• Title/Summary/Keyword: artifact analysis

Search Result 282, Processing Time 0.028 seconds

Image Enhancement Using Human Visual Perception (인간 시각의 인지 특성을 이용한 영상 화질 향상 방법)

  • Bang, Seangbae;Kim, Wonha
    • Journal of Broadcast Engineering
    • /
    • v.23 no.2
    • /
    • pp.206-217
    • /
    • 2018
  • We develop the signal processing method for adaptive implementing direction of signal and the frequency sensitivity of human visual system(HVS). Existing multiband energy scaling method makes ringing artifact because it does not consider signal direction. To solve this problem, we use block gradient for signal direction in addition to existing method. And we use the fact that frequency component of signal is more sensitive than value of signal over human eyes. we enhance the signal according to contrast sensitivity function(CSF) which is the model of frequency sensitivity of human eye. Compared that the existing analysis models only improve the efficiencies in the existing systems, the developed method can process the image signals to be more desirable and suitable to HVS.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

Digital Forensic Indicators of Compromise Format(DFIOC) and Its Application (디지털 포렌식 기반의 침해 지표 포맷 개발 및 활용 방안)

  • Lee, Min Wook;Yoon, Jong Seong;Lee, Sang Jin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.4
    • /
    • pp.95-102
    • /
    • 2016
  • Computer security incident such as confidential information leak and data destruction are constantly growing and it becomes threat to information in digital devices. To respond against the incident, digital forensic techniques are also developing to help digital incident investigation. With the development of digital forensic technology, a variety of forensic artifact has been developed to trace the behavior of users. Also, a diversity of forensic tool has been developed to extract information from forensic artifact. However, there is a issue that information from forensic tools has its own forms. To solve this problem, it needs to process data when it is output from forensic tools. Then it needs to compare and analyze processed data to identify how data is related each other and interpret the implications. To reach this, it calls for effective method to store and output data in the course of data processing. This paper aims to propose DFIOC (Digital Forensic Indicators Of Compromise) that is capable of transcribing a variety of forensic artifact information effectively during incident analysis and response. DFIOC, which is XML based format, provides "Evidence" to represent various forensic artifacts in the incident investigation. Furthermore, It provides "Forensic Analysis" to report forensic analysis result and also gives "Indicator" to investigate the trace of incidence quickly. By logging data into one sheet in DFIOC format for forensic analysis process, it is capable of avoiding unnecessary data processing. Lastly, since collected information is recorded in a normalized format, data input and output becomes much easier as well as it will be convenient to use for identification of collected information and analysis of data relationship.

Isolation and Identification of Phenolic Tertiary and Quaternary Alkaloids from Thalictrum uchiyamai (한국산 Thalictrum속 식물의 성분연구(II) 자주꿩의 다리 뿌리의 성분)

  • 이인란
    • YAKHAK HOEJI
    • /
    • v.28 no.3
    • /
    • pp.185-190
    • /
    • 1984
  • Protothalipine colorless needle crystal, mp $195-6^{\circ}$, $C_{21}H_{25}NO_{5}$) and jatrorrhizine chloride (Base A, orange needle crystal, mp $198^{\circ}$) are identified by chemical, spectral analysis, and comparison with authentic sample. Base B (reddish crystal, mp $192-4^{\circ}$) might be a artifact substance, which was changed from the jatrorrhizine chloride. Base C (yellowish needle crystal, mp $228~230^{\circ}$) and Base D (reddish needle crystal, mp $211~213^{\circ}$) were assumed to be thalifendine chloride, desoxythalidastine chloride by phytochemical and spectral analysis respectively.

  • PDF

Digital Camera Identification Based on Interpolation Pattern Used Lens Distortion Correction (디지털 카메라의 렌즈 왜곡 보정에 사용된 보간 패턴 추출을 통한 카메라 식별 방법)

  • Hwang, Min-Gu;Kim, Dong-Min;Har, Dong-Hwan
    • Journal of Internet Computing and Services
    • /
    • v.13 no.3
    • /
    • pp.49-59
    • /
    • 2012
  • Throughout developing digital technology, reproduction of image is growing better day by day. And at the same time, diverse image editing softwares are developed to manage images easily. In the process of editing images, those programs could delete or modify EXIF files which have the original image information; therefore images without the origin source are widely spread on the web site after editing. This matter could affect analysis of images due to the distortion of originality. Especially in the court of law, the source of evidence should be expressed clearly; therefore digital image EXIF file without deletion or distortion could not be the objective evidence. In this research, we try to trace the identification of a digital camera in order to solve digital images originality, and also we focus on lens distortion correction algorism which is used in digital image processing. Lens distortion correction uses mapping algorism, and at this moment it also uses interpolation algorism to prevent aliasing artifact and reconstruction artifact. At this point interpolation shows the similar mapping pattern; therefore we want to find out the interpolation evidence. We propose a minimum filter algorism in order to detect interpolation pattern and adjust the same minimum filter coefficient in two areas; one has interpolation and the second has no interpolation. Throughout DFT, we confirm frequency character between each area. Based on this result, we make the final detection map by using differences between two areas. In other words, thereby the area which has the interpolation caused by mapping is adjusted using minimum filter for detection algorism; the second area which has no interpolation tends to different frequency character.

