Defect and Linearity Assessment Monitoring System for Electric Power Steering (전동식 파워 스티어링을 위한 데이터 기반 결함 및 선형성 평가 모니터링 시스템의 설계 구현)

  • Lawal Alabe Wale;Kimleang Kea;Youngsun Han;Tea-Kyung Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.2
    • /
    • pp.61-69
    • /
    • 2023
  • In recent years, due to heightened environmental awareness, Electric Power Steering (EPS) has been increasingly adopted as the steering control unit in manufactured vehicles. This has had numerous benefits, such as improved steering power, elimination of hydraulic hose leaks and reduced fuel consumption. However, for EPS systems to respond to actions, sensors must be employed; this means that the consistency of the sensor's linear variation is integral to the stability of the steering response. To ensure quality control, a reliable method for detecting defects and assessing linearity is required to assess the sensitivity of the EPS sensor to changes in the internal design characters. This paper proposes a data-driven defect and linearity assessment monitoring system, which can be used to analyze EPS component defects and linearity based on vehicle speed interval division. The approach is validated experimentally using data collected from an EPS test jig and is further enhanced by the inclusion of a Graphical User Interface (GUI). Based on the design, the developed system effectively performs defect detection with an accuracy of 0.99 percent and obtains a linearity assessment score at varying vehicle speeds.

The Efficacy of Low Frequency Electroacupuncture Therapy for Weight Loss in Obese Korean Women (저주파 전침 위주의 한방비만치료의 체중감량 효과 및 관련 인자에 관한 연구)

  • Hwang, Deok-Sang;Lee, Yoon-Jae;Lee, Chang-Hoon;Kim, Yong-Suk;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.2
    • /
    • pp.140-150
    • /
    • 2009
  • Purpose: We investigated the efficacy of electroacupuncture therapy in obese Korean women in order to make basic guidelines for the use of oriental medicine in treating obesity. Methods: Forty women were divided into two groups and each was treated 12 times: 1) one group was treated using electroacupuncture (EA) involving auricular acupuncture and physical treatment, without exercise (EA group, n=10), and 2) the other group was treated using electroacupuncture and exercise (EA plus exercise group, n=30). The EA was applied to subcutaneous fat tissue manually. Body weight was evaluated every visit and body composition was checked at the $1^{st}$ and $12^{th}$ visits. Statistical comparisons were made using SPSS13.0. We compared the weight loss, body mass index (BMI), and body composition before and after treatment using the pairedt-test. The correlations between weight loss and BMI and age were examined. Results: After the $12^{th}$ treatment, both groups showed significant reductions in body weight, BMI, body fat, and body fat percentage. The weight loss averaged 4.58${\pm}$3.87% in the EA group and 4.69${\pm}$3.10% in the EA plus Exercise group. The reduction in skeletal muscle was significant in the EA group, but not significant in the EA plus Exercise group. The speed of the weight loss was correlated with age using Pearson's correlation coefficient. Based on BMI, normal and obese subjects in the EA plus Exercise group had significant reductions in body weight, BMI, body fat, and body fat percentage; the obese subjects also had a significant reduction in skeletal muscle. Conclusion: Combined EA therapy may be effective for weight reduction. Age and BMI were related to weight loss using EA therapy.

A Study on the Establishment of Entropy Source Model Using Quantum Characteristic-Based Chips (양자 특성 기반 칩을 활용한 엔트로피 소스 모델 수립 방법에 관한 연구)

  • Kim, Dae-Hyung;Kim, Jubin;Ji, Dong-Hwa
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.140-142
    • /
    • 2021
  • Mobile communication technology after 5th generation requires high speed, hyper-connection, and low latency communication. In order to meet technical requirements for secure hyper-connectivity, low-spec IoT devices that are considered the end of IoT services must also be able to provide the same level of security as high-spec servers. For the purpose of performing these security functions, it is required for cryptographic keys to have the necessary degree of stability in cryptographic algorithms. Cryptographic keys are usually generated from cryptographic random number generators. At this time, good noise sources are needed to generate random numbers, and hardware random number generators such as TRNG are used because it is difficult for the low-spec device environment to obtain sufficient noise sources. In this paper we used the chip which is based on quantum characteristics where the decay of radioactive isotopes is unpredictable, and we presented a variety of methods (TRNG) obtaining an entropy source in the form of binary-bit series. In addition, we conducted the NIST SP 800-90B test for the entropy of output values generated by each TRNG to compare the amount of entropy with each method.

  • PDF

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

The effect of using laser for ceramic bracket bonding of porcelain surfaces (세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과)

  • An, Kyung-Mi;Sohn, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the effect of using laser for ceramic bracket bonding of porcelain surfaces and to compare it with conventional treatment of porcelain surfaces. Methods: Ninety feldspathic porcelain specimens were divided into 9 groups of 10, with each group having different surface treatments performed. Surface treatment groups were orthophosphoric acid, orthophosphoric acid with silane, hydrofluoric acid, hydrofluoric acid with silane, sandblasted, sandblasted with silane, laser etched, laser etched with silane, and glazed surface served as a control group. In the laser etched groups, the specimens were irradiated with 2-watt superpulse carbon dioxide ($CO_2$) laser for 20 seconds. Ceramic brackets were bonded with light-cure composite resin and all specimens were stored in water at $37^{\circ}C$ for 24 hours. Shear bond strength was determined in megapascals (MPa) by shear test at 1 mm/minute crosshead speed and the failure pattern was assessed. For statistical analysis, one-way ANOVA and tukey test were used. Results: Statistical analysis showed significant differences between the groups. The HFA + S group showed the highest mean shear bond strength ($13.92{\pm}1.94\;MPa$). This was followed by SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA ($10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), G ($2.46\;{\pm}\;1.36\;MPa$), Bond failure patterns of HFA and silane groups, except L + S, were cohesive modes in porcelain while adhesive failure was observed in the control group and the rest of the groups. Conclusions : A 2-watt superpulse $CO_2$ laser etching of porcelain surfaces can provide a satisfactory result for porcelain surface treatment for ceramic bracket bonding. Laser irradiation may be an alternative conditioning method for the treatment of porcelain surfaces.