• Title/Summary/Keyword: artery stenosis

Search Result 498, Processing Time 0.031 seconds

Animal Model for Sequential Bilateral Reimplantation of the Lung in Dog (순차적 자가 양측 폐재식을 위한 황견에서의 실험 model -2례 보고)

  • 이두연;김해균
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.733-738
    • /
    • 1997
  • Sequential bilateral lung transplantation may result in a variety of perioperative and postoperative complications, showing high perioperative morbidity and mortality rates. This research was performed to investigate the hemodynamic changes in adult mongrel dogs after bilateral reimplantation, two methods preferred for avoiding or minimizing graft rejection. The anterior portion of the pulmonary artery and the left atrium proximal to the superior and the inferior pulmonary veins were resected out and then re-anastomosed one hour later to prevent torsion or stenosis of the anastomotic site and the formation of a thrombosis in the left atrium. An everted suture technique was employed for the left atrium; An hour after the division, however, the main bronchus was tightly anastomose by interrupted sutures of No. 4-0 prolene in a telescope method. A modified I-C solution mixed with PGEI was infused into the cut portion of the pulmonary artery at the rate of 15 mllkglmin and at a pressure of 40 cmH20 for a total dosage of 70 mlfkg in order to preserve the transected lung. Topical cooling using wet gauzes soaked with cold I-C solution was performed for one hour to prevent ischemic lung injury. The above procedures are considered to be beneficial for achieving a satisfactory outcome for bilateral lung reimplantation.

  • PDF

Surgical Experience of Ascending Aorta and Aortic Valve Replacement in Patient with Calcified Aorta

  • Chung, Sur-Yeun;Park, Pyo-Won;Choi, Min-Suk;Cho, Seong-Ho;Sung, Ki-Ick;Lee, Young-Tak;Jeong, Jae-Han
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Background: The conventional method of aortic cross-clamping is very difficult and increases the risk of cerebral infarct due to embolism of the calcified aorta in these patients. Accordingly, we analyzed our experience with 11 cases of ascending aorta and aortic valve replacement with hypothermic circulatory arrest. Materials and Methods: From January 2002 to December 2009, 11 patients had ascending aorta and aortic valve replacement with hypothermic arrest at our hospital. We performed a retrospective study. Results: There were 5 males and 6 females, with a mean age of 68 years (range, 44 to 82 years). Eight patients had aortic stenosis, and 3 patients had aortic regurgitation. An aortic cannula was inserted into the right axillary artery in 3 patients and ascending aorta in 6 patients. Two patients with aortic regurgitation had a remote access perfusion catheter inserted though the right femoral artery. The mean cardiopulmonary bypass time was 180 minutes (range, 110 to 306 minutes) and mean hypothermic circulatory arrest time was 30 minutes (range, 20 to 48 minutes). The mean rectal temperature during hypothermic circulatory arrest was $21^{\circ}C$ (range, $19^{\circ}C$ to $23^{\circ}C$). No patient had any new onset of cerebral infarct or cardiovascular accident after surgery. There was no hospital mortality. Early complications occurred in 1 patient who needed reoperation due to postoperative bleeding. Late complications occurred in 1 patient who underwent a Bentall operation due to prosthetic valve endocarditis. The mean follow-up duration was 32 months (range, 1 month to 8 years) and 1 patient died suddenly due to unknown causes after 5 years. Conclusion: Patients with a calcified aorta can be safely treated with a technique based on aorta and aortic valve replacement under hypothermic circulatory arrest.

Early Results of Extracardiac Fontan Operation (심장외폰탄수술의 조기성적)

