• Title/Summary/Keyword: assessment scale

Search Result 3,149, Processing Time 0.031 seconds

Development and Application of Self-Evaluation Test Items for Secondary Science Teacher Professional Growth (중등 과학교사의 전문성 향상을 위한 자기평가 도구의 개발과 적용)

  • Kim, Sung-won;Jeong, Se-Mi;Hwang, Yoon-Jin
    • Journal of The Korean Association For Science Education
    • /
    • v.25 no.7
    • /
    • pp.736-745
    • /
    • 2005
  • The purpose of this paper was to develop and execute self-appraisal test items on secondary science teachers. Test items included 6 sub-fields-subject knowledge, teaching strategies, teaching skills, assessment, laboratory management, and professional development - and 77 items. Using these test items, science teachers were able to evaluate their ability as prescribed by a 5-point Likert scale. Furthermore, teachers were able to comprehend fields showing their highest and lowest scores among the 6 sub-fields. They could then place special attention on the lowest field insuring self-growth as a science teacher. Self-appraisal test items were developed by analyzing related references on teacher evaluation criteria and standards. 220 subjects composed the sample on which these test items were executed. The results of this study were as follows. First, content validity of the test items was 80.8%. The range of sub-field reliabilities was .76 - .86 and the reliability coefficient of the entire test was .95. The range of correlation coefficient between each subfield was .54 - .69 and that of subfields and entire test was .54 - .79. The correlation coefficient between professional development and the whole test was .79, the highest coefficient observed. Second, significant difference was found according to teaching experience. More experienced teachers had higher scores in all 6 sub-fields (p<.05). In addition, a significant difference according to gender was observed in subject knowledge and laboratory management (p<.05); male teachers had higher scores than female teachers. Also, the higher the level of experience, the higher the scores for subject knowledge (p<.05). Lastly, the teacher's major did not result in any significant differences.

Development of a Measuring Tool for Spiritual Care Performance of Hospice Team Members (호스피스 팀원들의 영적 돌봄 수행도 측정 도구 개발)

  • Yoo, Yang-Sook;Han, Sung-Suk;Lee, Sun-Mi;Seo, Min-Jeong;Hong, Jin-Ui
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.2
    • /
    • pp.86-92
    • /
    • 2006
  • Purpose: This study was conducted to develop a measuring tool for spiritual care performance of hospice team members. The tool may be utilized for providing hospice patients with more systematic and standardized spiritual tares. Methods: The concept and questions of the tool were developed, and then its validity and reliability were tested. For the validity and reliability tests, a self-reported questionnaire comprising 33 questions with 4 point scale ($1{\sim}4$), was developed, and the data were collected from 192 hospice team members from December 2005 to February 2006. Results: Thirty three questions, drafted through literature review and professional consultation, were reviewed by 20 professionals for their validity, were revised and supplemented resulted in the final 33 questions. The questions with a correlation coefficient grater than .30 were selected: all the 33 questions were selected based on this criterion. The reliability coefficient, Cronbarh's ${\alpha}$, was 0.95. The 33 questions were analyzed for factors, and six factors were extracted: relationship formation and communication, encouragement and promotion of spiritual growth, linking with spiritual resources, preparation of death, evaluation and quality control for spiritual intervention, Intervention, and spiritual assessment for intervention. Conclusion: The tool developed in this study includes six factors and has high level of reliability. This tool Will greatly contribute to assess and improve hospice care services, providing systematic and standardized spiritual cares for terminally ill patients and their families.

  • PDF

Factors Associated with Care Burden among Family Caregivers of Terminally Ill Cancer Patients (말기암환자 가족 간병인의 간병 부담과 관련된 요인)

