• Title/Summary/Keyword: application time

Search Result 14,931, Processing Time 0.048 seconds

Anti-Windup Starting-Time Control Strategy for a First-Order-Plus-Dead-Time Model and Application of Extruder Temperature Control

  • Onogaki, Hitoshi;Yokoyama, Shuichi;Hamane, Hiroto;Kanouya, Kazuyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.70.4-70
    • /
    • 2002
  • $\textbullet$ Introduction $\textbullet$ PID Control and Two-Degree-Of-Freedom Control $\textbullet$ Switching Actuating Value By the 100% Actuating Value $\textbullet$ Application of Extruder Temperature Control $\textbullet$ Conclusion

  • PDF

Study on the Application Limits and Sensitivity Analysis for the Parameters of Time of Concentration (도달시간 산정공식의 입력변수 적용범위 및 민감도 분석)

  • 김선주;강상진;이광야;박재흥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.6
    • /
    • pp.72-82
    • /
    • 2000
  • Many lot of books introduce the methods to calculate the time of concentration, and these are described as various forms of formulas. There are few formulas appropriate for our basin characteristics Therefone, there are problems to make excessive or less estimation when these formulas are used. To solve these problems, comparison of formulas and sensitivity analysis for them were made with converting parameters. Finally, Time of concentration was estimated to derive Application limits for 3 watersheds by standardized formulas. In the case of input parameters analysis, SCS formula has the highest value by the length, Kerby by the height and SCS by the slope, respectively, while Kraven formula has the lowest value among them. Concerning the relative sensitivity by Taylor series, the time of concentration showed the constant effect while increasing of the length and slope, and the length was more sensitive than the slope in parameters. Finally the standardization formula developed in this study was applied to derive application limits for 3 watersheds(total 17 subbasins). In this case, Rziha(8 subbasins) and SCS(9 subbasins) formulas were the most similar to observed data of total 17 subbasins respectively. Application limits were about 300~500$\textrm{km}^2$ area, 30~60km length and under 0.01 slope for Rziha formula and about 100~200$\textrm{km}^2$ area, 10~30km length, and over 0.01 slope for SCS formula, respectively.

  • PDF

Development and Validation of a Postpartum Care Mobile Application for First-time Mothers (초산모를 위한 산후관리 모바일 앱 개발 및 효과 검증)

  • Lee, Ju Yeon;Kim, Hye Young
    • Women's Health Nursing
    • /
    • v.23 no.3
    • /
    • pp.210-220
    • /
    • 2017
  • Purpose: The aims of the study were to develop mobile application for postpartum care of first-time mothers and to validate it's effect. Methods: Using a nonequivalent control group pretest-posttest design, 52 first-time mothers were recruited (26 each in experimental and control) and the experimental group used the mobile application for 6 weeks after delivery. Postpartum self-care knowledge and confidence, infant care knowledge and confidence, and postpartum depressive mood (Edinburgh Postnatal Depression Scale) were measured before discharge from the hospital and 6 weeks later. Results: Women who have used the postpartum care mobile application reported higher levels of postpartum self-care knowledge (p=.030) and confidence (p=.023) infant care knowledge (p=.001) and confidence (p=.004), while scores of postpartum depression (p=.021) were lower than those in the control group. Conclusion: The postpartum-care mobile application developed in this research may be effective in reinforcing knowledge and confidence for postpartum self-care and infant care and in reducing postpartum depressive mood.

Hybrid Multi-System-on-Chip Architecture as a Rapid Development Approach for a High-Flexibility System

  • Putra, Rachmad Vidya Wicaksana;Adiono, Trio
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • In this paper, we propose a hybrid multi.system-on-chip (H-MSoC) architecture that provides a high-flexibility system in a rapid development time. The H-MSoC approach provides a flexible system-on-chip (SoC) architecture that is easy to configure for physical- and application-layer development. The physical- and application-layer aspects are dynamically designed and modified; hence, it is important to consider a design methodology that supports rapid SoC development. Physical layer development refers to intellectual property cores or other modular hardware (HW) development, while application layer development refers to user interface or application software (SW) development. H-MSoC is built from multi-SoC architectures in which each SoC is localized and specified based on its development focus, either physical or application (hybrid). Physical HW development SoC is referred to as physical-SoC (Phy-SoC) and application SW development SoC is referred to as application-SoC (App-SoC). Phy-SoC and App-SoC are connected to each other via Ethernet. Ethernet was chosen because of its flexibility, high speed, and easy configuration. For prototyping, we used a LEON3 SoC as the Phy-SoC and a ZYNQ-7000 SoC as the App-SoC. The proposed design was proven in real-time tests and achieved good performance.