  • 김웅한;정도현;김수철;전홍주;이창하;김욱성;오삼세;정철현;나찬영
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.650-659
    • /
    • 1998
  • Between August 1996 and August 1997, 22 patients underwent extracardiac Fontan operations. The basic diagnoses included univentricular heart of the right ventricular type (n=12); univentricular heart of the left ventricular type (n=4); tricuspid atresia (n=4); left isomerism, transposition of great arteries, ventricular septal defect and pulmonary stenosis (n=1); and criss-cross heart with uneven ventricle (n=1). The median age of the 14 men and 8 women was 29 months (range from 21 months to 26 years). Previous procedures included bidirectional cavopulmonary shunt (n=15, interval=15.6$\pm$3.4 months), Kawashima operation (n=4, interval=37.5$\pm$20 months), and classic Glenn shunt (n=1, interval=14 years). In 2 patients, extracardiac Fontan operations were done without any previous procedures. A 16- to 22-mm flexible Gore-Tex tube graft (n=18), Hemashield graft (n=3), or, alternatively, a nonvalved aortic allograft (n=1) was cut and anastomosed end-to-end between inferior vena cava and undersurface of pulmonary artery using Gore-Tex or Prolene suture in a running fashion. In risk Fontan patients (n=12), a communication between the extracardiac conduit and the right atrium was constructed. In the most 13 recent patients, the procedures were done without cross-clamping of the aorta and with a beating heart. Operative mortality was 9.1% (n=2). Complications included persistent chest tube drainage for more than 7 days (n=5), chorea (n=2), and low cardiac output (n=1). There were no late deaths. Follow-up echocardiogram (mean: 6 months) demonstrated satisfactory hemodynamic results in the surviving 20 patients. Potential advantages of this technique consist of minimization of surgical manipulation of atrial tissue, reduction or elimination of myocardial ischemia, creationof a uniform and stable inferior vena cava-to-pulmonary artery conduit, and increased flexibility and safety in certain high-risk patients such as those with increased pulmonary vascular resistance, pulmonary hypertension, and impaired ventricular function. Further investigations during a longer follow-up are needed to confirm the intermediate and long-term results, especially the reduction of late atrial arrhythmias.

  • PDF

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF

A case of Smith-Lemli-Opitz syndrome diagnosed by identification of mutations in the 7-dehydrocholesterol reductase (DHCR7) gene (7-dehydrocholesterol reductase (DHCR7) 변이로 진단된 Smith-Lemli-Opitz 증후군 1예)

  • Park, Mee Rim;Ko, Jung Min;Cheon, Chong-Keun;Kim, Gu-Hwan;Yoo, Han-Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1236-1240
    • /
    • 2008
  • Smith-Lemli-Opitz syndrome (SLOS) is a rare, autosomal recessive disease caused by an inborn error in cholesterol synthesis. Patients with this disease suffer from multiple malformations due to reduced activity of 7-dehydrocholesterol reductase (DHCR7), which increases 7-dehydrocholesterol (7DHC) and 8-dehydrocholesterol (8DHC) concentrations and decreases cholesterol concentration in body fluids and tissue. The SLOS phenotypic spectrum ranges from a mild disorder with behavioral and learning problems to a lethal disease characterized by multiple malformations. Here, we describe a newborn male with ambiguous genitalia who was diagnosed to have type II SLOS during the neonatal period. A clinical examination revealed low levels of unconjugated estriol in the maternal serum, and a variety of fetal ultrasound anomalies, including prenatal growth retardation. After birth, the infant was diagnosed to have congenital heart disease (Tetralogy of Fallot with severe pulmonary artery stenosis), cleft lip and palate, micrognathia, postaxial polydactyly, ambiguous genitalia, and cataracts. Clinical investigation revealed extremely low plasma cholesterol levels and the presence of mutation (homozygote of p.Arg352Gln) in the DHCR7 gene. The patient underwent palliative heart surgery (to widen the pulmonary artery) and received intravenous lipid supplementation. Cholesterol levels increased slightly, but not to normal values. The patient died from cardiopulmonary failure and sepsis 72 days after birth. This report provides the first description of a Korean patient with SLOS confirmed by verification of DHCR7 gene mutation and illustrates the need for early recognition and appropriate diagnosis of this disease.

Histologic Changes of the Immunologically Untreated Xenogenic Valved Conduit (면역학적 처리 없는 이종 심장 판막 도관의 조직학적 변화에 관한 연구)