  • Lee, Jee Hye;Park, Hyun Kyung;Hwang, In Cheol;Kim, Hyo Min;Koh, Su-Jin;Kim, Young Sung;Lee, Yong Joo;Choi, Youn Seon;Hwang, Sun Wook;Ahn, Hong Yup
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.1
    • /
    • pp.61-69
    • /
    • 2016
  • Purpose: It is important to alleviate care burden for terminal cancer patients and their families. This study investigated the factors associated with care burden among family caregivers (FCs) of terminally ill cancer patients. Methods: We analyzed data from 289 FCs of terminal cancer patients who were admitted to palliative care units of seven medical centers in Korea. Care burden was assessed using the Korean version of Caregiver Reaction Assessment (CRA) scale which comprises five domains. A multivariate logistic regression model with stepwise variable selection was used to identify factors associated with care burden. Results: Diverse associating factors were identified in each CRA domain. Emotional factors had broad influence on care burden. FCs with emotional distress were more likely to experience changes to their daily routine (adjusted odds ratio (aOR), 2.54; 95% confidence interval (CI), 1.29~5.02), lack of family support (aOR, 2.27; 95% CI, 1.04~4.97) and health issues (aOR, 5.44; 2.50~11.88). Family functionality clearly reflected a lack of support, and severe family dysfunction was linked to financial issues as well. FCs without religion or comorbid conditions felt more burdened. The caregiving duration and daily caregiving hours significantly predicted FCs' lifestyle changes and physical burden. FCs who were employed, had weak social support or could not visit frequently, had a low self-esteem. Conclusion: This study indicates that it is helpful to understand FCs' emotional status and family functions to assess their care burden. Thus, efforts are needed to lessen their financial burden through social support systems.

Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression (발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법)

  • Cho, Kyung Eun;Yoon, Choon-Sik;Song, Ho-Taek;Lee, Young Han;Lim, Daekeon;Suh, Jin-Suck;Kim, Sungjun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.110-122
    • /
    • 2013
  • Purpose : To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. Conclusion: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.

Comparison of Deep Learning Frameworks: About Theano, Tensorflow, and Cognitive Toolkit (딥러닝 프레임워크의 비교: 티아노, 텐서플로, CNTK를 중심으로)

  • Chung, Yeojin;Ahn, SungMahn;Yang, Jiheon;Lee, Jaejoon
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.1-17
    • /
    • 2017
  • The deep learning framework is software designed to help develop deep learning models. Some of its important functions include "automatic differentiation" and "utilization of GPU". The list of popular deep learning framework includes Caffe (BVLC) and Theano (University of Montreal). And recently, Microsoft's deep learning framework, Microsoft Cognitive Toolkit, was released as open-source license, following Google's Tensorflow a year earlier. The early deep learning frameworks have been developed mainly for research at universities. Beginning with the inception of Tensorflow, however, it seems that companies such as Microsoft and Facebook have started to join the competition of framework development. Given the trend, Google and other companies are expected to continue investing in the deep learning framework to bring forward the initiative in the artificial intelligence business. From this point of view, we think it is a good time to compare some of deep learning frameworks. So we compare three deep learning frameworks which can be used as a Python library. Those are Google's Tensorflow, Microsoft's CNTK, and Theano which is sort of a predecessor of the preceding two. The most common and important function of deep learning frameworks is the ability to perform automatic differentiation. Basically all the mathematical expressions of deep learning models can be represented as computational graphs, which consist of nodes and edges. Partial derivatives on each edge of a computational graph can then be obtained. With the partial derivatives, we can let software compute differentiation of any node with respect to any variable by utilizing chain rule of Calculus. First of all, the convenience of coding is in the order of CNTK, Tensorflow, and Theano. The criterion is simply based on the lengths of the codes and the learning curve and the ease of coding are not the main concern. According to the criteria, Theano was the most difficult to implement with, and CNTK and Tensorflow were somewhat easier. With Tensorflow, we need to define weight variables and biases explicitly. The reason that CNTK and Tensorflow are easier to implement with is that those frameworks provide us with more abstraction than Theano. We, however, need to mention that low-level coding is not always bad. It gives us flexibility of coding. With the low-level coding such as in Theano, we can implement and test any new deep learning models or any new search methods that we can think of. The assessment of the execution speed of each framework is that there is not meaningful difference. According to the experiment, execution speeds of Theano and Tensorflow are very similar, although the experiment was limited to a CNN model. In the case of CNTK, the experimental environment was not maintained as the same. The code written in CNTK has to be run in PC environment without GPU where codes execute as much as 50 times slower than with GPU. But we concluded that the difference of execution speed was within the range of variation caused by the different hardware setup. In this study, we compared three types of deep learning framework: Theano, Tensorflow, and CNTK. According to Wikipedia, there are 12 available deep learning frameworks. And 15 different attributes differentiate each framework. Some of the important attributes would include interface language (Python, C ++, Java, etc.) and the availability of libraries on various deep learning models such as CNN, RNN, DBN, and etc. And if a user implements a large scale deep learning model, it will also be important to support multiple GPU or multiple servers. Also, if you are learning the deep learning model, it would also be important if there are enough examples and references.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

