• 제목/요약/키워드: application generators

검색결과 177건 처리시간 0.033초

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

개체지향기반 안정도 해석 프로그램 개발 및 적용 (Development and Application of Power System Stability Analysis Program Using OOP)

  • 박지호
    • 에너지공학
    • /
    • 제11권3호
    • /
    • pp.194-202
    • /
    • 2002
  • 본 논문은 객체지향 프로그램(OOP)을 사용하여 광양제철소 전력계통의 과도안정도를 모의한다. OOP는 절차식 프로그램보다 유연한 방법으로서 동적인 시스템의 모의에 여러 가지 장점이 있다. 시스템의 변화가 있으면 프로그램 전체을 수정하는 대신 필요한 부분만을 수정하면 되므로, 프로그램의 유지 및 보수가 매우 용이하다. 본 논문에서는 OOP를 이용하여 동적인 시스템의 해석을 위한 유연한 방법을 제시하였다. 시스템을 직접 사용자가 그려서 전력조류계산과 동적 안정도를 모의할 수 있는 사용자 인터페이스를 구현하여 17기의 동기발전기와 25기의 동기전동기로 구성되는 광양제철소 전력계통의 동적 안정도 해석에 적용하였다.

A Methodology for Integrating Business Process and Simulation for Business Process Redesign

  • Kim, Joong-In;Yim, Dong-Soon;Choi, Jung-Sang;Kim, Keun-Chong
    • International Journal of Quality Innovation
    • /
    • 제6권1호
    • /
    • pp.74-97
    • /
    • 2005
  • IDEF0 is the IEEE standard for functional enterprise modeling and has been used for business process modeling or process mapping in US and Europe. But it does not reflect the potential benefits of modeling and simulation of the dynamic aspects of an enterprise or a system. On the other hand, simulation tools concentrate mostly on the simulation of material flows and are difficult to include information flows and control flows. Additionally, the simulation models that include elements such as queues, event generators and process nodes is a visual interactive representation for the model builder, but is inconvenient for the domain expert. In an attempt to fill that void, we provide an integration of business process and simulation models in this paper. An enhancement of the IDEF0, called parameterized IDEF0, is proposed and its conversion mechanism to network simulation model is developed. Using this methodology, business process models for alternative systems can be evaluated and compared through simulation on time, cost, and quality metrics. As an application of the proposed methodology, economic evaluation of EDI (Electronic Data Interchange) for time-based BPR (Business Process Redesign) is demonstrated. In addition to BPR, the developed methodology may be further integrated with ABC (Activity Based Costing), TQM (Total Quality Management), and economic evaluation of information systems.

전력계통안정화장치(PSS) 수력발전소 적용분석 (The Application Analysis of Power System Stabilizer in Hydraulic power plant)

  • 옥연호;임재일;박지군;곽원구;이광연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.63-65
    • /
    • 2007
  • Recently with increase consumption of electric power, the scale of the electric system becomes bigger and complex. Then, it is increasing the hardship in the operation of electric system and the continuance of stability. Especially, as the differences between demand and supply in electric power keeping low frequency oscillating attenuation from electric power have been very important in the continuance part of stability. The more control time of electricity system is getting faster with digitalization the more stability of electricity system is getting worse. As solutions of these problems, by establishing Power System Stabilizing Controller putting PSS output signal and putting damping to vibration of the rotor at generators's AVR in area where is oscillated, We are willing to contribute the electricity system by holding in generator output vibration.

  • PDF

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

하소온도변화에 따른 초음파절삭기용 PMN-PNN-PZT 세라믹스의 압전 및 유전 특성 (Piezoelectric and Dielectric Properties of PMN-PNN-PZT Ceramics for Ultrasonic Generator with Calcination Temperature)

  • 류주현;김승원;서동희;이은섭;최낙구;정회승
    • 한국전기전자재료학회논문지
    • /
    • 제30권3호
    • /
    • pp.152-156
    • /
    • 2017
  • In this paper, $Pb(Mn_{1/3}Nb_{2/3})_{0.07}(Ni_{1/3}Nb_{2/3})_{0.10}(Zr_{0.5}Ti_{0.5})_{0.83}O_3$ ceramics were fabricated by the conventional solid state method to obtain excellent dielectric properties for ultrasonic generators. The effects of 2nd calcination temperature on their microstructure and piezoelectric properties were systematically investigated. The tetragonality increased in the ceramics when 2nd calcination temperature increased to the optimized temperature at $750^{\circ}C$. At that temperature, excellent physical properties ($d_{33}=352\;pC/N$, ${\varepsilon}_r=1,687$, $k_p=0.570$, $Q_m=1,640$) were obtained for ultrasonic generator application.

