발.변전용 폴리머 피뢰기의 기밀특성에 따른 신뢰성 평가 (Reliability Evaluation of Polymer Arrester with Sealing Integrity for Station and Substation)

  • 유대훈;이운용;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.326-327
    • /
    • 2006
  • The paper describes the development of arrester for 154kV class power station and substation. The arrester employs silicone insulating materials for Its housing, instead of the conventional porcelain housing. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters for ultra high voltage is investigated with moisture ingress test. The diagnostic techniques are discusses, including watt loss, partial discharge, AC leakage current, 1mA DC voltage and residual voltage.

  • PDF

직렬 갭 피뢰기의 흡습시 전극표면의 변화 및 특성 (Characteristics and Change of Electrode Surface in Moisture Absorption on the Series Gap Surge Arrester)

  • 조한구;김향숙
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1172-1175
    • /
    • 2003
  • The characteristics and change of electrode surface about Gap type surge arrester for protect DC subway rail were investigated with moisture absorption. Compared that tested about DC/AC discharge commencement voltage, residual voltage, Impulse, square wave impulse for DC rail surge arrester about Gap type surge arrester of moisture absorption state. The AC discharge commencement voltage acted greatly effect of moisture absorption than the DC discharge commencement voltage test.

  • PDF

폴리머 피뢰기의 방압구조 및 특성 (Characteristics of polymer arrester with pressure relief structure)

  • 한동희;조한구;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1109-1112
    • /
    • 2004
  • This study reports on the pressure relief design and braided composite of surge arrester. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. As a solution, this study describes pressure relief design performance of arresters with braided composite module. In general, braided composite has Potential for improved impact and delamination resistance. Manufacturing processes of the braided composite could also be automated and could potentially lead to lower costs. Therefore, in consideration of characteristics of pressure relief for polymer arrester, the fabric pattern of braided composite was decided. And Polymer arrester module was manufactured with braid. The mechanisms of pressure occurrence and relief were investigated basically by analyzing arc energy and the correlation between thermal shock and indoor pressure in pressure relief test.

  • PDF

ZnO 피뢰기의 Pressure relief 기술 분석 (The Analysis of Pressure Relief Technology for ZnO Arrester)

  • 김인성;한세원;조한구;윤형준;김홍순;박승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1450-1452
    • /
    • 1998
  • The chief advantage of polymer arrester, from a handling viewpoint, design of pressure relief, anti-contamination, electrical failuer was reduced by polymer arrester. The life expectancy of polymer arrester depend on a number of design factor. This paper introduced and study : new material housing (silicone composite, EPDM, EPA...), cap type sealing structure, knuckle type electrode, stress relief housing, supporting insulator and sub parts, of polymer arrester.

  • PDF

피뢰설비 열화진단 전문가 시스템의 설계 방법론 (Design Methodology of Expert System for aging diagnosis of Arrester)

  • 김태진;류길수;길경석;성창규;김일권;박종일;원라경
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.69-70
    • /
    • 2006
  • The arrester's condition is related directly to protected equipment's safety. The most important is, therefore, arrester aging diagnosis. In this study, arrester aging diagnosis expert system is implemented to use JESS shell-engine and the leakage current detection technique.

  • PDF

송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성 (Characteristics of Lightning Impulse Current of Zno Block for Transmission Line Arrester with External Gap)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2009
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters ate impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

뇌서지로 인한 피뢰기 열화시 과도상태 분석 (Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge)

  • 임성용;김규호;이상봉;김수배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

18kV 배전용 피뢰기의 누설전류 분석 (Leakage Current Analysis of 18 kV Lighting Arrester)

  • 박정남;이용희;신양섭;서정민;장수형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1906-1908
    • /
    • 2002
  • In general, ZnO lighting arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage. In addition, since the resistive leakage current caused by deterioration of ZnO lighting arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. So, in this paper, we presents a leakage current measuring and analysis system of 18[kV] ZnO lighting arrester.

  • PDF

브레이드 복합재료를 이용한 피뢰기 모듈 제조에 관한 연구 (Manufacture of arrester module using braided composite materials)

  • 한동희;조한구;한세원;박기호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1467-1469
    • /
    • 2002
  • This paper aims to investigate the characteristics of braided thermoplastic and thermosetting composite and pressure relief for polymer arrester. In general, braided composite has potential for improved impact and delamination resistance. Manufacturing processes of the braided composite could also be automated and could potentially lead to lower costs. Therefore, in consideration of characteristics of pressure relief for polymer arrester, the fabric pattern of braided composite was studied. And polymer arrester module was manufactured with braid.

  • PDF

고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석 (The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions)

  • 김인성;한세원;조한구;소진중;김형식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF