• 제목/요약/키워드: assay method

검색결과 2,608건 처리시간 0.027초

Development of HPLC assay method of fusidate sodium tablets

  • Lee, GaJin;Choi, Min;Truong, Quoc-Ky;Mai, Xuan-Lan;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제30권3호
    • /
    • pp.154-158
    • /
    • 2017
  • The Korean Pharmacopoeia (KP XI), British Pharmacopoeia (BP 2013) and Japanese Pharmacopoeia contain monographs for the quality control of raw fusidate sodium and its formulations using high performance liquid chromatography (HPLC). However, the assay method for the determination of fusidate sodium in commercial tablets is titration which is less specific than HPLC. In this study, we present an alternative HPLC method for quantitation of fusidate sodium in tablets. Method validation was performed to determine linearity, precision, accuracy, system suitability, and robustness. The linearity of calibration curves in the desired concentration range was high ($r^2=0.9999$), while the RSDs for intra- and inter-day precision were 0.25-0.37 % and 0.11-0.60 %, respectively. Accuracies ranged from 99.46-100.85 %. Since the system suitability, intermediate-precision and robustness of the assay were satisfactory, this method will be a valuable addition to the Korean Pharmacopoeia (KP XI).

Studies on pharmaceutical assay method using Near Infrared Spectroscopy (NIRS) (II)

  • Kang, Shin-Jung;Yun, Mi-Ok;Lee, Su-Jung;Choi, Hyun-Chul;Kim, Ho-Jeong;Kim, Ji-Yeon
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4113-4113
    • /
    • 2001
  • This study developed effective assay method of pharmaceutical quality control was developed by near-infrared spectroscopy (NIRS). The calibration equation model of assay was developed by 2nd deriviative PLS(Partial Least Squares) regression method with NIRS over the wavelength range from 1100 to 1400nm using diazepam tablets (2mg, 5mg). Although diazepam tablets are made by 5-different manufacture, they have similar formulation. When the correlation was compared with values by NIRS and HPLC, the R-2s and standard error of calibration (SEC) for 2mg were 0.9300 and 0.98%, the R-2s and SEC for 5mg were 0.9165 and 0.63%. The validation of the calibration equation model yield that the R-2s and standard error of prediction (SEP) for 2mg were 0.9611 and 0.995%, the R-2s and SEP for 5mg were 0.9114 and 0.842%. The method was validated on assay method for diazepam tablets by the calibration equation.

  • PDF

컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법 (A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera)

  • 박종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Study of 3-Ketosteroid Dehydrogenase System Using Whole-cell-enzyme from Arthrobacter simplex

  • Park, Eun-Chung;Ryu, Dewey Doo-Young
    • 약학회지
    • /
    • 제21권3호
    • /
    • pp.167-171
    • /
    • 1977
  • A new assay method for delta-l-dehydrogenated-3-ketoco-rticosteroid in the presence of proteinous material or whole-cell-enzyme and 3-ketocorticosteroid has been developed. This method makes use of the linear relationship between the ratio of absorbances at 265 nm and at 242 nm and the fractional concentration of delta-1-3-ketosteroid. Theoretical values were calculated based on the absorbances of proteinous material at fixed concentrations of the 3-ketosteroid and delta-1-dehydrogenated-3-ketosteroid. The values obtained experimentally showed good agreement with the values obtained experimentally showed good agreement with the values theoretically predicted. The new assay method developed for the steroid mixtiure containing proteinous material is of some practical importance. The use of such assay method enables one to determine the enzyme activity and the rate of enzyme reaction or conversion rather quickly, easily and accurately. By the use of this assay method, the reaction kinetics of whole-cell-enzyme has also been studied. It was found that it followed the simple Michaelis-Menten type enzyme kinetics. Also the reversibility of this reaction with actively metabolizing cell was examined. It was found that delta-l-dehydrogenated-3-ketosteroid could not be hydrogenated reversibly to 3-ketosteroid by this enzyme system.

  • PDF

cAMP 신호전달과정을 통한 신규 천연유래물질 펩타이드 유도체의 미백 효능 연구 (Whitening Efficacy Study of Natural Compounds-Peptide Derivatives via cAMP Signaling Pathway)

  • 이혜숙;신경훈;류근석;지경엽;조인식;김한영
    • 대한화장품학회지
    • /
    • 제37권3호
    • /
    • pp.275-282
    • /
    • 2011
  • MC1R의 길항제 역할을 하는 펩타이드와 tyrosinase를 저해하는 효능을 가지는 천연유래 물질을 유도체화하여 신규 미백소재를 개발하였다. 또한 이러한 새로운 기작에 의한 미백 효능을 평가할 수 있는 방법을 cAMP 신호전달 과정을 활용하여 제시하였다. 총 24종의 유도체를 합성하였고, cAMP assay의 결과를 통해 11종의 유도체를 선별하였으며, 선별된 유도체에 대하여 멜라닌 형성 억제 효능을 평가하여 본 평가 방법의 유효성을 확인하였다. 이 과정에서 RW를 서열에 포함하는 펩타이드 유도체가 특별히 멜라닌 형성 억제 효능이 높은 것을 알 수 있었다. 또한, cAMP assay는 MC1R의 antagonist라는 특정 타겟 물질을 디자인한 소재의 스크리닝 방법에는 활용할 수 있음을 알 수 있었다. 하지만, 미백소재로서의 가능성을 확인하기 위해서는 멜라닌 생성저해 시험과 병행하여야 할 것으로 판단된다.