Analysis of Harmonic Currents Propagation on the Self-Excited Induction Generator with Nonlinear Loads

  • Nazir, Refdinal
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1935-1943
    • /
    • 2014
  • In recent years, the induction machines are increasingly being used as self-excited induction generators (SEIG). This generator is especially widely employed for small-scale power plants driven by renewable energy sources. The application of power electronic components in the induction generator control (IGC) and the loading of SEIG using nonlinear loads will generate harmonic currents. This paper analyzes the propogation of harmonic currents on the SEIG with nonlinear loads. Transfer function method in the frequency domain is used to calculate the gain and phase angle of each harmonic current component which are generated by a nonlinear loads. Through the superposition approach, this method has also been used to analyze the propagation of harmonic currents from nonlinear load to the stator windings. The simulation for the propagation of harmonic currents for a 4 pole, 1.5 kW, 50Hz, 3.5A, Y-connected, rotor-cage SEIG with energy-saving lamps, have provided results almost the same with the experiment. It can prove that the validity of the proposed models and methods. The study results showed that the propagation of harmonic currents on the stator windings rejects high order harmonics and attenuates low order harmonics, consequently THDI diminish significantly on the stator windings.

A Study on SFCL with IGBT Based DC Circuit Breaker in Electric Power Grid

  • Bae, SunHo;Kim, Hongrae;Park, Jung-Wook;Lee, Soo Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1805-1811
    • /
    • 2017
  • Recently, DC systems are considered as efficient electric power systems for renewable energy based clean power generators. This discloses several critical issues that are required to be considered before the installation of the DC systems. First of all, voltage/current switching stress, which is aggravated by large fault current, might damage DC circuit breakers. This problem can be simply solved by applying a superconducting fault current limiter (SFCL) as proposed in this study. It allows a simple use of insulated-gate bipolar transistors (IGBTs) as a DC circuit breaker. To evaluate the proposed resistive type SFCL application to the DC circuit breaker, a DC distribution system is composed of the practical line impedances from the real distribution system in Do-gok area, Korea. Also, to reflect the distributed generation (DG) effects, several DC-to-DC converters are applied. The locations and sizes of the DGs are optimally selected according to the results of previous studies on DG optimization. The performance of the resistive type SFCL applied DC circuit breaker is verified by a time-domain simulation based case study using the power systems computer aided design/electromagnetic transients including DC (PSCAD/ EMTDC(R)).

GROUP-FREENESS AND CERTAIN AMALGAMATED FREENESS

  • Cho, Il-Woo
    • 대한수학회지
    • /
    • 제45권3호
    • /
    • pp.597-609
    • /
    • 2008
  • In this paper, we will consider certain amalgamated free product structure in crossed product algebras. Let M be a von Neumann algebra acting on a Hilbert space Hand G, a group and let ${\alpha}$ : G${\rightarrow}$ AutM be an action of G on M, where AutM is the group of all automorphisms on M. Then the crossed product $\mathbb{M}=M{\times}{\alpha}$ G of M and G with respect to ${\alpha}$ is a von Neumann algebra acting on $H{\bigotimes}{\iota}^2(G)$, generated by M and $(u_g)_g{\in}G$, where $u_g$ is the unitary representation of g on ${\iota}^2(G)$. We show that $M{\times}{\alpha}(G_1\;*\;G_2)=(M\;{\times}{\alpha}\;G_1)\;*_M\;(M\;{\times}{\alpha}\;G_2)$. We compute moments and cumulants of operators in $\mathbb{M}$. By doing that, we can verify that there is a close relation between Group Freeness and Amalgamated Freeness under the crossed product. As an application, we can show that if $F_N$ is the free group with N-generators, then the crossed product algebra $L_M(F_n){\equiv}M\;{\times}{\alpha}\;F_n$ satisfies that $$L_M(F_n)=L_M(F_{{\kappa}1})\;*_M\;L_M(F_{{\kappa}2})$$, whenerver $n={\kappa}_1+{\kappa}_2\;for\;n,\;{\kappa}_1,\;{\kappa}_2{\in}\mathbb{N}$.

Tabu Search를 이용한 TCSC의 점호각 제어용 퍼지 제어기의 설계 (Design of Fuzzy Controller for Firing Angle of TCSC Using Tabu Search)

  • 김우근;황기현;문경준;김형수;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.37-39
    • /
    • 2000
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on Power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small of large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC. we performed the computer simulation for single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows the better control performance than PD controller.

  • PDF