Application Study of Dry-ice Pellet Cleaning for Removing Oil Paint and Lacquer of Outdoor Metal Artifacts (Dry-ice Pellet Cleaning 적용 옥외 금속문화재 표면 페인트 및 유성물질 제거방법 비교 연구)

  • Lee, Jee-Eun;Cho, Nam-Chul;Lee, Jong-Myoung;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.28 no.3
    • /
    • pp.217-228
    • /
    • 2012
  • Damage of cultural properties happens variously. Particularly, the surface damage of metal cultural properties exposed outdoors lowers historical and art historical value of artifact by artificial damage such as paint, scribbling containing oily material and so on. Therefore, this study compared dry-ice pellet cleaning with poultice when clearing paint and oily material environment-friendly, harmlessly to humans and without damage of artifact. As the result of experiment, when clearing those (paint and oily material) by poultice, oily paint was cleared, but there were spots of metal surface. Also, Lacquer spray wasn't well cleared, and resin came off the surface of artifact. When clearing those by dry-ice pellet cleaning, oil paint was cleanly cleared without surface damage of artifact according to Stereoscopic microscope observation, color-measurement, FT-IR, SEM analysis. Also, lacquer spray seemed to be cleared with the naked eye, but there were minute particles on surface according to the result of SEM observation. Consequently, we could confirm possibility of dry-ice pellet cleaning substitution.

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

A Method for the Reduction of Skin Marker Artifacts During Walking : Application to the Knee

  • Mun, Joung-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.825-835
    • /
    • 2003
  • Previous studies have demonstrated the importance of joint angle errors mainly due to skin artifact and measurement errors during gait analysis. Joint angle errors lead to unreliable kinematics and kinetic analyses in the investigation of human motion. The purpose of this paper is to present the Joint Averaging Coordinate System (JACS) method for human gait analysis. The JACS method is based on the concept of statistical data reduction of anatomically referenced marker data. Since markers are not attached to rigid bodies, different marker combinations lead to slightly different predictions of joint angles. These different combinations can be averaged in order to provide a "best" estimate of joint angle. Results of a gait analysis are presented using clinically meaningful terminology to provide better communication with clinical personal. In order to verify the developed JACS method, a simple three-dimensional knee joint contact model was developed, employing an absolute coordinate system without using any kinematics constraint in which thigh and shank segments can be derived independently. In the experimental data recovery, the separation and penetration distance of the knee joint is supposed to be zero during one gait cycle if there are no errors in the experimental data. Using the JACS method, the separation and penetration error was reduced compared to well-developed existing methods such as ACRS and Spoor & Veldpaus method. The separation and penetration distance ranged up to 15 mm and 12 mm using the Spoor & Veldpaus and ACRS method, respectively, compared to 9 mm using JACS method. Statistical methods like the JACS can be applied in conjunction with existing techniques that reduce systematic errors in marker location, leading to an improved assessment of human gait.

Computer-Aided Detection of Clustered Microcalcifications using Texture Analysis and Neural Network in Digitized X-ray Mammograms (X-선 유방영상에서 텍스처 분석과 신경망을 이용한 군집성 미세석회화의 컴퓨터 보조검출)

  • 김종국;박정미
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • Clustered microcalcifications on X-ray mammograms are an important sign for early detection of breast cancer. This paper proposes a computer-aided diagnosis method for the detection of clustered microcalcifications and marking their locations on digitized mammograms. The proposed detection method consists of the region of interest (ROI) selection, the film-artifact removal, the surrounding texture analysis method for the detection of clustered microcalcifications, which is based on the second-order histogram in two nested surrounding regions on the current pixel. This paper also describes the effectiveness of the proposed film-artifact removal filter in terms of the classification performance with the receiver operating-characteristics(ROC) analysis. A three-layer backpropagation neural network is employed as a classifier. The appropriate marking for the locations of clustered microcalcifications can be used to alert radiologists to locations of suspicious lesions.

  • PDF