  • Sung, Ki-Ick;Seo, Jeong-Wook;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.1-7
    • /
    • 2007
  • Backgound: It has been shown that the endothelium of cardiac valves and adjacent great vessels have a reduced immune reaction compared to other vessels. We investigated the clinical feasibility of using immunologically untreated xenogenic valves, in a pig-to-goat pulmonary valve conduit implantation model. Material and Method: Porcine pulmonary valve conduits were prepared without specific immunologic treatment and implanted into the right ventricular outflow tract of goats while undergoing cardiopulmonary bypass. Two goats each were assigned to the following observation time intervals: one day, one week, three months, six months and twelve months. Echo-cardiographic examinations were performed prior to sacrifice of the goat to evaluate pulmonary valve function. After the xenograft specimens were retrieved, histological changes were evaluated microscopically. Result: Ten of the twelve animals survived the predetermined observation time intervals. Aneurysmal dilatations, of the anterior wall of the implanted pulmonary artery, were observed at each of three and twelve month-survival animals. A variable degree of pulmonary valve regurgitation was observed on echocardiography. However, valve stenosis, thrombotic occlusion and vegetation were not seen. Microscopically, the nuclei of the donor tissue disappeared as a result of pyknosis and karyolysis; however the three components of the implanted xenografts (the pulmonary artery, the valve and the infundibulum) were gradually replaced by host cells over time, while maintaining their structural integrity. Conclusion: Immunologically untreated xenogenic pulmonary valve conduits were replaced by host cells with few observed clinical problems in a pig to goat pulmonary valve implantation model. Therefore, they might be an alternative bioprosthesis option.

Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes

  • Kwon, Min-Yong;Ko, Young San;Kwon, Sae Min;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.801-815
    • /
    • 2022
  • Objective : To evaluate the stent apposition of a low-profile visualized intraluminal support (LVIS) device in distal internal carotid artery (ICA) aneurysms, examine its correlation with clinical and angiographic outcomes, and determine the predictive factors of ischemic adverse events (IAEs) related to stent-assisted coiling. Methods : We retrospectively analyzed a prospectively maintained database of 183 patients between January 2017 and February 2020. The carotid siphon from the cavernous ICA to the ICA terminus was divided into posterior, anterior, and superior bends. The anterior bends were categorized into angled (V) and non-angled (C, U, and S) types depending on the morphology and measured angles. Complete stent apposition (CSA) and incomplete stent apposition (ISA) were evaluated using unsubtracted angiography and flat-panel detector computed tomography. Dual antiplatelet therapy with aspirin 200 mg and clopidogrel 75 mg was administered. Clopidogrel resistance was defined as fewer responders (≥10%, <40%) and non-responders (<10%) based on the percent inhibition (%INH) of the VerifyNow system. These were counteracted by a dose escalation to 150 mg for fewer responders or substitution with cilostazol 200 mg for non-responders. IAEs included intraoperative in-stent thrombosis, transient ischemic attack, cerebral infarction, and delayed in-stent stenosis. A multivariate logistic regression analysis was used to determine the predictive factors for ISA and IAEs. Results : There were 33 ISAs (18.0%) and 27 IAEs (14.8%). The anterior bend angle was narrower in ISA (-4.16°±25.18°) than in CSA (23.52°±23.13°) (p<0.001). The V- and S-types were independently correlated with the ISA (p<0.001). However, treatment outcomes, including IAEs (15.3% vs. 12.1%), aneurysmal complete occlusion (91.3% vs. 88.6%), and recanalization (none of them), did not differ between CSA and ISA (p>0.05). The %INH of 27 IAEs (13.78%±14.78%) was significantly lower than that of 156 non-IAEs (26.82%±20.23%) (p<0.001). Non-responders to clopidogrel were the only significant predictive factor for IAEs (p=0.001). Conclusion : The angled and tortuous anatomical peculiarity of the carotid siphon caused ISA of the LVIS device; however, it did not affect clinical and angiographic outcomes, while the non-responders to clopidogrel affected the IAEs related to stent-assisted coiling.

Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction

  • Jung Hee Hong;Eun-Ah Park;Whal Lee;Chulkyun Ahn;Jong-Hyo Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1165-1177
    • /
    • 2020
  • Objective: To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. Materials and Methods: We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age, 67.0 ± 10.8 years) who had undergone both CCTA and invasive coronary artery angiography from March 2017 to June 2018. All included patients underwent CCTA with iterative reconstruction (ADMIRE level 3, Siemens Healthineers). We developed a deep learning based denoising technique (ClariCT.AI, ClariPI), which was based on a modified U-net type convolutional neural net model designed to predict the possible occurrence of low-dose noise in the originals. Denoised images were obtained by subtracting the predicted noise from the originals. Image noise, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively calculated. The edge rise distance (ERD) was measured as an indicator of image sharpness. Two blinded readers subjectively graded the image quality using a 5-point scale. Diagnostic performance of the CCTA was evaluated based on the presence or absence of significant stenosis (≥ 50% lumen reduction). Results: Objective image qualities (original vs. denoised: image noise, 67.22 ± 25.74 vs. 52.64 ± 27.40; SNR [left main], 21.91 ± 6.38 vs. 30.35 ± 10.46; CNR [left main], 23.24 ± 6.52 vs. 31.93 ± 10.72; all p < 0.001) and subjective image quality (2.45 ± 0.62 vs. 3.65 ± 0.60, p < 0.001) improved significantly in the denoised images. The average ERDs of the denoised images were significantly smaller than those of originals (0.98 ± 0.08 vs. 0.09 ± 0.08, p < 0.001). With regard to diagnostic accuracy, no significant differences were observed among paired comparisons. Conclusion: Application of the deep learning technique along with iterative reconstruction can enhance the noise reduction performance with a significant improvement in objective and subjective image qualities of CCTA images.

Clinical Results of Drug-Coated Balloon Treatment in a Large-Scale Multicenter Korean Registry Study

  • Sang Yeub Lee;Yun-Kyeong Cho;Sang-Wook Kim;Young-Joon Hong;Bon-Kwon Koo;Jang-Whan Bae;Seung-Hwan Lee;Tae Hyun Yang;Hun Sik Park;Si Wan Choi;Do-Sun Lim;Soo-Joong Kim;Young Hoon Jeong;Hyun-Jong Lee;Kwan Yong Lee;Eun-Seok Shin;Ung Kim;Moo Hyun Kim;Chang-Wook Nam;Seung-Ho Hur;Doo-Il Kim; Stent Failure Research Group (SFR) Drug coated balloon (DCB) registry investigators
    • Korean Circulation Journal
    • /
    • v.52 no.6
    • /
    • pp.444-454
    • /
    • 2022
  • Background and Objectives: The aim of this study was to demonstrate the efficacy and safety of treatment with drug-coated balloon (DCB) in a large real-world population. Methods: Patients treated with DCBs were included in a multicenter observational registry that enrolled patients from 18 hospitals in Korea between January 2009 and December 2017. The primary outcome was target lesion failure (TLF) defined as a composite of cardiovascular death, target vessel myocardial infarction, and clinically indicated target lesion revascularization at 12 months. Results: The study included 2,509 patients with 2,666 DCB-treated coronary artery lesions (1,688 [63.3%] with in-stent restenosis [ISR] lesions vs. 978 [36.7%] with de novo lesions). The mean age with standard deviation was 65.7±11.3 years; 65.7% of the patients were men. At 12 months, the primary outcome, TLF, occurred in 179 (6.7%), 151 (8.9%), 28 (2.9%) patients among the total, ISR, and de novo lesion populations, respectively. A history of hypertension, diabetes, acute coronary syndrome, previous coronary artery bypass graft, reduced left ventricular ejection fraction, B2C lesion and ISR lesion were independent predictors of 12 months TLF in the overall study population. Conclusions: This large multicenter DCB registry study revealed the favorable clinical outcome of DCB treatment in real-world practice in patient with ISR lesion as well as small de novo coronary lesion.

Truncus Arteriosus associated with Interrupted Aortic Arch (대동맥궁 단절을 동반한 동맥간)

  • Kim Kwan Chang;Choi Sae Hoon;Jang Woo Sung;Yeo In Gwon;Kim Woong-Han
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.852-855
    • /
    • 2005
  • A 85-day-old infant was successfully operated on for truncus arteriosus (type I) with interrupted aortic arch (type A) using one-stage anterior approach without circulatory arrest. Aortic arch was reconstructed by direct anastomosis of ascending aorta and descending aorta with regional perfusion and continuity of right ventricle to pulmonary artery was established with $Shelhigh^{circledR}$ pulmonic conduit. The patient experienced left bronchus compression by descending aorta immediately postoperatively, which was improved with positional change and physiotherapy. The patient had reoperation due to stenosis of valved conduit at 13 months later. The patient is currently well under follow-up of 14 months from initial repair.