• Title/Summary/Keyword: application program

Search Result 5,141, Processing Time 0.036 seconds

A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash (Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구)

  • Yang, Gwang-Gil;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: The various studies and efforts to develop program are in progress in the field of nuclear medicine for the purpose of reducing scan time. The Oncoflash is one of the programs used in whole body bone scan which allows to maintain the image quality while to reduce scan time. When Those applications are used in clinical setting, both the image quality and reduction of scan time should be considered, therefore, the purpose of this study was to determine the criteria for proper scan speed. Materials and Methods: The subjects of this study were the patients who underwent whole body bone scan at the departments of nuclear medicine in the Asan Medical Center located in Seoul from 1st to 10th, July, 2008. The whole body bone images obtained in the scan speed of 30cm/min were classified by the total counts into under 800 K, and over 800 K, 900 K, 1,000 K, 1,500 K, and 2,000 K. The image quality were assessed qualitatively and the percentages of those of 1,000K and under of total counts were calculated. The FWHM before and after applying the Oncoflash were analyzed using images obtained in $^{99m}Tc$ Flood and 4-Quadrant bar phantom in order to compare the resolution according to the amount of total counts by the application of the Oncoflash. Considering the counts of the whole body bone scan, the dosed 2~5 mCi were used. 152 patients underwent the measurement in which the counts of Patient Postioning Monitor (PPM) were measured with including head and the parts of chest which the starting point of whole body bone scan from 7th to 26th, August, 2008. The correlations with total counts obtained in the scan speed of 30cm/min among them were analyzed (The exclusion criteria were after over six hours of applying isotopes or low amount of doses). Results: The percentage of the whole body bone image which has the geometric average of total counts of under 1,000K among them obtained in the scan speed of 30cm/min were 17.6%(n=58) of 329 patients. The qualitative analysis of the image groups according to the whole body counts showed that the images of under 1,000K were assessed to have coarse particles and increased noises. The analysis on the FWHM of the images before and after applying the Oncoflash showed that, in the case of PPM counts of under 3.6 K, FWHM values after applying the Oncoflash were higher than that before applying the Oncoflash, whereas, in the case of that of over 3.6 K, the FWHM after applying the Oncoflash were not higher than that before applying the Oncoflash. The average of total counts at 2.5~3.0 K, 3.1~3.5 K, 3.6~4.0 k, 4.1~4.5 K, 4.6~5.0 K, 5.1~6.0 K, 6.1~7.0 K, and 7.1 K over (in PPM) were $965{\pm}173\;K$, $1084{\pm}154\;K$, $1242{\pm}186\;K$, $1359{\pm}170\;K$, $1405{\pm}184\;K$, $1640{\pm}376\;K$, $1,771{\pm}324\;K$, and $1,972{\pm}385\;K$, respectively and the correlations between the counts in PPM and the total counts of image obtained in the scan speed of 30 cm/min demonstrated strong correlation (r=.775, p<.01). Conclusions: In the case of PPM coefficient over 3.6 K, the image quality obtained in the scan speed of 30cm/min and after applying the Oncoflash was similar to that obtained in the scan speed of 15 cm/min. In the case of total counts over 1,000 K, it is expected to reduce scan time without any damage on the image quality. In the case of total counts under 1,000 K, however, the image quality were decreased even though the Oncoflash is applied, so it is recommended to perform the re-image in the scan speed of 15 cm/min.

