• 제목/요약/키워드: asymmetric nose

검색결과 13건 처리시간 0.021초

편측 구순구개열 환자에서 ANS 골절단술을 이용한 코 비대칭의 교정 (ANS Repositioning for Correction of Asymmetric Nose in Unilateral Cleft Lip and Palate)

  • 정영수;김기호;이상휘;이충국
    • 대한구순구개열학회지
    • /
    • 제8권2호
    • /
    • pp.87-94
    • /
    • 2005
  • Patients with unilateral cleft lip and palate (UCLP) generally demonstrate the asymmetries in the lip, nose and the naso-maxillary complex. And their skeletal asymmetries are known to be derived from the displacement of nasal septum, anterior nasal spine (ANS) and the pre-maxilla toward the non-affected side during the developmental and growth period. Due to the interruption of the important facial muscles, which are critical for the symmetric growth of premaxilla, functional matrix system fails to develop and results in the displacement of the ANS toward the non-affected side and nasal asymmetry. Therefore the rhinoplasty for CLP patients is required to have inter-skeletal and muscular rearrangement in the naso-maxillary complex in order to let them recover from esthetic and physiologic imbalances. And functional cheilorhinoplasty (FCR) has been a representative treatment of choice for this concept of treatment modality. The outcome and prognosis of primary or repair FCR have been known to be definitely affected by timing of the operation as well as adequate reconstruction of naso-labial muscles. However, sometimes FCR has an ineffective treatment results for patients after the facial growth period, and the limited rhinoplasty around the nose often fails to bring satisfying results. In order to circumvent this limitation, we performed ANS osteotomy for patients with unilateral CLP showing asymmetric nose, as an alternative way for corrective rhinoplasty. We could observe that the nose was rearranged along the facial mid-line by this osteotomy design and asymmetries were evidently improved postoperatively. Here we present this osteotomy method in CLP patients.

  • PDF

3D camera를 이용한 일측성 구순비변형환자에서의 비하부 및 상구순 비대칭의 정량적 분석 (Quantitative Analysis of Lower Nose and Upper Lip Asymmetry in Patient with Unilateral Cleft Lip Nose Deformity using 3D camera)

  • 오태석;고경석;김태곤
    • Archives of Plastic Surgery
    • /
    • 제36권6호
    • /
    • pp.702-706
    • /
    • 2009
  • Purpose: Analysis of lower nose and upper lip asymmetry in patients with unilateral cleft lip nose deformity has been proceeded through direct measurement and photo analysis. But there are limitation in presenting real image because of its 2 dimensional trait. The authors analyzed such an asymmetry using 3D VECTRA system (Canfield, NJ, USA) in quantitative way. Methods: In 25 Patients with unilateral cleft lip nose deformity(male 12, female 13, age ranging from 4 to 19), patients with right side deformity were 10 and left were 15. Analysis of asymmetry was proceeded through 3D VECTRA system. After taking 3 dimensional photo, alar area, upper lip area, nostril perimeter, nostril area, Cupid's bow length, nostril height and nostril width were measured. Correlation coefficient and inter data quotients were calculated. Results: In nostril perimeter, maximal difference of cleft side and non - cleft side was 39.3%, asymmetric quotient Qasy = Qcl/Qncl(Qcl, value of cleft side; Qncl, value of non - cleft side) was ranged from 0.84 to 1.85 and in seven cases the length of cleft side was smaller. In nostril area, maximal difference was 69.6% and in 13 cases cleft side was smaller. In lower nasal area, maximal difference was 37.2% asymmetric quotient Qasy = Qcl/Qncl was ranged from 0.47 to 2.03 and in 20 cases cleft side was smaller. The correlation coefficients of nostril perimeter and area were 0.8345. Conclusion: Using 3D VECTRA system, the authors can measure nostril perimeter and lower nasal area that could not been measured with previous methods. Asymmetry of midface was analyzed through area comparison in quantitative way. Futhermore, post operative change can be measured in quantitative method.

