• 제목/요약/키워드: asymmetrical

검색결과 722건 처리시간 0.026초

유한요소해석을 이용한 비대칭 평면형 결합선로 설계 (Design of Asymmetrical Parallel Coupled lines Using Finite Element Analysis)

  • 윤재호;박준석;안달;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1841-1843
    • /
    • 2001
  • Asymmetrical parallel coupled lines are used in a number of circuits such as multi-band coupler and combline type band pass filter. Although graphical results and formulas are available for the design of coupled lines, the design procedure is hard to use, because even- and odd- mode impedances are always expressed in terms of the physical geometry. In this paper, we introduce a method to find design parameter using finite element analysis. By employing the capacitance obtained by FE analysis, design parameters for each lines are extracted. To show the validity of extracted design parameter for asymmetrical parallel coupled line, we have designed and simulated a planar type combline band pass filter.

  • PDF

절반 흉골반전법;비대칭 누두흉에 대한 새로운 수술기법의 제안 (One-half Sternal Turnover; New Operative Approach for Asymmetrical Funnel Chest)

  • 이승열
    • Journal of Chest Surgery
    • /
    • 제26권12호
    • /
    • pp.969-971
    • /
    • 1993
  • The sternal turnover has a limited use in an asymmetrical funnel chest. However we tried `One-half sternal turnover` as a new operative approach for an asymmetrical funnel chest. Through the bilateral submammary skin incision, median sternotomy was made from xiphoid process to midsternum and extended horizontally. The segment of ribs were cut at the angle of depression. The en-bloc resected chest wall segment contained one-half sternum as well as a part of ribs and left half of rectus muscle. After turning over the en-bloc segment, reapproximation with wiring was done. Sternotomy wound was closed in layer after placing of substernal drainage tube. Postoperatively, the chest wall was stable and the recovery course was uneventful except left-sided minimal pneumothorax which was cured spontaneaously. The patient was discharged on postoperative 14th day.

  • PDF

비대칭 하프 브릿지 직류-직류 컨버터에 적용된 전류 제어의 성능평가 비교 (Comparative Performance Evaluation of Current-Mode Controls Adapted to Asymmetrical Half-Bridge Dc-to-Dc Converters)

  • 임원석;최병조;박성우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.257-260
    • /
    • 2005
  • Three different current-mode control schemes, peak current-mode control, charge control, and average current-mode control, are investigated for applications to asymmetrical half-bridge dc-to-dc converters. The principles, implementation, and performance of the three control schemes are compared in an attempt to identify the irrespective merits and limitations. Design examples for feedback compensations are given for the three control schemes. A 50 W experimental asymmetrical half-bridge dc-to-dc converter was used to experimentally verify the theoretical results of the paper.

  • PDF

비대칭 결합선로 등가회로를 사용한 Comb-line 구조의 대역통과 여파기 설계 (A Study on The Design of Planer Comb-Line Bandpass Filter Using Equivalent Circuits of Asymmetrical Coupled Line)

  • 윤재호;박준석;김형석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.368-374
    • /
    • 2002
  • In this paper, we introduce a procedure to obtain a equivalent circuit of comb-line band pass filter. By employing equivalent circuits of each asymmetrical coupled line. we composed the full equivalent circuit of comb-line bandpass filter and derived simple design equations for extracting each line's impedance. To show the validity of design equations, we simulated and fabricated a planar type comb-line bandpass filter, which has center frequency 1.8㎓, band-width 50㎒ and four resonators. The resulting filter is very compact, have broad stop band with the second pass band centered at four times the center frequency of the first pass band. The experimental results show exact performances of design specification.

Fuzzy Controlled ZVS Asymmetrical PWM Full-bridge DC-DC Converter for Constant load High Power Applications

  • Marikkannan., A;Manikandan., B.V
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1235-1244
    • /
    • 2017
  • This paper proposes a fuzzy logic controlled new topology of high voltage gain zero voltage switching (ZVS) asymmetrical PWM full-bridge DC-DC boost converter for constant load and high power applications. The APWM full-bridge stage provides high voltage gain and soft-switching characteristics increase the efficiency and reduce the switching losses. Fuzzy logic controller (FLC) improves the performance and dynamic characteristics of the proposed converter. A comparison with a classical proportional-integral (PI) controller demonstrates the high performances of the proposed technique in terms of effective output voltage regulation under different operating conditions. Simulation is done by integrating two different simulation platforms $PSIM^{(R)}$ and $Matlab^{(R)}/Simulink^{(R)}$ by using SimCoupler tool of $PSIM^{(R)}$. Experimental results using 120W load have been provided to validate the results.