  • PDF

Study of Patient Teaching in The Clinical Area (간호원의 환자교육 활동에 관한 연구)

  • 강규숙
    • Journal of Korean Academy of Nursing
    • /
    • v.2 no.1
    • /
    • pp.3-33
    • /
    • 1971
  • Nursing of today has as one of its objectives the solving of problems related to human needs arising from the demands of a rapidly changing society. This nursing objective, I believe, can he attained by the appropriate application of scientific principles in the giving of comprehensive nursing care. Comprehensive nursing care may be defined as nursing care which meets all of the patient's needs. the needs of patients are said to fall into five broad categories: physical needs, psychological needs, environmental needs, socio-economic needs, and teaching needs. Most people who become ill have adjustment problems related to their new situation. Because patient teaching is one of the most important functions of professional nursing, the success of this teaching may be used as a gauge for evaluating comprehensive nursing care. This represents a challenge foe the future. A questionnaire consisting of 67 items was distributed to 200 professional nurses working ill direct patient care at Yonsei University Medical Center in Seoul, Korea. 160 (80,0%) nurses of the total sample returned completed questionnaires 81 (50.6%) nurses were graduates of 3 fear diploma courser 79 (49.4%) nurses were graduates of 4 year collegiate nursing schools in Korea 141 (88,1%) nurses had under 5 years of clinical experience in a medical center, while 19 (11.9%) nurses had more than 5years of clinical experience. Three hypotheses were tested: 1. “Nurses had high levels of concept and knowledge toward patient teaching”-This was demonstrated by the use of a statistical method, the mean average. 2. “Nurses graduating from collegiate programs and diploma school programs of nursing show differences in concepts and knowledge toward patient teaching”-This was demonstrated by a statistical method, the mean average, although the results showed little difference between the two groups. 3. “Nurses having different amounts of clinical experience showed differences in concepts and knowledge toward patient teaching”-This was demonstrated by the use of a statistical method, the mean average. 2. “Nurses graduating from collegiate programs and diploma school programs of nursing show differences in concepts and knowledge toward patient teaching”-This was demonstrated by a statistical method, the mean average, although the results showed little difference between the two groups. 3. “Nurses having different amounts of clinical experience showed differences in concepts and knowledge toward patient teaching”-This was demonstrated by the use of the T-test. Conclusions of this study are as follow: Before attempting the explanation, of the results, the questionnaire will he explained. The questionnaire contained 67 questions divided into 9 sections. These sections were: concept, content, time, prior preparation, method, purpose, condition, evaluation, and recommendations for patient teaching. 1. The nurse's concept of patient teaching: Most of the nurses had high levels of concepts and knowledge toward patient teaching. Though nursing service was task-centered at the turn of the century, the emphasis today is put on patient-centered nursing. But we find some of the nurses (39.4%) still are task-centered. After, patient teaching, only a few of the nurses (14.4%) checked this as “normal teaching.”It seems therefore that patient teaching is often done unconsciously. Accordingly it would he desirable to have correct concepts and knowledge of teaching taught in schools of nursing. 2. Contents of patient teaching: Most nurses (97.5%) had good information about content of patient teaching. They teach their patients during admission about their diseases, tests, treatments, and before discharge give nurses instruction about simple nursing care, personal hygiene, special diets, rest and sleep, elimination etc. 3. Time of patient teaching: Teaching can be accomplished even if there is no time set aside specifically for it. -a large part of the nurse's teaching can be done while she is giving nursing care. If she believes she has to wait for time free from other activities, she may miss many teaching opportunities. But generally proper time for patient teaching is in the midmorning or midafternoon since one and a half or two hours required. Nurses meet their patients in all stages of health: often tile patient is in a condition in which learning is impossible-pain, mental confusion, debilitation, loss of sensory perception, fear and anxiety-any of these conditions may preclude the possibility of successful teaching. 4. Prior preparation for patient teaching: The teaching aids, nurses use are charts (53.1%), periodicals (23.8%), and books (7.0%) Some of the respondents (28.1%) reported that they had had good preparation for the teaching which they were doing, others (27.5%) reported adequate preparation, and others (43.8%) reported that their preparation for teaching was inadequate. If nurses have advance preparation for normal teaching and are aware of their objectives in teaching patients, they can do effective teaching. 5. Method of patient teaching: The methods of individual patient teaching, the nurses in this study used, were conversation (55.6%) and individual discussion (19.2%) . And the methods of group patient teaching they used were demonstration (42.3%) and lecture (26.2%) They should also he prepared to use pamphlet and simple audio-visual aids for their teaching. 6. Purposes of patient teaching: The purposes of patient teaching is to help the patient recover completely, but the majority of the respondents (40.6%) don't know this. So it is necessary for them to understand correctly the purpose of patient teaching and nursing care. 7. Condition of patient teaching: The majority of respondents (75.0%) reported there were some troubles in teaching uncooperative patients. It would seem that the nurse's leaching would be improved if, in her preparation, she was given a better understanding of the patient and communication skills. The majority of respondents in the total group, felt teaching is their responsibility and they should teach their patient's family as well as the patient. The place for teaching is most often at the patient's bedside (95.6%) but the conference room (3.1%) is also used. It is important that privacy be provided in learning situations with involve personal matters. 8. Evaluation of patient teaching: The majority of respondents (76.3%,) felt leaching is a highly systematic and organized function requiring special preparation in a college or university, they have the idea that teaching is a continuous and ever-present activity of all people throughout their lives. The suggestion mentioned the most frequently for improving preparation was a course in patient teaching included in the basic nursing program. 9. Recommendations: 1) It is recommended, that in clinical nursing, patient teaching be emphasized. 2) It is recommended, that insertive education the concepts and purposes of patient teaching he renewed for all nurses. In addition to this new knowledge, methods and materials which can be applied to patient teaching should be given also. 3) It is recommended, in group patient teaching, we try to embark on team teaching.

