• 제목/요약/키워드: area specific flow rate

검색결과 85건 처리시간 0.026초

Runner Design and Internal Flow Characteristics Analysis for an Ns=200 Francis Hydro Turbine Model

  • Hwang, Yeong-Cheol;Chen, Zhenmu;Choi, Young-Do;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권8호
    • /
    • pp.698-703
    • /
    • 2016
  • Francis hydro turbines have been most widely used throughout the world because of their wide range of head and flow rate applications. In most applications, they are used for high heads and flow rates. Currently, Korea is developing technology for Francis hydro turbine design and manufacture. In order to understand the internal details of Francis hydro turbines further, a new Francis turbine model runner is designed and model internal flow characteristics are investigated. The specific speed of the Francis hydro turbine model runner is $Ns=200m-kW-min^{-1}$. The runner blade is designed successfully according to the port area and one-dimensional loss analysis. The best efficiency point of the Francis hydro turbine model achieves 90% at the design condition. CFD analysis yields a hill chart of the Francis hydro turbine model for use in predicting performance.

허용 부하량 산정을 위한 저수유량 산정 방안 (Calculation of low flow for estimating TMDL)

  • 정윤민;권재혁;강상혁
    • Spatial Information Research
    • /
    • 제17권2호
    • /
    • pp.223-239
    • /
    • 2009
  • 우리나라 중소규모의 대부분 하천의 경우 유량 자료의 부족 또는 미계측 지역으로 인하여 효율적인 저수유량 산정이 어려운 실정이다. 따라서 본 연구의 목적은 수계별 환경용량을 고려한 허용부하량 산정을 위해 면적함수 관계식을 이용한 저수유량의 산정방안을 제시하는 것이다. 이를 위해 남한강 상류 지역의 유역면적 $606km^2$인 주천강 유역과 미계측 유역면적 $4,551km^2$인 옥동천 합류 후인 한강 유역을 시험하천으로 선정하였다. 적용결과, 주천 하류부의 저수 유량은 $1.9m^3/s$로, 미계측 유역인 옥동천과 한강의 합류 후의 저수유량은 $20.7m^3/s$로 계산되었다. 이를 영월군에서 고려하고 있는 BOD목표치 1.0-1.2mg/l로 계획하면 허용부하량은 각각 164-197kg/day 및 1,788-2,146kg/day로 추정되었다. 본 연구에서 제시한 허용부하량 산정방법은 자료가 충분하지 않은 유역이나 미계측 유역에 대해 유용하게 이용될 것으로 기대한다.

  • PDF

H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구 (A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site)

  • 한정상
    • 자원환경지질
    • /
    • 제27권3호
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF

Fretting Wear Mechanisms of Zircaloy-4 and Inconel 600 Contact in Air

  • Kim, Tae-Hyung;Kim, Seock-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1274-1280
    • /
    • 2001
  • The fretting wear behavior of the contact between Zircaloy-4 tube and Inconel 600, which are used as the fuel rod cladding and grid, respectively, in PWR nuclear power plants was investigated in air. In the study, number of cycles, slip amplitude and normal load were selected as the main factors of fretting wear. The results indicated that wear increased with load, slip amplitude and number of cycles but was affected mainly by the slip amplitude. SEM micrographs revealed the characteristics of fretting wear features on the surface of the specimens such as stick, partial slip and gross slip which depended on the slip amplitude. It was found that fretting wear was caused by the crack generation along the stick-slip boundaries due to the accumulation of plastic flow at small slip amplitudes and by abrasive wear in the entire contact area at high slip amplitudes.

  • PDF

수증기 유량제어에 따른 피치계 활성탄소섬유 비표면적 특성에 대한 연구 (Study on the Manufacture and Characteristics of Pitch-Based Activated Carbon Fibers Using Steam Activation)

  • 신해름;여승준;노우승;김만태
    • 한국산업융합학회 논문집
    • /
    • 제26권6_3호
    • /
    • pp.1333-1339
    • /
    • 2023
  • To produce activated carbon fibers, the process is carried out through either physical activation method or chemical activation method. In this study, we present the results regarding the characteristics of activated carbon fibers manufactured under various conditions through the quantitative control of steam. The yield after activation indicates a decreasing trend with the increase in steam quantity and activation time. Additionally, specific surface area characteristics exhibit variations based on activation time and steam flow rate. The SEM analysis results reveal that higher steam flow rates lead to the presence of both mesopores and macropores on the surface of activated carbon fibers (ACF).

Development and performance evaluation of a cryogenic blower for HTS magnets

  • Kwon, Yonghyun;Mun, Jeongmin;Lee, Jaehwan;Seo, Geonghang;Kim, Dongmin;Lee, Changhyeong;Sim, Kideok;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.57-61
    • /
    • 2020
  • Cooling by gas helium circulation can be used for various HTS (high temperature superconductor) magnets operating at 20~40 K, and a cryogenic blower is an essential device for circulating gas helium in the cooling system. The performance of the cryogenic blower is determined by various design parameters such as the impeller diameter, the blade number, the vane angle, the volute cross-sectional area, and the rotating speed. The trailing edge angle and the height of impeller vane are also key design factors in determining the blower performance. This study describes the design, fabrication and performance evaluation of cryogenic blower to produce a flow rate of 30 g/s at 5 bar, 35 K gas helium. The impeller shape is designed using a specific speed/specific diameter diagram and CFD analysis. After the fabrication of the cryogenic blower, a test equipment is also developed using a GM cryocooler. The measured flow rates and the pressure differences are compared with the design values at various rotating speeds and the results show a good agreement. Isentropic efficiency is also evaluated using the measured pressures and temperatures.