A Study on the Clinical Application of Five-Transport-Points in Huangdineijing - Focused on Frequency of Application and Selection (황제내경의 오수혈 임상 활용 연구 - 사용 빈도와 선혈을 중심으로)

  • Kim, Do-Hoon;Baik, Yousang
    • Korean Journal of Acupuncture
    • /
    • v.37 no.4
    • /
    • pp.276-283
    • /
    • 2020
  • Objectives : In each section of Huangdineijing, we reviewed how the actual clinical application of Five-Transport-points was reflected and looked at the pattern of the application at the time. Methods : The contents related to Five-Transport-points in Huangdineijing were collected from each part, and analyzed. Results : There was a great difference in the number and contents of the clinical application of each Five-Transport-point for each 12 meridian, and only 28.3% of all Five-Transport-points had been related to clinical treatment. In addition, in specific applications, spring point, stream point, and sea point were used more often than well point, and Five-Transport-points between the same meridian or different meridians were used in combination as needed. Conclusions : Five-Transport-points described in Huangdineijing are intended to be operated within the overall framework structurally or functionally with a certain principle, but as a result of comprehensive analysis of specific examples of clinical application, there was a difference in the application between Five-Transport-points. This indicates that at the time of the establishment of Huangdineijing, which was the early stage of the development of Traditional East Asian Medicine, a variety of miscellaneous acupuncture methodologies were used in addition to those based on five elements principle.

A Study on the Effect of Waiting Time factor of Hospitals on Customer Satisfaction and Service Values (의료서비스의 대기시간 요인이 고객만족과 서비스 가치에 미치는 영향)

  • Kim, Il-Kwon;Kwon, Chang-Ik;Yang, Jong-Hyun;Chang, Dong-Min
    • Korea Journal of Hospital Management
    • /
    • v.15 no.3
    • /
    • pp.47-68
    • /
    • 2010
  • One of the important complaint factors by the patients using medical institutions is various kinds of waiting time. This research is about the causal relationships among waiting time(application of waiting time, perceived of waiting time, fairness of waiting, explanation of the delay, acceptance possibility), service values, and customer satisfaction. The subjects for this study were 256 out-patients currently using seven general hospitals in the Busan area. The findings of the empirical analysis are as follows: First, the good application of waiting time or fair waiting time procedure didn't actually affect perceived waiting time. Second, though the application of waiting time didn't affect acceptance possibility, the fair procedure of waiting time had an affirmative effect on acceptance possibility. Third, even when there was enough explanation about the need to wait, it could shorten perceived waiting time but failed to get sufficient sympathy or agreement from the patients. Fourth, the possibility of acceptance following the sufficient sympathy of patients had an effect on shortening perceived waiting time. Fifth, perceived waiting time lowered customer satisfaction, but had no negative effect on service values. Finally, the ranges of acceptance possibility by the patients were found to increase customer satisfaction and maximize service values. In conclusion, every medical institution needs to focus on, first of all, shortening waiting time for more customer satisfaction and improved service values.

  • PDF

Real-time transmission properties of industrial switched Ethernet with cascade structure (다계층 구조를 가진 산업용 스위치드 이더넷에서의 실시간 전송 특성)

  • Lee, Kyung-Chang;Lee, Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.718-725
    • /
    • 2004
  • The real-time industrial network, often referred to as fieldbus, is an important element for intelligent manufacturing systems. Thus, in order to satisfy the real-time requirements of field devices, numerous fieldbus protocols have been announced. But, the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. Therefore, as an alternative to fieldbus, the computer network technology, especially Ethernet (IEEE 802.3), is being adapted to the industrial environment. However, the crucial technical obstacle for Ethernet is its non-deterministic behavior that makes it inadequate for industrial applications where real-time data have to be delivered within a certain time limit. Recently, the development of switched Ethernet shows a very promising prospect for industrial application due to the elimination of uncertainties in the network operation resulting in much improved performance. This paper focuses on the application of the switched Ethernet with cascade structure for industrial communications. More specifically, this paper presents an analytical performance evaluation of switched Ethernet with cascade structure, and a case study about networked control system.

Face Recognition System for Multimedia Application (멀티미디어 응용을 위한 얼굴 인식시스템)

  • Park, Sang-Gyou;Seong, Hyeon-Kyeong;Han, Young-Hwan
    • Journal of IKEEE
    • /
    • v.6 no.2 s.11
    • /
    • pp.152-160
    • /
    • 2002
  • This paper is the realization of the face recognition system for multimedia application. This system is focused on the design concerning the improvement of recognition rate and the reduction of processing time for face recognition. The non-modificated application of typical RGB color system enables the reduction of time required for color system transform. The neural network and the application of algorithm using face characteristic improves the recognition rate. After mosaicking an image, a face-color block has been selected through the color analysis of mosaic block. The characteristic of the face removes the mis-checked face-color candidate block. Finally, from the face color block, four special values are obtained. These values are processed to the neural network using the back propagation algorithm. The output values are the touchstone to decide the genuineness of face field. The realized system showed 90% of face recognition rate with less than 0.1 second of processing time. This result can be understood as sufficient processing time and recognition rate to find out the face block for multimedia application in dynamic image.

  • PDF

Effect of different chlorhexidine application times on microtensile bond strength to dentin in Class I cavities

  • Kang, Hyun-Jung;Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • Objectives: This study evaluated the effect of 2% chlorhexidine digluconate (CHX) with different application times on microtensile bonds strength (MTBS) to dentin in class I cavities and intended to search for ideal application time for a simplified bonding protocol. Materials and Methods: Flat dentinal surfaces with class I cavities ($4mm{\times}4mm{\times}2mm$) in 40 molar teeth were bonded with etch-and-rinse adhesive system, Adper Single Bond 2 (3M ESPE) after: (1) etching only as a control group; (2) etching + CHX 5 sec + rinsing; (3) etching + CHX 15 sec + rinsing; (4) etching + CHX 30 sec + rinsing; and (5) etching + CHX 60 sec + rinsing. Resin composite was builtup with Z-250 (3M ESPE) using a bulk method and polymerized for 40 sec. For each condition, half of the specimens were immediately submitted to MTBS test and the rest of them were assigned to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using two-way ANOVA, at a significance level of 95%. Results: There was no significant difference in bond strength between CHX pretreated group and control group at the immediate testing period. After thermocycling, all groups showed reduced bond strength irrespective of the CHX use. However, groups treated with CHX maintained significantly higher MTBS than control group (p < 0.05). In addition, CHX application time did not have any significant influence on the bond strength among groups treated with CHX. Conclusion: Application of 2% CHX for a short time period (5 sec) after etching with 37% phosphoric acid may be sufficient to preserve dentin bond strength.

Remineralization effect of casein phosphopeptide-amorphous calcium fluoride phosphate on the tooth enamel according to the etching time and frequency of application (산부식 시간과 도포 횟수에 따른 불화 카제인포스포펩타이드-아모르포우스칼슘포스페이트의 치아 법랑질 재광화 효과)

  • Jung, Su-Jin;Lee, Mi-Ra
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5602-5609
    • /
    • 2014
  • This study examined the remineralization effect of CPP-ACFP according to the etching time and the frequency of application. A CPP-ACFP paste was formed from a combination of CPP-ACP paste and fluorine. The remineralization effect of CPP-ACFP was measured according to the etching time and the frequency of applications of CPP-ACFP. The microhardness of 64 teeth was measured as the sound sample and observed by scanning electron microscopy. As a result, the effect on remineralization of the enamel increased with increasing etching time and frequency of application. Therefore, a CPP-ACP paste combination to fluorine in the tooth mineral CPP-ACFP paste fluoride application can be supplied with the material-advisable enamel remineralization.