  • PDF

A Study on Air Operator Certification and Safety Oversight Audit Program in light of the Convention on International Civil Aviation (시카고협약체계에서의 항공안전평가제도에 관한 연구)

  • Lee, Koo-Hee;Park, Won-Hwa
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.115-157
    • /
    • 2013
  • Some contracting States of the Convention on International Civil Aviation (commonly known as the Chicago Convention) issue FAOC(Foreign AOC and/or Operations Specifications) and conduct various safety audits for the foreign operators. These FAOC and safety audits on the foreign operators are being expanded to other parts of the world. While this trend is the strengthening measure of aviation safety resulting in the reduction of aircraft accident, it is the source of concern from the legal as well as economic perspectives. FAOC of the USA doubly burdens the other contracting States to the Chicago Convention because it is the requirement other than that prescribed by the Chicago Convention of which provisions are faithfully observed by almost all the contracting States. The Chicago Convention in its Article 33 stipulates that each contracting State recognize the validity of the certificates of airworthiness and licenses issued by other contracting States as long as they meet the minimum standards of the ICAO. Consequently, it is submitted that the unilateral action of the USA, China, Mongolia, Australia, and the Philippines issuing the FOAC to the aircraft of other States is against the Convention. It is worry some that this breach of international law is likely to be followed by the European Union which is believed to be in preparation for its own unilateral application. The ICAO established by the Chicago Convention to be in charge of safe and orderly development of the international civil aviation has been in hard work to both upgrade and emphasize the safe operation of aircraft. As the result of these endeavors, it prepared a new Annex 19 to the Chicago Convention with the title of "Safety Management" and with the applicable date 14 November 2013. It is this Annex and other ICAO documents relevant to the safety that the contracting States to the Chicago Convention have to observe. Otherwise, it is the economical burden due to probable delay in issuing the FOAC and bureaucracies combined with many different paperworks and regulations depending on where the aircraft is flown. It is exactly to avoid this type of confusion and waste that the Chicago Convention aimed at when it was adopted in 1944. The State of the operator shall establish a system for both the certification and the continued surveillance of the operator in accordance with ICAO SARPs to ensure that the required standards of operations are maintained. Certainly the operator shall meet and maintain the requirements established by the States in which it operate. The authority of a State stops where the authority of another State intervenes or where the former has yielded its power by an international agreement for the sake of international cooperation. Hence, it is not within the realm of the State to issue FAOC towards foreign operators for the reason that these foreign operators are flying in and out of the State. Furthermore, there are other safety audits such as ICAO USOAP, IATA IOSA, FAA IASA, and EU SAFA that assure the safe operation of the aircraft, but within the limit of their power and in compliance with the ICAO SARPs. If the safety level of any operator is not satisfactory, the operator could be banned to operate in the contracting States with watchful eyes until the ICAO SARPs are met. This time-honoured practice has been applied without any serious problems. Besides, we have the new Annex 19 to strengthen and upgrade with easy reference for contracting States. We don't have no reason to introduce additional burden to the States by unilateral actions of some States. These actions have to be corrected. On the other hand, when it comes to the carriage of the Personal or Pilot Log Book, the Korean regulation requiring it is in contrast with other relevant provisions of USA, USOAP, IOSA, and SAFA. The Chicago Convention requires in its Articles 29 and 34 only the carriage of the Journey Log Book and some other certificates, but do not mention the Personal Log Book at all. Paragraph 5.1.1.1 of Annex 1 to the Chicago Convention even makes it clear that the carriage in the aircraft of the Personal Log Book is not required on international flights. The unique Korean regulation in this regards giving the unnecessary burden to the national flag air carriers has to be lifted at once.

