• 제목/요약/키워드: apparent power

검색결과 273건 처리시간 0.034초

구동회로를 고려한 스위치드 릴럭턴스 전동기의 극호와 스위칭 조건에 따른 역율과 효율 특성 (Characteristic of efficiency and powerfactor according to condition by polearcs and switching an91e for switched reluctance motor considering driving circuits)

  • 박종원;김윤현;최재학;이주;김석태;김영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.702-704
    • /
    • 2001
  • This paper investigates efficiency and power factor of Switched Reluctance Motor (SRM) using Finite Element Method considered driving circuit. The efficiency and power factor are calculated in Input terminal and Output terminal respectively. When calculating power factor, apparent power is obtained by effective voltage and current because SRM is operated by switching of driving circuit. Efficiency is calculated by mechanical output and active power. Finally, the characteristics of efficiency and power factor in three proposed models are compared due to the switching pattern.

  • PDF

연고제(軟膏劑)의 경도(硬度)에 관한 연구(硏究)(III) -수종(數種)의 분말약제(粉末藥劑)가 연고제(軟膏劑)의 대수경도(對數硬度)에 미치는 영향(影響)- (The Study on the Hardness of Ointment (III) -Influences of Power on the Apparent Logarithmic Hardness of Ointments-)

  • 김종갑;김기성;이숙경
    • Journal of Pharmaceutical Investigation
    • /
    • 제5권3호
    • /
    • pp.66-73
    • /
    • 1975
  • The relationship between powders and apparent logarithmic hardness of ointments were clearly demonstrated. The followings were obtained as the results. 1. Apparent logarithmic hardness of ointment were affected by the powders such as zinc oxide, salicylic acid, soluble starch. and talc. 2. The ointments which are added powder have different two slops, $k_1\;and\;k_2$. 3. The slopes, $k_1\;and\;k_2$ were directly correlated and the critical points, were proportional to $k_1\;and\;k_2$ values. 4. The slope, ka is at least $6{\sim}91$ times more sensitive, than the slope, $k_1$, and 25 times more sensitive in average. It was suggested from the results that the quantity of powers which is added to the ointment must be within the critical point.

  • PDF

국산벤토나이트 현탁액의 유동학적 성질 (Rheological Studies on the Aqueous Suspension of Korean Bentonite)

  • 김은희;이계주
    • 약학회지
    • /
    • 제34권5호
    • /
    • pp.302-310
    • /
    • 1990
  • A study has been made of the Korean bentonite aqueous suspension contrast with American bentonite by means of XRD IR swelling, gel formation and rheogram at various conditions such as concentration, temperature and pH. The Korean bentonite was identified as montmorillonite clay containig a small proprotion of crystoballite and mordenite, and its swelling power were acceptable for requirements of Korean pharmacopeia regulations though its values were not satisfied. Korean bentonite swelled to 10 times and American one did to 15 times compared to its bulkiness of powder. The rheogram of Korean bentonite suspension reveals bulged pseudoplatic flow with yield value at higher concentration and pseudoplastic flow without yield value at lower concentration. The higher the concentration, the greater were the apparent viscosity and hysteresis loop. Korean bentonite suspension showed insignificant temperature dependence on both apparent viscosity and hysteresis loop and it was more temperature dependent on viscosity but less on hysteresis loop than those of American sample. The pH dependence was so high on viscosity that apparent minimum value was near pH 7 and maximum value at pH 3 or 7. The hysteresis loop appeared minimum over the pH range 5-7 and maximum near pH 3 or 11. The Korean bentonite was inferior to the American bentonite in swelling volume, gel formation, thioxotropy, however, it would be possible to improve the quality of Korean bentonite by developing the method of purification for bentonite clay.

  • PDF

회전식 점도계를 이용한 ERF의 겉보기 점도 특성 (Apparent Viscosity Properties of Electro-Rheological Fluid by Using Rotational Viscometer)

  • 장성철;이진우;김태형;박종근
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2001
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. Therefore, there are many practical applications using the ER fluids. ER effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of starch based ER fluid were reported. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply, The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to 200s$^{-1}$ in 2 minutes. This thesis presents Bingham properties of ER fluids subjected to temperature variations. The temperature dependence of the viscosity was determined for ER fluids consisting of 35 weight % starch particles in automatic transmission oil.