Minor Stress, Coping Skill and Quality of Life in Patients with Hemodialysis (혈액투석 환자들의 Minor Stress, 대처방식 및 삶의 질)

  • Yang, Jae-Won;Lee, Moon-Soo;Park, Sang-Uk;Oh, So-Young;Ko, Young-Hoon;Kwan, Young-Joo;Joe, Sook-Haeng
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.16 no.1
    • /
    • pp.38-46
    • /
    • 2008
  • Objectives : The purpose of this study is to investigate the minor stress in daily life related to undergoing hemodialysis and the relationship between minor stresses, coping skills, and subjective quality of life among the patients with end stage renal disease. Methods : Seventy seven patients on hemodialysis were enrolled in this study. Minor stress was assessed with daily stress inventory-Korean version(K-DSI), ways of coping checklist identified the use of the following coping strategies:problem-focused, seek social support, emotion-focused coping and wishful thinking. Socio-demographic data were obtained and World Health Organization-Quality of Life Scale(brief form) was also administered to subjects. Results : Participants mean age was $55.92{\pm}13.71$ years. The mean of the event, impact and impact/event (I/E) ratio scores of K-DSI were $29.06{\pm}21.57$, $88.69{\pm}75.88$ and $2.92{\pm}1.11$, respectively. These scores were much higher than normative data of K-DSI. Among the 5 categories of this inventory, the scores of cognitive stressors were highest. 5 categories of the inventory showed positive relationship with way of coping subscales, which showed coefficient of correlation between 0.259(p<.01) and 0.495(p<.001). However, no significant correlation was found between minor stress subscales and quality of life. Hemodialysis patients in our study used more emotional-focused coping methods, which was considered as passive way of cope than problem-orientated coping methods. Conclusion : The main findings of this study indicated that patients on hemodialysis showed higher level of perceived minor stress than normal population. The patients treated with hemodialysis tend to use passive way of coping primarily. For assessing the stress in patients on hemodialysis, clinician has to consider both level of perceived minor stress and the ways of coping the patients primarily use.

  • PDF

External Exposure Due to Natural Radionuclides in Building Materials in Korean Dwellings (건축자재내 포함된 천연방사성핵종에 의한 실내 공간의 방사선량 평가)

  • Cho, Yoon Hae;Kim, Chang Jong;Yun, Ju Yong;Cho, Dae-Hyung;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.181-190
    • /
    • 2012
  • Naturally occurring radioactive materials (NORM) in building materials are main sources of external radiation exposure to the general public. The objective of this study was to assess external radiation dose in Korean dwellings due to NORM in concrete walls. Reference room model for dose assessment was made by analyzing room structure and housing scale of Korean dwellings. In addition, dose assessments were made for varying room sizes. Absorbed doses to air and effective dose rates were calculated using radiation transport code MCNPX. Assuming a reference room of $3{\times}4{\times}2.8m^3$, absorbed dose rates in air were 0.80, 0.97, 0.08 nGy $h^{-1}$ per Bq $kg^{-1}$ for uranium series, thorium series, and $^{40}K$, respectively. Effective dose rates were 0.57, 0.69, 0.058 nSv $h^{-1}$ per Bq $kg^{-1}$, respectively. Radiation dose resulting from concrete of ceiling and floor increased with room area while radiation dose from concrete of walls decreased with room area. Therefore, total radiation doses were almost the same for the varying room area from 5 to $30m^2$. Effective dose in Korean dwellings was calculated based on measurement data of NORM concentration in concrete and occupancy fraction of Korean population by location. Annual effective dose was 0.59 mSv assuming that indoor occupancy fraction was 0.89 and concentrations of uranium series, thorium series and $^{40}K$ were 26, 39, 596 Bq $kg^{-1}$, respectively. Finally, annual effective dose in Korean dwellings can be calculated by the following equation: Effective dose=indoor occupancy fraction${\times}8760\;h\;y^{-1}{\times}(0.57C_U+0.69C_{Th}+0.058C_K)$.