  • PDF

A Morphologic Study of head and face for Sasang Constitution (사상체질별(四象體質別) 두면부(頭面部)의 형태학적(形態學的) 특징(特徵))

  • Ko, Byung-Hee;Song, Il-Byung;Cho, Yong-Jin;Choi, Chang-Seok;Kim, Jong-Weon;Hong, Suck-CHull;Lee, Eui-Ju;Lee, Sang-Yong;Seo, Jeong-Sug
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.101-186
    • /
    • 1996
  • The clinical application of constitutional Diagnosis is the most important part of Sasang constitutional medicine. It has been studied in various way. However, the study of morphologic characteristics on the face is applied for the first time. For quantitative analysis of the correlation between the sasang constitution and the shape of the face, the head-facial part of 170 cases were measured by Martin's measurement and analysis of a) the measurement value of height and the component ratio from the Gnathion to each part of face by constitution. b) the measurement value of depth and the component ratio from T-projected to each part of the face by constitution. c) the measurement value of breadth and component ratio between each parts of the facial breadth by constitution. d) the ratio of square on every part of face by constitution. e) the characteristics on each part of the face by constitution. f) the contour line of the forehead. g) the result of discriminant analysis about the constitution. Authors obtained the results from the study as follows; 1. The characteristics of Taeum-IN (1) The measurement value of Height, Breadth, T-Projected had a tendency to maximum value in general. (2) The value of lower opthal height and the square of lower opthal part was maximum. (3) The value of Pronasal T-projected length and Subnasal T-projected length was minimum, so Taeum-In has characteristics of depression in middle face, nasal part. (4) In the ratio of Breadth, T-Projected, T-Projected was minimum. (5) It was maximum that the square of nose, Alare, Middle face, Lower face and it was minimum that the square of eye. The square of nose, Alare, Middle facc, Lower face was maximum and the square of eye was minimum. (6) The curvature of the eyebrow was minimum. (7) The projection of jaw (Pogonion T-projection length) was maximum. (8) The breadth of eye was minimum. (9) There was a tendency that the projection of the forehead to the right in general. 2. The characteristics of Soeum-In (1) In all cases of projected length the measurement value was minimum. (2) The value of lower opthal height and the square of lower opthal part was minimum. (3) By the Pupulare T-projected length, the value of Pronasal T-projected length and Subnasal T-projected length was minimum, so the Soeum In's face shape is flat. (4) The square of eye, mouth, forehead was maximum and the square of nose, Alare, Middle face, Lower face was minimum. (5) The curvature of the eyebrow was maximum. (6) The projection of mouth was minimum. (7) The jaw was flat. (8) The breadth of eye was maximum. (9) There was a tendency that the projection of the forehead to the left in general. 3. The characteristics of Soyang-In. (1) In most cases of 고경 length the measurement value was minimum. (2) By the Pupulare T-projected length, each ratio of projected length was maximum, so the Soyang-In's face shape has many protrusions (3) In the ratio of Breadth, T-Projected, T-Projected was maximum. (4) The square of mouth was minimum. (5) The inclination of the forehead was minimum. (6) The projection of mouth was maximum. (7) The breadth of eye was minimum. (8) There was a tendency that the projection of the forehead to the left in general. (9) The middle face was protruded. 4. Discriminant about the constitution. According to the result of discriminant, the accuracy probability of discriminant was 85.58% in total and Taeum-In was 90.5%, Soeum-In was 70.8%, Soyang-In was 89.5%. The accuracy probability of discriminant about 3 constitutional group increased by 49.03% than the accident probility 36.55% 5. Suggestion (1) The study which gather and analysis the data should be continued. (2) The study which subdivide the characteristics of each part of the face by the constitution should be continued. (3) The analysis method about Moire should be supplement. (4) The study about the morphologic characteristics of the whole body should be continued. (5) Computer program of constitution diagnosis should be developed. (6) To increase utility of this method, the measurement should be automation.