Asymmetrical PWM for Harmonics Reduction and Power Factor Improvement in PWM AC Choppers Using Bee Colony Optimization

  • Sanjit, Panithi;Aurasopon, Apinan
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.227-234
    • /
    • 2015
  • This paper presents the application of bee colony optimization (BCO) to obtain the optimal switching angles for single phase PWM AC choppers. The optimal switching angles are found in the region of 0-${\pi}$ based on the asymmetrical PWM technique. This PWM process results in improvements of the total harmonic distortion of the output voltage and in the input power factor. Simulation and experimental results are compared with the conventional PWM to verify the performance of the proposed PWM process.

Congenital unilateral hypoplasia of depressor anguli oris muscle in adult

  • Oh, Suk Joon
    • 대한두개안면성형외과학회지
    • /
    • 제20권4호
    • /
    • pp.265-269
    • /
    • 2019
  • Congenital hypoplasia of the depressor anguli oris muscle is a rare cause of asymmetrical crying facies in newborns. The clinical manifestations range from mild to severe asymmetry and may persist up to adulthood. In the current case, the patient did not exhibit other congenital anomalies or paralysis of other branches of the facial nerve. This adult patient presented with severe asymmetrical lower lip deformity during full mouth opening since birth. A chromosomal study for the detection of 22q gene deletion yielded negative results. The electromyography findings of the lower lip were insignificant. Depressor labii inferioris muscle resection was not effective, but bidirectional (horizontal and vertical) fascia lata grafting improved the aesthetic appearance of the asymmetrical lower lip. The patient showed improved lower lip symmetry during full mouth opening at 1 year after the surgery. Therefore, the details of this rare case are reported herein.

2축 시스템의 비대칭 윤곽제어 (Asymmetrical Contouring Control of Biaxial System)

  • 심영복;정유철;이건복
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.65-72
    • /
    • 1997
  • An asymmetrical cross-coupled compensator to improve the contouring performance is proposed. This is a refinement of the structure suggested by Koren. The position loop is closed with a proportional controller as in the uncoupled system. An additional input term proportional to the component of the contour error along the corresponding axis is included. The controller gains are chosen to give an appropriate frequency response and an optimum range for the damping ratio. The effectiveness of the proposed controller is studied by means of digital simulations of the dynamics of the drives and the controller for 4 types of command trajectories: straight line contour, cornering contour, circular contour, elliptic contour. Substantial improvement in contouring performance is obtained for a range of contouring conditions.

  • PDF

난청인의 난청 정도에 따른 비대칭 청각 필터 구현의 객관적 평가 (An Objective Estimation for Simulating of Asymmetrical Auditory Filter of the Hearing Impaired According to Hearing Loss Degree)

  • 주상익;전유용;송영록;이상민
    • 재활복지공학회논문지
    • /
    • 제3권1호
    • /
    • pp.27-34
    • /
    • 2009
  • 난청인의 청력 손실은 개인별로 다양하므로 기존의 대칭적으로 주파수 밴드별 청각 필터를 구현하는 방법은 다양한 형태의 난청인의 청력 손실을 적절하게 모사해주지 못한다. 각 중심주파수와 음성의 입력크기에 따라 청각 필터의 형태가 비대칭적으로 바뀌고 청력손실이 있는 난청인은 청력 손실에 따라 청각필터의 형태가 정상인들과는 다른 형태로 바뀌게 되며 음질에도 차이가 있다. 본 연구에서는 난청인의 난청 정도에 따라 변하는 비대칭 청각 특성을 잘 반영한 청각필터를 구현하여 몇 가지 실험을 통해 각 구현된 청각 필터의 성능을 객관적으로 평가하였다. 실험은 구현된 청각 필터를 통한 음성의 perceptual evaluation of speech quality (PESQ) 와 log likelihood ratio (LLR)를 사용하였으며 그 값을 통해 처리된 음성의 객관적인 음질과 왜곡정도를 평가 하였다. 청력 손실을 주었을 때 대칭과 비대칭 청각 필터사이의 PESQ 와 LLR 값을 실험해 본 결과 청각 필터 간의 큰 차이를 보였다. 위 실험 결과들로 대칭과 비대칭 청각 필터의 형태에 따라서 음성의 음질에 영향을 받는다는 것을 알 수 있었다. 특히, 난청이 있을 때 중심 주파수별 청각 필터의 비대칭적 형태 변화가 난청인이 받아들이는 음질에 영향이 있었다.

  • PDF

비대칭 소프트 스위칭 하프 브리지 컨버터의 공진 특성 분석 (Analysis of Resonant Characteristics in Asymmetrical Soft Switching Half Bridge Converter)

  • 연재율;안중록;장도현;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1100-1102
    • /
    • 2002
  • In this paper, resonant characteri-sties of the asymmetrical soft switching half bridge converter is analyzed. The operation principle for proposed converter is explained in steady-state and its operation characteristics by switching frequency is presented with experimental result. Experimental results carried out on a system prototype are included in this paper.

  • PDF