아음속 유동하의 고 받음각 물체 주위의 비대칭 와류 특성 연구 (Asymmetric Vortices around a Body at High Angle of Attack Subsonic Flow)

  • 박미영;김완섭;이재우;박수형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.33-38
    • /
    • 2008
  • Numerical investigation of asymmetric vortices at high angles of attack subsonic flow is performed using three-dimensional Navier-Stokes equations. A small bump has been carefully selected and attached near the nose of an ogive cylinder to simulate symmetric vortices. Selected bump shape does develop asymmetric vortices and is verified using Lamont's experimental results. By changing the angle of attack, Reynolds numbers, and Mach numbers, the characteristics of asymmetric vortices are observed. The angle of attack which contributes significantly to the generation of asymmetric vortices are over 30 degrees. By increasing Mach number and Reynolds number asymmetric vortices, hence the side forces show decreasing trend..

  • PDF

고받음각 초음속 유동에서의 세장형 몸체 주변에 발생하는 비대칭와류에 대한 수치적 연구 (The Numerical Analysis of Asymmetric Vortices around the Slender body at High Angle of Attack Supersonic Flow)

  • 전영진;지영무;김기수;서형석;변영환;이재우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.335-338
    • /
    • 2007
  • 공대공미사일의 경우 초음속 하에서 고 기동성을 얻기 위하여 고받음각 능력이 요구되어진다. 옆 미끄러짐이 없는 대칭형 세장형 몸체의 경우라도 비대칭 와류는 생성된다. 이러한 비대칭 와류는 불필요한 측력 및 요잉모멘트를 발생시키고 이는 곧 방향 안전성을 저하시킨다. 본 연구는 전산해석을 통하여 초음속유동하에서 세장형 몸체 주변에 발생되는 비대칭와류 모사를 실시하였으며 비대칭 와류의 모사를 위해 선두부에 Bump를 장착하였다. 전산해석 결과 세장형 몸체 주변에 발생하는 비대칭와류를 모사 할 수 있었다.

  • PDF

고받음각 오자이브의 비대칭 와류에 작용하는 구동기 효과 분석 (Effect of the Flow Actuator on the Asymmetric Vortex at High Angle of Attack)

  • 이은석;이진익;이광섭
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.607-612
    • /
    • 2013
  • The effect of the flow actuator on the asymmetric vortex structure around the ogive-cylinder body with fineness ratio of 4 flying at the speed of Mach 0.1 at angle of attack of 50 degree is studied. The ogive-cylinder model is developed with the actuator placed near the nose tip and numerically simulated using the in-house CFD code named KFLOW. The numerical simulation employs two different actuator modeling: one is the boundary condition given by blowing normal to the surface and another shearing on the surface. The numerical simulation reveals that response of the vortex structure to the actuation is dependent on the type of modeling as well as the strength and direction of the actuation.

세장형 물체 주위 고앙각 유동의 비대칭 와류 및 측력 특성에 관한 수치적 연구 (A NUMERICAL STUDY ON THE CHARACTERISTICS OF ASYMMETRIC VORTICES AND SIDE FORCES ON SLENDER BODIES AT HIGH ANGLES OF ATTACK)

  • 정성기;정재홍;명노신;조태환
    • 한국전산유체공학회지
    • /
    • 제11권3호
    • /
    • pp.22-27
    • /
    • 2006
  • Flow around a guided missile in high maneuver, i.e. at a high angle of attack, shows complex phenomena. It is well known that even in geometrically symmetric conditions the flow around a missile at high angles of attack can generate unexpected large side forces and yaw moments due to asymmetric vortices. In this paper, a CFD code (FLUENT) based on the Navier-Stokes equations was used for the numerical analysis to find a suitable numerical mechanism for generation of asymmetric vortices. It is shown that a numerical technique of applying different surface roughness to a specific area of the missile nose surface gives the best fit in comparison with the experimental results. In addition, a numerical investigation of variations of side forces and pressure distributions with angle of attack and roll angle was conducted for the purpose of identifying the source of vortex asymmetries.