  • PDF

Requirement and Perception of Parents on the Subject of Home Economics in Middle School (중학교 가정교과에 대한 학부모의 인식 및 요구도)

  • Shin Hyo-Shick;Park Mi-Soog
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.3 s.41
    • /
    • pp.1-22
    • /
    • 2006
  • The purpose of this study is that I should look for a desirous directions about home economics by studying the requirements and perception of the high school parents who have finished the course of home economics. It was about 600 parents whom I have searched Seoul-Pusan, Ganwon. Ghynggi province, Choongcheong-Gyungsang province, Cheonla and Jeju province of 600, I chose only 560 as apparently suitable research. The questions include 61 requirements about home economics and one which we never fail to keep among the contents, whenever possible and one about the perception of home economics aims 11 about the perception of home economics courses and management. The collections were analyzed frequency, percent, mean. standard deviation t-test by using SAS program. The followings is the summary result of studying of it. 1. All the boys and girls learning together about the Idea of healthy lives and desirous human formulation and knowledge together are higher. 2. Among the teaching purposes of home economics, the item of the scientific principle and knowledge for improvements of home life shows 15.7% below average value. 3. The recognition degree about the quality of home economics is highly related with the real life, and about the system. we recognize lacking in periods and contents of home economics field and about guiding content, accomplishment and application qualities are higher regardless of sex. 4. The important term which we should emphasize in the subject of home economics is family part. 5. Among the needs of home economic requirement in freshman, in the middle unit, their growth and development are higher than anything else, representing 4.11, and by contrast the basic principle and actuality is 3.70, which is lowest among them. 6. In the case of second grade requirement of home economics content for parents in the middle unit young man and consuming life is 4.09 highest. 7. In the case of 3rd grade requirement of economics contents in the middle unit the choice of coming direction and job ethics is highest 4.16, and preparing meals and evaluation is lowest 3.50.

  • PDF

A Study on improvement of curriculum in Nursing (간호학 교과과정 개선을 위한 조사 연구)

