• Title/Summary/Keyword: architectural damage

Search Result 511, Processing Time 0.025 seconds

Evaluation of Pull-Out Strength of Connections with Roof Cladding using Honey Comb Panel Secured Cool Roof Performance (Cool Roof 성능을 확보한 Honey Comb Panel 지붕 접합부의 인발 성능 평가)

  • Lee, In Ho;Park, Sang Woo;Ko, Kwang Il;Chung, Mi Ja;Lee, Eun Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.139-149
    • /
    • 2016
  • Roof cladding of buildings are required for the measures about the 'screw pull-out' which causes the casualties and the property damage by typhoons. In this study, the pull-out resistance was increased by increasing the penetration depth of the screw installing a ironware called 'insert nut' on the roof cladding frame. Tensile tests were conducted to compare the pull-out strengths of a general screw-joint and a nut insert joint. Roof cladding that is actually being used in the field was produced using the 'solid work' and then the roof claddings using a general screw-joint and a nut insert joint were compared by a static test and dynamic test.

Evaluation on the Impact Resistant Performance of Fiber Reinforced Concrete by High-Velocity Projectile and Contacted Explosion (고속비상체 충돌 및 접촉폭발에 의한 섬유보강 콘크리트의 내충격 성능 평가)

  • Nam, Jeong-Soo;Kim, Hong-Seop;Lee, In-Cheol;Miyauchi, Hiroyuki;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.107-114
    • /
    • 2013
  • In this study we experimentally evaluated an impact resistant performance of fiber reinforced concrete in the moment of explosion by high-velocity projectile with emulsion explosive. To assess the impact resistance, we conducted the impact test of high-velocity projectile which reaches an impact speed of 350 m/s and the experiment of contact exploding emulsion explosive. As a result, bending and tensile performance depending on type of PVA, PE fiber (polyvinyl alcohol fiber, polyethylene fiber) and steel fiber affects destruction of rear side in the form of spalling. Destroying the backside of the concrete compressive strength compared to suppress the bending and tensile performance is affected. In addition, the experiment shows that the destruction patterns of concrete specimen producted by high velocity impact and contact explosion are significantly similar. Therefore, it is possible to predict the destruction patterns of specimens in the situation of contact explosion by high-velocity projectile.

Experimental study on replaceable precast concrete beam-column connections

  • Seung-Ho Choi;Sang-Hoon Lee;Jae-Hyun Kim;Inwook Heo;Hoseong Jeong;Kang Su Kim
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2024
  • The purpose of this study was to develop a system capable of restoring the seismic performance of a precast concrete (PC) connection damaged by an earthquake. The developed PC connection consists of a top-and-seat angle, post-tensioning (PT) tendons, and U-shaped steel. The PC beam can be replaced by cutting the PT tendons in the event of damage. In addition, the seismic performance of the developed PC beam-column connection was evaluated experimentally. A PC beam-column connection specimen was fabricated, and a quasistatic cyclic loading test was conducted to a maximum drift ratio of 2.3%. Subsequently, the PC beam was replaced by a new PC beam, and the repaired PC connection was loaded to a maximum drift ratio of 5.1%. The structural performance of the repaired PC connection was then compared with that of the original PC connection. The difference in the load at the drift ratio of 2.3% between the original and the repaired PC specimens was only 0.2%. The residual drift ratio in the repaired PC specimen did not exceed 1.0% at the 2.0 % drift ratio cycles, which satisfies the life safety performance level specified in ACI 374.2R-13. When the developed PC connection system is used, structural performance can be restored by rapidly replacing the damaged elements.

Evaluation and Improvement of Deformation Capacities of Shear Walls Using Displacement-Based Seismic Design

  • Oh, Young-Hun;Han, Sang-Whan;Choi, Yeoh-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.55-61
    • /
    • 2006
  • RC shear walls are frequently used as lateral force-resisting system in building construction because they have sufficient stiffness and strength against damage and collapse. If RC shear walls are properly designed and proportioned, these walls can also behave as ductile flexural members like cantilevered beams. To achieve this goal, the designer should provide adequate strength and deformation capacity of shear walls corresponding to the anticipated deformation level. In this study, the level of demands for deformation of shear walls was investigated using a displacement-based design approach. Also, deformation capacities of shear walls are evaluated through laboratory tests of shear walls with specific transverse confinement widely used in Korea. Four full-scale wall specimens with different wall boundary details and cross-sections were constructed for the experiment. The displacement-based design approach could be used to determine the deformation demands and capacities depending on the aspect ratio, ratio of wall area to floor plan area, flexural reinforcement ratio, and axial load ratio. Also, the specific boundary detailing for shear wall can be applied to enhance the deformation capacity of the shear wall.

Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment (청감실험을 이용한 건축설비소음의 등급화)

  • You, Hee-Jong;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

Calibration Methodology for Predicting Hysteretic Behavior of Reinforced Concrete Columns Failed in Shear (전단파괴가 발생한 기둥의 이력거동 예측을 위한 매개변수 결정방법 제안)

  • Lee, Chang seok;Han, Sang Whan;Ko, Girbo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2017
  • Columns in existing reinforced concrete structures that are designed and constructed without considering seismic loads generally exhibit widely spaced transverse reinforcements without using seismic hooks. Due to the insufficient reinforcement details in columns compared to the reinforcement requirements specified in modern seismic codes, brittle shear failure is likely to occur. This may lead to sudden collapse of entire structure during earthquakes. Adequate retrofit strategy is required for these columns to avoid such catastrophic event. In order to do so, behavior of columns in existing reinforced concrete structures should be accurately predicted through computational analysis. In this study, an analytical model is proposed for accurately simulating the cyclic behavior of shear critical columns. The parameters for backbone, as well as pinching and cyclic deterioration in strength and stiffness are calibrated using test data of column specimens failed by shear.

