• 제목/요약/키워드: arcing

검색결과 219건 처리시간 0.031초

Hot Gas Analysis of Circuit Breakers By Combining Partial Characteristic Method with Net Emission Coefficient

  • Park, Sang-Hun;Bae, Chae-Yoon;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권3호
    • /
    • pp.115-121
    • /
    • 2003
  • This paper proposes a radiation model, which considers radiation transport as an important component in hot gas analysis. This radiation model is derived from combining the method of partial characteristics (MPC) with net emission coefficient (NEC), and it covers the drawbacks of existing models. Subsequently, using this proposed model, the arc-flow interaction in an arcing chamber can be efficiently computed. The arc is represented as an energy source term composed of ohmic heating and the radiation transport in the energy conservation equation. Ohmic heating term was computed by the electric field analysis within the conducting plasma region. Radiation transport was calculated by the proposed radiation model. Also, in this paper, radiation models were introduced and applied to the gas circuit breaker (GCB) model. Through simulation results, the efficiency of the proposed model was confirmed.

적응 자동 재폐로 및 고장거리 산정을 위한 새로운 1단자 알고리즘 (A New One Terminal Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation)

  • Zoran Radojevic;Joong-Rin Shin
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.438-445
    • /
    • 2004
  • This paper presents a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and fault distance calculation. Arc voltage amplitude and fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation and real field record are given.

철탑과 매설배관의 이격거리 관련 기준 (Standards of Separation Distance between Tower and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.53-55
    • /
    • 2005
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. The lightning strokes collected by an electric substation or power line tower might cause arcing through the soil to an adjacent gas pipeline. This paper gives the review of the breakdown mechanism and the standards of separation distance between lower and pipelines.

  • PDF

퍼지 논리 적용에 의한 배전계통의 고장 검출 시스템 개발 (Development of a Fuzzy Logic-based Fault Identification System In Distribution System)

  • 김창종;오용택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.737-739
    • /
    • 1996
  • Abnormal conditions and disturbances in distribution system cause an immediate influence to the customers. Conventional detection schemes for the distribution abnormalities have been applied in limited extents mainly because of their low reliability. In this paper, we developed a disturbance identification system which monitors the load level after a transient, checks the harmonic behavior of the load, and finally makes decision on the cause of the disturbance. This system identifies and discriminates overcurrent faults, arcing ground faults, recloser activities, and foreign object or tree contacts. In the implementation of the identification system, we applied fuzzy logic to better represent some variables whose Quantities are expressed only in non-numerical terms.

  • PDF

Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation

  • ;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.79-81
    • /
    • 2003
  • This paper presents development and testing of a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and the fault distance calculation. The arc voltage amplitude and the fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation are given.

  • PDF

단상재폐로 송전선로에 대한 2차 아크 모델링 (Secondary Arc Modeling for Single-Pole Switching on Transmission Lines)

  • 박병철;이욱화;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.157-159
    • /
    • 1996
  • The secondary arcing phenomenon can be hardly modeled for computer simulation due to its particularly nonlinear characteristics. This paper describes a new computer modeling technique for the secondary arc which can be implemented with the EMTDC. The computer model proposed is based on realistic are conduction behaviors through both FIT and variable resistor modules which is supported in the EMTDC. Simulation results using the proposed technique are compared with some previous studies.

  • PDF

Control Algorithm of Thyristor Rectifier to Improve Arc Stability in DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.371-372
    • /
    • 2012
  • In this paper fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. Based on the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Fixture를 이용한 토양 절연파괴 실험 (Soil Breakdown Test using Fixture)

  • 이현구;하태현;정동학;하윤철;김대경;배정효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

HTV 실리콘 고무에서 열화인자에 따른 저분자량 성분과 표면 발수성의 변화 (Effects of Ageing Factors on Low Molecular Weight Silicone Fluids Content Fluids Content and Surface Hydrophobicity in HTV Silicone Rubber)

  • 허창수;연복희;조한구
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 1999
  • In this paper, we have investigated the effects of the environmental factors on Low Molecular Weight (LMW) silicone fluid contents existing in high temperature vulcanized (HTV) silicone rubber sample, using dipping method and contact angle, current measurement. Artificial treatments such as immersion in water, elevated temperature, UV irradiation and dry band arcing under salt-fog condition are selected as the environmental factors. This results will be helpful to investigate the degradation with time and to expect a life time, because the LMW silicone content, which is important to recovery the hydrophobicity of silicone rubber surface, show different results by each environmental factors.

  • PDF

CD 스터드 용접의 해석 및 결함 분석 Part 2 : 기공 제어

  • 오현석;유중돈
    • Journal of Welding and Joining
    • /
    • 제24권3호
    • /
    • pp.42-48
    • /
    • 2006
  • Since the voids occur at the CD stud welds, the mechanism of void formation and void reduction method are investigated in this work. It is speculated that the voids are formed because of high short-circuit current above 1000A. When the simple flow model is used to estimate the void trapping condition, the most voids are trapped at the weld mainly due to fast cooling rate of the CD stud weld. Since it is almost impossible to remove the voids completely, a method is proposed to reduce the void by decreasing the short-circuit current at the end of the arcing time. The experimental results show that the void is reduced by decreasing the short-circuit current to 1000A.