  • 김애실
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.1-16
    • /
    • 1974
  • This Study involved the development of a survey form and the collection of data in an effort-to provide information which can be used in the improvement of nursing curricula. The data examined were the kinds courses currently being taught in the curricula of nursing education institutions throughout Korea, credits required for course completion, and year in-which courses are taken. For the purposes of this study, curricula were classified into college, nursing school and vocational school categories. Courses were directed into the 3 major categories of general education courses, supporting science courses and professional education course, and further subdirector as. follows: 1) General education (following the classification of Philip H. phoenix): a) Symbolics, b) Empirics, c) Aesthetics. 4) Synthetics, e) Ethics, f) Synoptic. 2) Supporting science: a) physical science, b) biological science, c) social science, d) behavioral science, e) Health science, f) Educations 3) Professional Education; a) basic courses, b) courses in each of the respective fields of nursing. Ⅰ. General Education aimed at developing the individual as a person and as a member of society is relatively strong in college curricula compared with the other two. a) Courses included in the category of symbolics included Korean language, English, German. Chines. Mathematics. Statics: Economics and Computer most college curricula included 20 credits. of courses in this sub-category, while nursing schools required 12 credits and vocational school 10 units. English ordinarily receives particularly heavy emphasis. b) Research methodology, Domestic affair and women & courtney was included under the category of empirics in the college curricula, nursing and vocational school do not offer this at all. c) Courses classified under aesthetics were physical education, drill, music, recreation and fine arts. Most college curricula had 4 credits in these areas, nursing school provided for 2 credits, and most vocational schools offered 10 units. d) Synoptic included leadership, interpersonal relationship, and communications, Most schools did not offer courses of this nature. e) The category of ethics included citizenship. 2 credits are provided in college curricula, while vocational schools require 4 units. Nursing schools do not offer these courses. f) Courses included under synoptic were Korean history, cultural history, philosophy, Logics, and religion. Most college curricular 5 credits in these areas, nursing schools 4 credits. and vocational schools 2 units. g) Only physical education was given every Year in college curricula and only English was given in nursing schools and vocational schools in every of the curriculum. Most of the other courses were given during the first year of the curriculum. Ⅱ. Supporting science courses are fundamental to the practice and application of nursing theory. a) Physical science course include physics, chemistry and natural science. most colleges and nursing schools provided for 2 credits of physical science courses in their curricula, while most vocational schools did not offer t me. b) Courses included under biological science were anatomy, physiologic, biology and biochemistry. Most college curricula provided for 15 credits of biological science, nursing schools for the most part provided for 11 credits, and most vocational schools provided for 8 units. c) Courses included under social science were sociology and anthropology. Most colleges provided for 1 credit in courses of this category, which most nursing schools provided for 2 creates Most vocational school did not provide courses of this type. d) Courses included under behavioral science were general and clinical psychology, developmental psychology. mental hygiene and guidance. Most schools did not provide for these courses. e) Courses included under health science included pharmacy and pharmacology, microbiology, pathology, nutrition and dietetics, parasitology, and Chinese medicine. Most college curricula provided for 11 credits, while most nursing schools provide for 12 credits, most part provided 20 units of medical courses. f) Courses included under education included educational psychology, principles of education, philosophy of education, history of education, social education, educational evaluation, educational curricula, class management, guidance techniques and school & community. Host college softer 3 credits in courses in this category, while nursing schools provide 8 credits and vocational schools provide for 6 units, 50% of the colleges prepare these students to qualify as regular teachers of the second level, while 91% of the nursing schools and 60% of the vocational schools prepare their of the vocational schools prepare their students to qualify as school nurse. g) The majority of colleges start supporting science courses in the first year and complete them by the second year. Nursing schools and vocational schools usually complete them in the first year. Ⅲ. Professional Education courses are designed to develop professional nursing knowledge, attitudes and skills in the students. a) Basic courses include social nursing, nursing ethics, history of nursing professional control, nursing administration, social medicine, social welfare, introductory nursing, advanced nursing, medical regulations, efficient nursing, nursing english and basic nursing, College curricula devoted 13 credits to these subjects, nursing schools 14 credits, and vocational schools 26 units indicating a severe difference in the scope of education provided. b) There was noticeable tendency for the colleges to take a unified approach to the branches of nursing. 60% of the schools had courses in public health nursing, 80% in pediatric nursing, 60% in obstetric nursing, 90% in psychiatric nursing and 80% in medical-surgical nursing. The greatest number of schools provided 48 crudites in all of these fields combined. in most of the nursing schools, 52 credits were provided for courses divided according to disease. in the vocational schools, unified courses are provided in public health nursing, child nursing, maternal nursing, psychiatric nursing and adult nursing. In addition, one unit is provided for one hour a week of practice. The total number of units provided in the greatest number of vocational schools is thus Ⅲ units double the number provided in nursing schools and colleges. c) In th leges, the second year is devoted mainly to basic nursing courses, while the third and fourth years are used for advanced nursing courses. In nursing schools and vocational schools, the first year deals primarily with basic nursing and the second and third years are used to cover advanced nursing courses. The study yielded the following conclusions. 1. Instructional goals should be established for each courses in line with the idea of nursing, and curriculum improvements should be made accordingly. 2. Course that fall under the synthetics category should be strengthened and ways should be sought to develop the ability to cooperate with those who work for human welfare and health. 3. The ability to solve problems on the basis of scientific principles and knowledge and understanding of man society should be fostered through a strengthening of courses dealing with physical sciences, social sciences and behavioral sciences and redistribution of courses emphasizing biological and health sciences. 4. There should be more balanced curricula with less emphasis on courses in the major There is a need to establish courses necessary for the individual nurse by doing away with courses centered around specific diseases and combining them in unified courses. In addition it is possible to develop skill in dealing with people by using the social setting in comprehensive training. The most efficient ratio of the study experience should be studied to provide more effective, interesting education Elective course should be initiated to insure a man flexible, responsive educational program. 5. The curriculum stipulated in the education law should be examined.