고받음각 동체에 발생하는 측력의 실험적 재현 및 수치적 분석 (EXPERIMENTAL REPRODUCTION AND NUMERICAL ANALYSIS OF THE SIDE FORCE ON AN OGIVE FOREBODY AT A HIGH ANGLE OF ATTACK)

  • 이은석;이진익;이광섭
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.28-35
    • /
    • 2013
  • Behavior of the side force generated at high angles of attack by two ogive-cylinder bodies of revolution with nose fineness ratio of 2.3 (B1) and 3.5 (B2) and the effect of a strip placed close the nose tip of each body (B1S and B2S) are analyzed through the wind tunnel test at ReD=200,000 and a=42~60 deg. The side force generated by B1 is increased by placing a strip. The side force generated by B2 is in the starboard direction and its magnitude is higher than that of the B1S. The effect of the strips with various dimensions placed on B2 is investigated. It is found that the 4-layer strip placed on the starboard reversed the direction of the side force into port direction. It is confirmed by numerical simulations that the strip promotes the flow separation and increases the average pressure on the side where it is placed and consequently produces the side force in the corresponding direction.

제동시 발생하는 리어 드럼브레이크 Grunt(stick-slip) Noise 개선 (Rear Drum Brake Grunt(stick-slip) Noise Improvement on Braking During Nose-dive & Return Condition)

  • 홍일민;장명훈;김선호;최홍석
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.781-788
    • /
    • 2013
  • Grunt(stick-slip) noise happens between rear lining and drum on braking condition while vehicle is returning to steady position after nose-dive. The study presents a new testing and analysis methods for improving brake grunt noise on vehicle. Grunt noise is called a kind of stick slip noise with below 1 kHz frequency that is caused by the surfaces alternating between sticking to each other and sliding over each other with a corresponding change in friction force. This noise is typically come from that the static friction coefficient of surfaces is much higher than the kinetic friction coefficient. For the identification of the excitation mechanism and improvement of grunt noise, it is necessary to study variable parameters of rear drum brake systems on vehicle and to implement CAE analysis with stick slip model of drum brake. The aim of this study has been to find solution parameters throughout test result on vehicle and dynamo test. As a result of this study, it is generated from stick slip between rear lining and rear drum and it can be solved to reduce contact angle of lining with asymmetric and is effected not only brake drum strength but also rear brake size and brake factor.

제동시 발생하는 리어 드럼브레이크 grunt (stick-slip) noise 개선 (Rear drum brake grunt (stick-slip) noise improvement on braking during nose-dive & return condition)

  • 홍일민;장명훈;김선호;최홍석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.743-749
    • /
    • 2012
  • Grunt (Stick-slip) noise happens between rear lining and drum on braking condition while vehicle is returning to steady position after nose-dive. The study presents a new testing and analysis methods for improving brake grunt noise on vehicle. Grunt noise is called a kind of stick slip noise with below 1kHz frequency that is caused by the surfaces alternating between sticking to each other and sliding over each other with a corresponding change in friction force. This noise is typically come from that the static friction coefficient of surfaces is much higher than the kinetic friction coefficient. For the identification of the excitation mechanism and improvement of grunt noise, it is necessary to study variable parameters of rear drum brake systems on vehicle and to implement CAE analysis with stick slip model of drum brake. The aim of this study has been to find solution parameters throughout test result on vehicle and dynamo test. As a result of this study, it is generated from stick slip between rear lining and rear drum and it can be solved to reduce contact angle of lining with asymmetric and is effected not only brake drum strength but also rear brake size and brake factor.

  • PDF

안모비대칭의 진단용 기준선의 유용성에 관한 연구 (A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY)

  • 류성호;장현호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.