• 제목/요약/키워드: architectural condition

검색결과 766건 처리시간 0.022초

전문가 인식조사를 통한 녹색건축물 교육 실태분석과 개선방안 연구 (The Current Status Analysis and Improvement of Green Building Education through Expert Survey)

  • 김용국;송유미;조영진
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.49-57
    • /
    • 2018
  • The purpose of this study is to analyze the current condition of green building education, which is a necessary condition to activate green architecture, with the need to reduce greenhouse gas emissions in the building sector. The main results are as follows. First, the level of education and the level of domestic green architecture were generally underestimated. Second, in order to increase the satisfaction of participants in green building education, it is necessary to increase the number of courses and to increase the number of lecturers who have excellent practical skills. Third, there is a need to strengthen green building programs related to BEMS and green remodeling. Fourth, it is necessary to expand the education on green architecture for the people in the architectural planning and design field and the related field officials. Fifth, green building education needs to be implemented in conjunction with curriculum of elementary, middle and high school. Sixth, it is necessary to diversify the PR(public relations) channels of the green building education program and to provide a way to give the employment increase point when the curriculum is completed. Seventh, there is a need to expand administrative and financial incentives for green architecture in order to revitalize green architecture education.

다가구 주택 반지하세대의 주거환경 분석 - 장기 온·습도 모니터링 분석을 통한 실측결과를 중심으로 - (Analysis of Housing Environment in Semi Basement Multi-family Housing Units - Focuses on long-term analyzed measurements of temperature and humidity obtained from the housing units -)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.83-90
    • /
    • 2018
  • This study was conducted to investigate the living environment of semi-basement housing units in multi-household houses. It analyzed measurements of temperature and humidity obtained from the housing units. For this study, temperature and humidity sensors were installed in 10 semi-basement housing units to measure interior temperature and humidity for 13 months. A survey was conducted to get information about the occurrence of dew condensation and mildew and to investigate residents' satisfaction level with the residential environment. According to the result, all the housing units under study had dew condensation and mildew. The average summer temperature of the 10 housing units was $27.84^{\circ}C$, and average humidity was 64.91%RH, while the average winter temperature was $20.6^{\circ}C$, and the average humidity was 40.12%RH. Depending on the condition of each housing unit, deviation was big. Residents' average level of satisfaction with the living condition was 2.03 which shows a low satisfaction (on a scale of 1-5 with 5 being completely satisfied.).

SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지 (Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building)

  • 채영태
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

유량변화를 고려한 온수배관의 온도분포 계산법평가에 관한 연구 (A Evaluation of Calculation Method for Temperature Distribution of Hot Water Pipe with Changing Flow Rate)

  • 서승직;최창호
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.53-61
    • /
    • 1999
  • We already presented new calculation method about the temperature distribution in hot water pipe flow of the unsteady condition. In this paper, we introduce consequence of the case study to confirm appropriation of the calculation method, and case study performs to establish actual hot water use supposed two model that is; the CWV(constant water volume) and VWV(variable water volume).

  • PDF

비정상조건하의 온수배관의 온도분포에 관한 수치계산법 연구 (A Calculation Method for Temperature Distribution of Hot Water Pipe under Unsteady Condition)

  • 최창호;서승직
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.13-21
    • /
    • 1999
  • Calculation method about the water temperature variable inside hot water pipe had proposed in the past does not correspond with branch pipe system, variable of water volume, variable of entrance water temperature, using and so on. A calculation method proposed in this paper can solve above problems, and calculate the kinds variation of the water temperature inside pipe in the real use state of the hot water pipe.

  • PDF

과거 건축의 의미와 그 수용 (The Meaning of the Past Architecture and its Acceptance)

  • 임성훈
    • 대한건축학회연합논문집
    • /
    • 제21권2호
    • /
    • pp.113-120
    • /
    • 2019
  • This paper examines the relationship between architecture of the past and architecture of the present, and suggest that necessity to reinterpret it in the context of today's architecture, rather than accepting the past architecture as its historical meaning. Such a condition, however, the architecture of the past works in another ways not in a historical ways that is generally perceived, and this paper suggest another interpretations in the meaning of past architecture and what significance it has.

Geiger형 케이블 돔 구조물의 외력에 따른 동적 불안정 특성 비교분석 (A Comparative Analysis of Dynamic Instability Characteristic of Geiger-Typed Cable Dome Structures by Load Condition)

  • 김승덕;신인아
    • 한국공간구조학회논문집
    • /
    • 제14권1호
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this paper is to study comparative of dynamic instability characteristic of Geiger-typed cable dome structures by load condition, which is well-known among the cable dome structures that are the lightweight hybrid structure using compression and tension element continuously. Dynamic buckling process in the phase plane is very important thing for understanding why unstable phenomena are sensitively originated in nonlinear dynamic by various initial conditions. But there is no paper for the dynamic instability of hybrid cable dome by Sinusoidal Excitations, many papers which deal with the dynamic instability for shell-structures under the step load have been published. As a result of Geiger-typed cable dome, which shows chaotic behavior in dynamic nonlinear analysis with initial imperfection.

Analyzing and Comparing the Effect on Lightsources and Colours in the Residences and Office Interior

  • Jin, Eun-Mi;Kang, Young;Lee, Jin-Sook
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 춘계 학술대회 및 국제 감성공학 심포지움 논문집 Proceeding of the 2000 Spring Conference of KOSES and International Sensibility Ergonomics Symposium
    • /
    • pp.149-156
    • /
    • 2000
  • The aim of this study is to propose the predictive index and analyze the effect of lightsources and colour image types in the residence and office interior.This study was consisted of four steps, and was carried out as follows. 1) The condition of experiment was set up by optical characteristic of lightsources and colours. 2) The scaled model space was manufactured for the evaluation of the same condition by each space. And, some piece of furniture was manufactured for the representation of each space. 3) The emotivity response of lightsources and colours was measured. 4) Results of the evaluation of lightsources and colours were compared and analyzed by conditions, and the predictive index was proposed by image types.

  • PDF

Sensitive analysis of design factor for the optimum design of PVT system

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2015
  • Purpose: Recently, renewable energy system has been widely used to reduce the energy consumption and CO2 emission of building. A photovoltaic/thermal(PVT) system is a kind of efficient energy uses, which is combined with photovoltaic module and solar thermal collector. PVT system removes heat from PV module by through thermal fluid to raise the performance efficiency of the PV system. However, though PVT system has the merit of the improved efficiency in theoretical approach, there have been few performance analysis for PVT system using the dynamic energy simulation. In this study, in order to establish the optimum design method of this system, simulation was conducted by using individual system modules. Method: For the dynamic simulation, TRNSYS17 was used and local weather data was utilized. Furthermore, the system performance in various installation condition was calculated by case studies. Result: As a result, the amount of electric generation and heat production in each case was found by the simulation. The gap of system performance was also evident according to the installation condition.

A Daylight Calculation Method for a Louver System Under the Uniform Sky Condition

  • Kim, Kang-Soo;Hwang, Young-Seok
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.41-46
    • /
    • 1999
  • The configuration factors in the flux transfer method are applied to calculate daylight factors reaching a station point. To analyze the window equipped with a louver system, geometrical correlation is used for the length shielded by the louver. The space in front of a window is assumed to be an imaginary outdoor space for calculating the luminance of the louver system. The data calculated from this study are compared with SUPERLlTE simulation data and the scale model data. Scale model data are collected on the roof of the Engineering building at Korea University in Seoul under the uniform sky condition.

  • PDF