  • PDF

A Study on Legal and Institutional Improvement Measures for the Effective Implementation of SMS -Focusing on Aircraft Accident Investigation-

  • Yoo, Kyung-In
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.2
    • /
    • pp.101-127
    • /
    • 2017
  • Even with the most advanced aviation technology benefits, aircraft accidents are constantly occurring while air passenger transportation volume is expected to double in the next 15 years. Since it is not possible to secure aviation safety only by the post aircraft accident safety action of accident investigations, it has been recognized and consensus has been formed that proactive and predictive prevention measures are necessary. In this sense, the aviation safety management system (SMS) was introduced in 2008 and has been carried out in earnest since 2011. SMS is a proactive and predictive aircraft accident preventive measure, which is a mechanism to eliminate the fundamental risk factors by approaching organizational factors beyond technological factors and human factors related to aviation safety. The methodology is to collect hazards in all the sites required for aircraft operations, to build a database, to analyze the risks, and through managing risks, to keep the risks acceptable or below. Therefore, the improper implementation of SMS indicates that the aircraft accident prevention is insufficient and it is to be directly connected with the aircraft accident. Reports of duty performance related hazards including their own errors are essential and most important in SMS. Under the policy of just culture for voluntary reporting, the guarantee of information providers' anonymity, non-punishment and non-blame should be basically secured, but to this end, under-reporting is stagnant due to lack of trust in their own organizations. It is necessary for the accountable executive(CEO) and senior management to take a leading role to foster the safety culture initiating from just culture with the safety consciousness, balancing between safety and profit for the organization. Though a Ministry of Land, Infrastructure and Transport's order, "Guidance on SMS Implementation" states the training required for the accountable executive(CEO) and senior management, it is not legally binding. Thus it is suggested that the SMS training completion certificates of accountable executive(CEO) and senior management be included in SMS approval application form that is legally required by "Korea Aviation Safety Program" in addition to other required documents such as a copy of SMS manual. Also, SMS related items are missing in the aircraft accident investigation, so that organizational factors in association with safety culture and risk management are not being investigated. This hinders from preventing future accidents, as the root cause cannot be identified. The Aircraft Accident Investigation Manuals issued by ICAO contain the SMS investigation wheres it is not included in the final report form of Annex 13 to the Convention on International Civil Aviation. In addition, the US National Transportation Safety Board(NTSB) that has been a substantial example of the aircraft accident investigation for the other accident investigation agencies worldwide does not appear to expand the scope of investigation activities further to SMS. For these reasons, it is believed that investigation agencies conducting their investigations under Annex 13 do not include SMS in the investigation items, and the aircraft accident investigators are hardly exposed to SMS investigation methods or techniques. In this respect, it is necessary to include the SMS investigation in the organization and management information of the final report format of Annex 13. In Korea as well, in the same manner, SMS item should be added to the final report format of the Operating Regulation of the Aircraft and Railway Accident Investigation Board. If such legal and institutional improvement methods are complemented, SMS will serve the purpose of aircraft accident prevention effectively and contribute to the improvement of aviation safety in the future.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Research for Space Activities of Korea Air Force - Political and Legal Perspective (우리나라 공군의 우주력 건설을 위한 정책적.법적고찰)