Maintenance Model of Agricultural Facilities Using CBR

  • Kim, Jae-Yeob;Lee, Yong-Kyu;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.2
    • /
    • pp.133-141
    • /
    • 2012
  • As we move from the industrial age to the information age, domestic industries are changing rapidly, and rural society is also laying the foundation to make use of information technologies. Through this kind of modernization, the size of agricultural facilities has been increasing on a significant scale. But, in reality, there are many difficulties in the maintenance of agricultural facilities in proportion to their growing number. Accordingly, this research aims to solve the fundamental problems that occur with agricultural facilities in the maintenance stage. In addition, it aims to provide information on how to maintain and manage facilities for farmers. The presentation of the maintenance information was conducted using a case-based reasoning method that solves current problems based on past cases. The tool of case-based reasoning was applied to define the establishment of the base for cases, characteristic variables and maintenance measures. The effectiveness of a CBR model was examined through the case study. The use of the case-based reasoning method is judged to be effective as a tool to support the decisions of farmers regarding maintenance. When the maintenance measures derived through the CBR model are offered to farmers, the fundamental problems of maintaining agricultural facilities will be solved, and the damage to such facilities minimized.

Investigation on Effective Peak Ground Accelerations Based on the Gyeongju Earthquake Records (경주지진 관측자료에 기반한 유효최대지반가속도 분석)

  • Shin, Dong Hyeon;Hong, Suk-Jae;Kim, Hyung-Joon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.425-434
    • /
    • 2016
  • This study investigates important parameters used to determine an effective peak ground acceleration (EPGA) based on the characteristics of response spectra of historical earthquakes occurred at Korean peninsula. EPGAs are very important since they are implemented in the Korean Building Code for the seismic design of new structures. Recently, the Gyeongju earthquakes with the largest magnitude in earthquakes measured at Korea took place and resulted in non-structural and structural damage, which their EPGAs should need to be evaluated. This paper first describes the basic concepts on EPGAs and the EPGAs of the Gyeongju earthquakes are then evaluated and compared according to epicentral distances, site classes and directions of seismic waves. The EPGAs are dependant on normalizing factors and ranges of period on response spectrum constructed with the Gyeongju earthquake records. Using the normalizing factors and the ranges of period determined based on the characteristics of domestic response spectra, this paper draw a conclusion that the EPGAs are estimated to be about 30 % of the measured peak ground accelerations (PGA).

Dynamic Behavior Characteristics of Three-Story Stone Pagoda at Cheollongsa Temple Site by Earthquake (지진에 의한 천룡사지 삼층석탑의 동적거동 특성)

  • Kim, Ho Soo;Kim, Dong Kwan;Jeon, Geon Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.305-314
    • /
    • 2021
  • The Gyeongju and Pohang earthquakes caused damages to many cultural properties; particularly, stone pagoda structures were significantly damaged among masonry cultural properties. To preserve these structures, it is necessary to understand their dynamic behavior characteristics under earthquakes. Analyses on such areas as deformation, frequency, maximum acceleration, permanent displacement, sliding, and rocking have to be performed. Although many analytical studies have already been conducted, dynamic behavior studies based on experiments are insufficient. Therefore, this study analyzed dynamic behavior characteristics by performing a shaking table experiment on a three-story stone pagoda structure at the Cheollongsa temple site damaged by the Gyeongju earthquake. As a result of the experiment, the displacements of stylobates did not occur significantly, but the tower body parts rotated. In particular, the rotation of the 1F main body stone was relatively larger than that of the other chief body stones because the 1F main body stone is relatively more slender than the other parts. In addition, the decorative top was identified as the component most vulnerable to sliding. This study found that the 1F main body stone is vulnerable to rocking, and the parts located on the upper part are more vulnerable to sliding.

A Study on the Post-buckling Behaviour of Single-layer Domes exposed to Fire (화재에 노출된 단층 돔의 후좌굴 거동에 관한 연구)

  • Lee, Sang-Jin;Bae, Jungeun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.139-148
    • /
    • 2019
  • The lightweight structures such as domes are particularly vulnerable when it has been subjected to high temperature induced by the fire. It is therefore crucial to predict the possible instability path of structures exposed to the fire in structural design process. In this study, the instabilities of single-layer domes is investigated by using finite element technologies with the consideration of high temperature. The material properties of members under high temperature are considered by using the reduction factors which is provided in Eurocodes 3. Some damage patterns are assumed with use of a structural unit which is symmetric in radial direction. For numerical evaluations, the geometrically nonlinear truss element is implemented and the arch-length control method is employed to trace the post-buckling behaviour of domes. From numerical results, it is found to be that a significant change of post-buckling behaviour is detected in dome structures when structural members are exposed to the fire.