  • PDF

척추성형술에서 PMMA 주입에 의한 망상골의 압축강도 변화 연구 (The Study of Changes in Compressive Strength of Trabecular Bone with PMMA Injection in Vertebroplasty)

  • 문희옥;이문규;김정규;이태수;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.369-373
    • /
    • 2003
  • 골다공증에 의한 척추체의 압박골절은 뼈의 파단성 질병중에서 가장 흔하게 나타나는 증상이다 최근에 척추압박골절에 대한 의학적 치료방법으로 각광받고 있는 척추성형술은 골강화제를 주입함으로써 척추체를 강화하고 변형을 보정하며. 환자의 고통을 줄여준다. 그러나 종전 연구에서는 골강화제가 주입된 후 척추체의 기계적 특성 강화에 대한 연구가 전무했으므로, 본 연구에서는 PMMA의 물성을 바탕으로 돼지와 사체로부터 시편을 얻어 겉보기 밀도에 대한 순수 망상골과 PMMA가 주입된 망상골의 영률을 측정하였다. 겉보기밀도에 따른 영률은 순수망상골의 경우 멱급수의 형태를 가지며. PMMA가 주입된 망상골의 경우 선형적인 형태를 가졌다.

전압의 주파수 편의를 이용한 동기탈조 검출 알고리즘에 관한 연구 (A Study on the Out-of-Step Detection Algorithm using Frequency Deviation of the Voltage)

  • 소광훈;허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.175-181
    • /
    • 2004
  • The protection against transient instability and consequent out-of-step condition is a major concern for the utility industry. Unstable system may cause serious damage to system elements such as generators and transmission lines. Therefore, out-of-step detection is essential to operate a system safely. The detection of out-of-step is generally based upon the rate of movement of the apparent impedance. However such relay monitors only the apparent impedance which may not be sufficient to correctly detect all forms of out-of-step and cannot cope with out-of-step for a more complex type of instability such as very fast power swing. This paper presents the out-of-step detection algorithm using voltage frequency deviation. The digital filters based on discrete Fourier transforms (DFT) to calculate the frequency of a sinusoid voltage are used, and the generator angle is estimated using the deviation of the calculated frequency component of the voltage. The proposed out-of-step algorithm is based on the assessment of a transient stability using equal area criterion. The proposed out-of-step algorithm is verified and tested by using EMTP MODELS.

원통 및 구형교반조에서의 2단 Paddle 임펠러에 대한 소요동력 (Power Consumption for Double-Stage Paddle Impeller in Cylindrical and Spherical Agitated Vessels)

  • 이영세;최현국;히로타카 시다
    • 한국산업융합학회 논문집
    • /
    • 제9권4호
    • /
    • pp.247-253
    • /
    • 2006
  • Power consumption for double-stage paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained which was applied to both spherical and cylindrical vessel, when the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel which had a height equal to its diameter and had the same volume as the spherical vessel. The power consumption for the double-stage impeller was dependent upon the distance of among the impeller in the agitated vessels, as follows: $$f/2={\frac{C_L}{Re_G}}+{\frac{Ct}{2}}({\frac{C_tr}{Re_g}}+Re_g)^{-m}$$

  • PDF

송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발 (Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems)

  • 최면송;민병운;김기화;현승호;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

전기자동차 충전을 위한 고효율 무선전력전송 시스템 (Extremely high efficiency wireless power transfer system for EV charger)

  • 문상철;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.155-156
    • /
    • 2015
  • This paper proposes a high efficiency wireless power transfer system with an asymmetric 4-coil resonator. It presents a theoretical analysis, an optimal design method, and experimental results. In the proposed asymmetric 4-coil system, the primary side consists of a source coil and two transmitter coils which are called intermediate coils, and in the secondary side, a load coil serves as a receiver coil. In the primary side, two intermediate coils boost the apparent coupling coefficient at around the operating frequency. Because of this double boosting effect, the system with an asymmetric 4-coil resonator has a higher efficiency than the conventional symmetric 4-coil system. The prototype operates at 90 kHz ofswitching frequency and has 200 mm of the power transmission distance between the primary side and the secondary side. An AC-DC overall system efficiency of 96.56% has been achieved at 3.3 kW of output power.

  • PDF

복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화 (A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane)

  • 권오상;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권7호
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.