AlN 분말합성에 있어서 LiF와 BaF$_2$ 첨가효과 (Effect of LiF and BaF2 Addition on Synthesis of AlN Powder)

  • 최병현;이창송;신태수;이종민
    • 한국세라믹학회지
    • /
    • 제28권8호
    • /
    • pp.647-653
    • /
    • 1991
  • In order to synthesize fine AlN powder by the direct nitridation of Aluminum metal power added LiF and BaF2 as additives was heated at 150$0^{\circ}C$ for 3 hrs. in nitrogen gas with flow rate of 20 mι/sec. Additives are promoted the nitridation by prevented the aggromerate of powders when 3% LiF and 2% BaF2 were added to Al metal powder. Rate of nitridation was about 100% and average size of AlN powders were very fine such as 0.3 ${\mu}{\textrm}{m}$. Specific surface area of synthesized AlN powder was 3.95$m^2$/g and also O2 and N2 contents were 2.595% and 33.25%, respectively.

  • PDF

양이온 함침 활성탄에서의 저농도 이산화탄소 상온 흡착특성 (Ambient Adsorption of Low-level Carbon Dioxide by Metal Treated Activated Carbon)

  • 이경미;조영민
    • 한국대기환경학회지
    • /
    • 제25권4호
    • /
    • pp.316-324
    • /
    • 2009
  • Carbon based sorbents for $CO_2$ adsorption were prepared by impregnation with alkali metals ($Li^+$, $K^+$) and alkaline earth metals ($Ca^{2+}$, $Mg^{2+}$). BET surface area of test sorbents was lower than the intrinsic activated carbon. In particular, impregnation of $Ca^{2+}$ or $Mg^{2+}$ resulted in lower surface area of specific adsorption sites than that of $Li^+$ or $K^+$. While the adsorption capacity for $CO_2$ was high in the sorbents containing $Ca^{2+}$ and $Mg^{2+}$, strong interaction with $CO_2$ would cause to drop the capacity after regeneration. The adsorption was found high relatively in the flow with a high concentration of $CO_2$ and in a low flow rate. The adsorption isotherm for the present modified AC sorbents fits well with the Freundlich model.

가속 드라이아이스 snow impact에 의한 도막 제거속도의 측정 (Measurement of Coating Removal Rate of Accelerated Dry Ice Snow Impact)

  • 나영민;김호태;김선근
    • 청정기술
    • /
    • 제10권4호
    • /
    • pp.177-187
    • /
    • 2004
  • 드라이아이스 스노우 젯(dry ice snow jet)을 액체 이산화탄소의 고압팽창에 의해 만들고 운반기체에 의해 더욱 가속시킬 수 있었다. 코팅의 제거기구는 표면 오염입자의 그것과 크게 다르지 않았다. 코팅의 제거를 Hutchings 식으로 정량적으로 표현할 수 있었다. 이들 식에 의한 plot에서 얻은 두개의 매개변수로 코팅의 제거 속도와 단위 이산화탄소의 질량에 의해 제거된 비 코팅면적을 예측할 수 있었으며 아울러 실험데이터의 신뢰도와 실험 에러의 보정도 가능하게 되었다. 노즐 기판 거리와 노즐길이를 바꾸었을 때 얻어진 이들 plot이 한점에서 만날 수 있음을 알 수 있었으며 이점이 jet plume을 모음에서 얻어진 scar 반경의 증대효과와 jet를 확산시킴에서 얻어진 scar 반경 증대효과가 균형을 맞추는 데서 얻어진 것으로 판단된다.

  • PDF

기상 활성화법에 의한 대나무 활성탄 제조 (Production of Activated Carbon from Bamboo by Gas Activation Method)

  • 조광주;박영철
    • 에너지공학
    • /
    • 제13권2호
    • /
    • pp.166-172
    • /
    • 2004
  • The activated carbon was produced from Sancheong bamboo by steam and carbon dioxide gas activation methods. The carbonization of raw material was conducted at 90$0^{\circ}C$ and gas activation reactions were conducted with respect to various conditions. -activation temperature 750-90$0^{\circ}C$, the flow rate of steam 0.5-2g-$H_2O$/g-char$.$hr, the flow rate of carbon dioxide 5-30$m\ell$-$CO_2$/g-char-min and activation time 1-5 hr. The prepared activated carbons were measured yield, the adsorption capacity of iodine and methylene blue, BET specific surface area and pore size distribution. The adsorption capacity of iodine (680.5-1526.1 mg/g) and methylene blue (18.3-221.5 mg/g) increased with creasing activation temperature and activation time. The adsorption capacity of iodine and methylene blue increased with the activation gas quantity in the range of 0.5-1.5g-$H_2O$/g-charㆍhr, 5-18.9$m\ell$-Co$_2$/g-charㆍmin. But those decreased over those range due to the pore shrinkage. The steam activation method was superior in efficiency to carbon dioxide activation method.