Development of a Redox Dye-Based Rapid Colorimetric Assay for the Quantitation of Viability/Mortality of Pine Wilt Nematode

  • Han, Kyeongmin;Lee, Jaejoon;Shanmugam, Gnanendra;Lee, Sun Keun;Jeon, Junhyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권7호
    • /
    • pp.1117-1123
    • /
    • 2019
  • Control of pine wilt disease, which is caused by pine wilt nematode Bursaphelenchus xylophilus, is heavily dependent on the use of chemicals such as abamectin. Although such chemicals are highly effective, demands for alternatives that are derived preferentially from natural sources, are increasing out of environmental concerns. One of the challenges to discovery of alternative control agents is lack of fast and efficient screening method that can be used in a high-throughput manner. Here we described the development of colorimetric assay for the rapid and accurate screening of candidate nematicidal compounds/biologics targeting B. xylophilus. Contrary to the conventional method, which relies on laborious visual inspection and counting of nematode population under microscope, our method utilizes a redox dye that changes its color in response to metabolic activity of nematode population in a given sample. In this work, we optimized parameters of our colorimetric assay including number of nematodes and amount of redox dye, and tested applicability of our assay for screening of chemicals and biologics. We demonstrated that our colorimetric assay can be applied to rapid and accurate quantification of nematode viability/mortality in a nematode population treated with candidate chemicals/biologics. Application of our method would facilitate high-throughput endeavors aiming at finding environment-friendly control agents for deadly disease of pine trees.

Real-time PCR을 이용한 돼지써코바이러스 감염증 진단법 연구 (Rapid detection and quantification of porcine circovirus type 2 (PCV 2) DNA in Real-time PCR)

  • 김은경;황보원;이종민;손병국;박호정;김도경
    • 한국동물위생학회지
    • /
    • 제32권4호
    • /
    • pp.299-306
    • /
    • 2009
  • Assay for the detection and quantification of porcine circovirus type 2 (PCV 2) with the real-time PCR were developed. TaqMan probe real-time using a set of primer/probe was developed for detection of PCV 2. In this study we applied real-time PCR assay to 320 samples, collected from pig farms. In 151 of 320 samples, PCV 2 DNA was detected by conventional PCR assay. All samples positive for PCV 2 DNA in conventional PCR assay were also positive in Real-time PCR assay, but 69 of 169 samples that tested negative for PCV 2 DNA in conventional assay were tested positive in TaqMan probe real-time PCR assay. The test of TaqMan probe real-time PCR resulted in detection and quantification limits of 101 copies per sample. TaqMan probe real-time PCR assay increased the number of samples in which PCV 2 was detected by 21%. TaqMan probe real-time PCR assay is very efficient method in contrast to the conventinal PCR, becoming increasingly important method for gene analysis.

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • 제28권3호
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

수두바이러스의 정량에 있어서 Solid-overlay Standard Plaque Assay와 Immunofocus Assay의 효용성 비교 연구 (Comparative Study of the Standard Plaque Assay with Solid-overlay and Immunofocus Assay for Varicella-zoster Virus Titration)

  • 이화경;정용석
    • 대한바이러스학회지
    • /
    • 제30권1호
    • /
    • pp.61-70
    • /
    • 2000
  • Standard plaque assay using agarose-overlay has long been used for titration of many infectious virus particle. Plaque assay for the titration of varicella-zoster virus and its live vaccine requires three intermittent agarose overlay to visualize plaques. Overall procedure of the assay takes at least nine days from virus inoculation and microbe contamination including fungi is frequently accompanied during incubation period. We studied whether an immunofocus assay in conjunction with peroxidase-mediated immunohistochemical reaction may replace the standard plaque assay for the virus titration by comparing the two methods. A linear relationship was observed between number of foci and virus dilution. The number of foci in a given dilution of virus appeared a little higher than counted plaques formed in standard plaque assay. Independent titration results obtained from two assay methods for a given dilution of virus demonstrated a strong correlation ($r^2=0.99$). Foci of virus infected cells as revealed by the enzyme reaction could be counted either 4 days post-infection (p.i.) under low magnification (40X) microscopy, or 6 days p.i. by naked eye observation. Larger size of cell cuture plate, virus adsorption at $35^{\circ}C$, and 10% FBS in diluent appeared to be better conditions for the assay. Immunofocus assay will be an effective and dependable titration method for varicella-zoster virus and its live vaccine in place of the standard plaque assay in respect to accuracy, costs, and experimental convenience.

  • PDF

디페메린염산염 시험에 사용되는 유해시약인 수은 대체 시험법의 개발 (Development of alternative titration method without mercuric acetate for the assay of difemerine hydrochloride in Korean Pharmaceutical Codex)

  • 전상설;김경호
    • 분석과학
    • /
    • 제27권4호
    • /
    • pp.196-200
    • /
    • 2014
  • 국가 공정서 중 하나인 대한민국약전외의약품 기준에는 디페메린염산염의 정량법으로 유해시약인 아세트산수은을 사용하는 비수적정법이 수재되어 있다. 본 연구에서는 디페메린염산염의 환경 친화적인 대체 시험법으로 보다 안전하고 효율적인 친환경용매인 에탄올을 사용하는 중화적정법을 개발하고, 분석법을 검증하였다. 디페메린염산염의 직선성은 상관계수(r)가 0.999 이상을 나타내었고, 정확도는 99.10~99.71%, 정밀도는 0.64% 이하로 나타났다. 개발된 시험법은 대한민국약전외의약품 기준의 개정에 기여가 될 것이다.