Abstract
Roof cladding of buildings are required for the measures about the 'screw pull-out' which causes the casualties and the property damage by typhoons. In this study, the pull-out resistance was increased by increasing the penetration depth of the screw installing a ironware called 'insert nut' on the roof cladding frame. Tensile tests were conducted to compare the pull-out strengths of a general screw-joint and a nut insert joint. Roof cladding that is actually being used in the field was produced using the 'solid work' and then the roof claddings using a general screw-joint and a nut insert joint were compared by a static test and dynamic test.
Keywords
Pull-Out; Screw; Nut Insert; Roof cladding; Static test; Dynamic test;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김옥(2010) Cool Roof 시스템의 성능기준 및 설계지침에 관한 연구, 박사학위논문, 중앙대학교. Kim, O. (2010) A Study on The Performance Standards and Design Guidelines of Cool Roof System, Ph. D. Dissertation, University of Chung-Ang, (in Korean).
2 대한건축학회(2009) 건축구조기준 및 해설, 풍하중, pp.85-121. Architectural Institute of Korea (2009) Korean Building Code 2009. WindLoad, pp.85-121.
3 Kim, P., Henderson, D., and Ginger, J. (2007) LHL:New Australian test method for wind induced fatigue of building envelopes. James Cook University, Australia. ICWE12.
4 최영현 (2001) 냉간성형 형강의 접합부에 관한 연구. 영남대학교 석사학위논문. Choi, Y.H. (2001) Study on the connection of cold-formed steel section frames, Master dissertation, Yeungnam University, (in Korean).
5 조종수(2002) 냉간성형 형강 프레임 구조의 거동에 관한 연구. 영남대학교 석사학위논문. Cho, J.S. (2002) Study on the behavior of Cold-formed steel section frames, Master dissertation, Yeungnam University, (in Korean).
6 윤상훈(2003) 신형상 PRY-TRUSS의 접합부 거동에 관한 연구. 영남대학교 석사학위논문. Yoon, S.H. (2003) A Study on The Connections of PRY-Truss Steel Sections, Master Dissertation, Yeungnam University, (in Korean).
7 강승원(2003) 신형상 냉간성형 경량형강 프레임의 구조적 거동. 영남대학교 석사학위논문. Kang, S.W. (2003) The structural behavior of cold-formed steel section frames, Master dissertation, Yeungnam University, (in Korean).
8 이화형, 김관의(2002) 국산 대나무 OSB의 못 및 나사못 인발저항, 한국가구학회논문집, 한국가구학회, 제13권, 제3호, pp.2-6. Lee, H.H. and Kim, G.E. (2002) Nail & Screw Withdrawal Resistance of OSB Made from Domestic Bamboo, Vol.13, pp.2-6 (in Korean).
9 Xu, Y. (1995) Fatigue Performance of Screw-Fastened Light-Gauge-Steel Roofing Sheets. Journal of Structural Engineering, ASCE, Vol.121, No.3, pp.389-398.   DOI
10 Research report (2009) Screw Connections Subject to Tension Pull-Out and Shear Forces, AISI, Fall, viii pp.53, (in USA).