  • Shin, Sung-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.18
    • /
    • pp.135-183
    • /
    • 2003
  • Aerospace force is a determining factor in a modem war. The combat field is expanding to space. Thus, the legitimacy of establishing aerospace force is no longer an debating issue, but "how should we establish aerospace force" has become an issue to the military. The standard limiting on the military use of space should be non-aggressive use as asserted by the U.S., rather than non-military use as asserted by the former Soviet Union. The former Soviet Union's argument is not even strongly supported by the current Russia government, and realistically is hard to be applied. Thus, the multi-purpose satellite used for military surveillance or a commercial satellite employed for military communication are allowed under the U.S. principle of peaceful use of space. In this regard, Air Force may be free to develop a military surveillance satellite and a communication satellite with civilian research institute. Although MTCR, entered into with the U.S., restricts the development of space-launching vehicle for the export purpose, the development of space-launching vehicle by the Korea Air Force or Korea Aerospace Research Institute is beyond the scope of application of MTCR, and Air Force may just operate a satellite in the orbit for the military purpose. The primary task for multi-purpose satellite is a remote sensing; SAR sensor with high resolution is mainly employed for military use. Therefore, a system that enables Air Force, the Korea Aerospace Research Institute, and Agency for Defense Development to conduct joint-research and development should be instituted. U.S. Air Force has dismantled its own space-launching vehicle step by step, and, instead, has increased using private space launching vehicle. In addition, Military communication has been operated separately from civil communication services or broadcasting services due to the special circumstances unique to the military setting. However, joint-operation of communication facility by the military and civil users is preferred because this reduces financial burden resulting from separate operation of military satellite. During the Gulf War, U.S. armed forces employed commercial satellites for its military communication. Korea's participation in space technology research is a little bit behind in time, considering its economic scale. In terms of budget, Korea is to spend 5 trillion won for 15 years for the space activities. However, Japan has 2 trillion won annul budget for the same activities. Because the development of space industry during initial fostering period does not apply to profit-making business, government supports are inevitable. All space development programs of other foreign countries are entirely supported by each government, and, only recently, private industry started participating in limited area such as a communication satellite and broadcasting satellite, Particularly, Korea's space industry is in an infant stage, which largely demands government supports. Government support should be in the form of investment or financial contribution, rather than in the form of loan or borrowing. Compared to other advanced countries in space industry, Korea needs more budget and professional research staff. Naturally, for the efficient and systemic space development and for the prevention of overlapping and distraction of power, it is necessary to enact space-related statutes, which would provide dear vision for the Korea space development. Furthermore, the fact that a variety of departments are running their own space development program requires a centralized and single space-industry development system. Prior to discussing how to coordinate or integrate space programs between Agency for Defense Development and the Korea Aerospace Research Institute, it is a prerequisite to establish, namely, "Space Operations Center"in the Air Force, which would determine policy and strategy in operating space forces. For the establishment of "Space Operations Center," policy determinations by the Ministry of National Defense and the Joint Chief of Staff are required. Especially, space surveillance system through using a military surveillance satellite and communication satellite, which would lay foundation for independent defense, shall be established with reference to Japan's space force plan. In order to resolve issues related to MTCR, Air Force would use space-launching vehicle of the Korea Aerospace Research Institute. Moreover, defense budge should be appropriated for using multi-purpose satellite and communication satellite. The Ministry of National Defense needs to appropriate 2.5 trillion won budget for space operations, which amounts to Japan's surveillance satellite operating budges.

  • PDF