• 제목/요약/키워드: apparent power

검색결과 273건 처리시간 0.027초

Size Effect on Axial Compressive Strength of Notched Concrete Specimens

  • Yi, Seong-Tae;Kim, Jin-Keun
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.43-50
    • /
    • 2002
  • In this study, size effect tests were conducted on axial compressive strength of concrete members. An experiment of Mode I failure, which is one of two representative compressive failure modes, was carried out by using dimensionally proportional cylindrical specimens (CS). An adequate notch length was taken from the experimental results obtained from the compressive strength experiment of various initial notch lengths. Utilizing the notch length, specimen sizes were then varied. In addition, new parameters for the modified size effect law (MSEL) were suggested using Levenberg-Marquardt's least square method (LSM). The test results show that size effect was apparent for axial compressive strength of cracked specimens. Namely, the effect of initial notch length on axial compressive strength size effect was apparent.

  • PDF

저온 plasma 기술에 의한 PET 극세사직물의 날염성 개선(I) (Improvement of Printing Properties of PET Micro Filament Fabrics Using Low Temperature Plasma Technology(I))

  • 조규민;이종훈
    • 한국염색가공학회지
    • /
    • 제7권1호
    • /
    • pp.1-9
    • /
    • 1995
  • In order to improve dyeability of poly(ethylene terephthalate)(PET) micro filament fabrics, the effect of the prior oxygen low temperature plasma on the subsequent dyeing(deep dyeing, printing) was examined in various conditions. The apparent concentration of dyed PET micro filament fabrics was increased by $O_{2}$plasma treatment. Higher discharge power levels and higher reactor pressure values created more significant effect. The wettability was significantly increased by $O_{2}$ plasma treatment. Therefore, it is predicted that introducing hydrophilic group on the surface of material can improve the apparent concentration of PET micro filament fabrics.

  • PDF

복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 탁소전력의 궤적변화 (A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power trajectory in Complex plane)

  • 권오상;김철환;박남옥;채영무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.310-312
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load the oscillation can be severe and even increase largely and finally the out-of-step condition may occur During the power swing and out-of-step conditions, the a apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

  • PDF

역률보상회로를 이용한 이동통신 중계기의 에너지 절감에 관한 연구 (Study on the energy savings in the mobile communication repeater using a power factor correction circuit)

  • 임병철;윤원식
    • 한국정보통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.1854-1860
    • /
    • 2014
  • 본 논문에서 이동통신 중계기를 위한 에너지 절감방법에 대한 연구를 수행하였다. 현재 실제 현장에서 서비스하고 있는 DB(Dual Band)소형 중계기에 있는 SMPS(Switching Mode Power Supply)에 PFC(Power Factor Correction)를 추가하여 전력소모를 감소하였으며, 이를 실제 구현하여 검증함으로써 실증된 결과를 도출하였다. 실증결과 장비 1식당 약 38.9% 피상전력 개선효과를 확인하였으며, 이를 연간으로 환산해 보면 약 230.43kWh의 에너지 절감효과가 있다.

ER유체를 작동유체로 하는 클러치의 제작 및 성능 실험 (Design and Performance Test of the ER Fluid Clutch)

  • 장성철;박창수;이종두
    • 한국기계가공학회지
    • /
    • 제3권1호
    • /
    • pp.84-89
    • /
    • 2004
  • This study is a basic one for application of ER Fluid to fluid power systems. By mixing silicone oil with zeolite particles, four kinds of ER fluids were made, in which the weight ratio of zeolite particles are different. We examined how the Yield shear stress and Bingham characteristics of the ER fluids are effected by varying electric field intensity. We designed and constructed a disk type power transmission clutch in which ER fluid fills and this ER fluid transmits the power of drive shaft to the driven shaft. With this equipment, the revolution transmission ratio from the chive shaft to the driven shaft by varying electric field density of the ER fluid was examined.

  • PDF

절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성 (Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil)

  • 윤진열;주형준;구선근;박기준
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성 (Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer)

  • 윤진열;주형준;구선근;박기준
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

A Brief Scrutiny of Malawi's Policy on Nuclear Power

  • Katengeza, Estiner Walusungu
    • Journal of Radiation Protection and Research
    • /
    • 제45권4호
    • /
    • pp.147-153
    • /
    • 2020
  • Background: Malawi's 2018 National Energy Policy includes nuclear power as an energy option with an operational 100 MW targeted for 2035. Materials and Methods: This paper challenges the scope of the policy on nuclear power by reviewing its implementation strategy and comparing it to: the strategy established for coal in the same policy; some experiences from other countries; and documents by the International Atomic Energy Agency (IAEA) relating to establishing a national position on nuclear power and infrastructural requirements for a nuclear power program. Results and Discussion: It is found that the pro-nuclear position is uninformed, and targets are unrealistic owing to a lack of understanding of nature of nuclear power including the requirements for safety, security and safeguards, and nuclear infrastructure. It is apparent that neither consultation nor a proper analysis were comprehensively conducted for nuclear. Though the national energy policy suggests a national position for nuclear energy, the content does not demonstrate that the position was arrived at knowledgeably. Conclusion: Thus, nuclear power may presently be viewed as a potential energy option that is yet to be seriously considered. It is important to build an appropriate level of literacy on nuclear science and technology for policy makers, key stakeholders, and the public to be better positioned for strategizing on nuclear power.

Intelligent Coordination Method of Multiple Distributed Resources for Harmonic Current Compensation in a Microgrid

  • Kang, Hyun-Koo;Yoo, Choel-Hee;Chung, Il-Yop;Won, Dong-Jun;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.834-844
    • /
    • 2012
  • Nonlinear electronic loads draw harmonic currents from the power grids that can cause energy loss, miss-operation of power equipment, and other serious problems in the power grids. This paper proposes a harmonic compensation method using multiple distributed resources (DRs) such as small distributed generators (DGs) and battery energy storage systems (BESSs) that are integrated to the power grids through power inverters. For harmonic compensation, DRs should inject additional apparent power to the grids so that certain DRs, especially operated in proximity to their rated power, may possibly reach their maximum current limits. Therefore, intelligent coordination methods of multiple DRs are required for efficient harmonic current compensation considering the power margins of DRs, energy cost, and the battery state-of-charge. The proposed method is based on fuzzy multi-objective optimization so that DRs can cooperate with other DRs to eliminate harmonic currents with optimizing mutually conflicting multi-objectives.

전자기장의 분광 에너지에 기반한 MT 및 GDS 자료의 전처리 기법 연구 (Pre-screening technique for MT and GDS data processing based on the spectral power of Electromagnetic field)

  • 양준모;권병두
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.253-258
    • /
    • 2006
  • 한반도는 고도의 산업화와 도시화로 인해 깨끗한 MT 및 GDS 자료를 획득하기 매우 어렵다. 이러한 환경에서는 적당한 신호 대 잡음비를 가지는 자료를 선별하는 전처리 과정이 필수적이다. 본 연구에서는 전자기장의 분광에너지에 기반한 자동 전처리 과정(RMP)을 한반도의 현실적인 상황을 고려하여 수정하였고, 이를 한반도 내륙에서 획득된 총 7 측점의 MT 자료에 적용하였다. 전반적으로, RMP 기법은 주기 10초 대역 부근에서 주파수에 따른 전기비저항과 위상의 연결성을 상당히 향상시켰다. 또한 RMP 기법에 의한 결과는 수작업으로 편집된 기존의 처리 결과와도 거의 유사였고, 특히 전기 비저항의 연결성면에서 그 우수성이 확인되었다.

  • PDF