• Title/Summary/Keyword: apparatus for environment control

Search Result 46, Processing Time 0.023 seconds

Development of a Fixing Apparatus Available to Mount-and-detach ADCP on a Small Vessel (소형선박용 착.탈식 ADCP 고정장치 개발)

  • Hwang, Sang-Chul;Jeon, Dong-Chull;Kang, Jae-Hoon;Kim, Cheol-Soo
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.481-486
    • /
    • 2004
  • A portable apparatus mounting Acoustic Doppler Current Profilers (ADCP) to any small boat was developed to effectively measure currents in shallow and narrow coastal seas like the west coasts of Korea. Characteristics of the apparatus is that an underwater fish-shaped body protecting an ADCP is designed to reduce the drag during the cruise, which can be freely mounted and detached from a boat with a clamp. Several cruise outputs prove themselves that the apparatus is properly designed for the intended purpose, to minimize air bubbles and to control the submerged depth of the sensor.

Effect of Ethylene Removal on Fruit Quality of Oriental Pear during Storage (저장고 내의 에틸렌 제거가 배 과실의 품질에 미치는 영향)

  • Kim Ho-Cheol;Bae Kang-Soon;Bae Jong-Hyang;Jeon Kyung-Soo;Hong Jong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.15 no.1
    • /
    • pp.78-83
    • /
    • 2006
  • The objective of this study was to examine effect of ethylene removal apparatus on fruit quality of 'Niitaka' pear (Pyrus pyrifolia) in case of a double storage of apples and pears in a storage room. Ethylene and carbon dioxide concentration were efficiently decreased by the ethylene removal apparatus. Fruit weight loss was high at double storage of apples and pears (DAP) in a storage room compared with storage of pears. Fruit core browning was $5{\sim}22.5%$ at the fruits in DAP, but as setting ethylene removal apparatus it was not occurred till 90 days after storage. Soluble solids content and fruit peel hardness were not different among the treatments. Accordingly, a double storage of apples and pears in a storage room is possible as setting ethylene removal apparatus.

Study on the Thermal Properties of Electric Moxibustion Apparatus for Presenting Assessment Guideline in Korea (국내 평가 가이드라인 제시를 위한 전기식 온구기의 열특성에 관한 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • Objectives : To characterize the thermal properties of several Korean electric moxibustion apparatus and to suggest methods for improving their quality for related industry as well as the welfare of Korean. Methods : We reviewed previous literatures on traditional moxibustion to find necessary factors for electric moxibustion apparatus. We measured the thermal characteristics of electric moxibustion apparatus commercially available by using an automatic temperature acquisition system in a controlled environment. Uniformity and heat loss of the apparatus were also analysed. We followed the user's manuals of apparatus provided by manufacturers. Results : Temperature control of all apparatus could not be achieved by automatic manners. Most of them were dependent on user's discretion. Maximum temperatures obtained were barely in the therapeutic temperature of $40-45^{\circ}C$. Unnecessary heating of moxibustion parts was detected. Chemicals from moxa were not properly delivered to the human skin. Conclusions : Temperature control of all apparatus needs to be improved in terms of temperature setting, retention time and maximum temperature. Design should be altered to utilize pharmacological effects from moxa to obtain its maximum efficacy. User's manuals should be revised for its clarity.

  • PDF

Push-in Head Restraining Apparatus for Intracranial Self Stimulation Tasks in Rats

  • Roh, Mootaek;Jang, Il-Sung;Lee, Maan-Gee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.18 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Head restraining is an experimental technique that firmly secures the animal's head to a fixation apparatus for the precise control and sensing of behaviors. However, procedural and surgical difficulties and limitations have been obstructing the use of the technique in neurophysiological and behavioral experiments. Here, we propose a novel design of the head-restraining apparatus which is easy to develop and convenient for practical use. Head restraining procedure can be completed by sliding the head mounter, which is molded by dental cement during implantation surgery, into the port, which serves as matching guide rails for the mounter, of the fixation bar. So neither skull-attached plates nor screws for fixation are needed. We performed intracranial self stimulation experiment in rats using the newly designed device. Rats were habituated to acclimatize the head-restraint environment and trained to discriminate two spatially distinguished cues using a customized push-pull lever as an operandum. Direct electrical stimulation into the medial forebrain bundle served as reward. We confirmed that head restraining was stable throughout experiments and rats were able to learn to manipulate the lever after successful habituation. Our experimental framework might help precise control or sensing of behavior under head fixed rats using direct electrical brain stimulation as a reward.

Control Performance Investigation of Piezoelectric Actuators under Variation of External Heat Environment (외부 열적 환경 변화에 따른 압전작동기 제어성능 열화 고찰)

  • Han, Young-Min;Moon, Byung Koo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.10
    • /
    • pp.707-713
    • /
    • 2015
  • This paper proposes experimental results for control performance deterioration of a piezoelectric actuator under high temperature conditions due to external heat environment. In this work, a heat environment from 30 ℃ to 190 ℃ is established by a heat chamber which is capable of high temperature of heat environment. Inside the heat chamber, an experimental apparatus consisting of the stack type of piezoelectric actuator, laser sensor, gap sensor and temperature sensor is established. After evaluating temperature dependent blocking force, displacement and time response of a piezoelectric actuator inside the heat chamber, tracking control performances are evaluated under various temperature conditions via proportional-integral-derivative(PID) feedback controller. The desired position trajectory has a sinusoidal wave form with a fixed frequency. Control performances are experimentally evaluated at both room temperature and high temperature and presented in time domain.

Construction and Application of an Automated Apparatus for Calculating the Soil-Water Characteristic Curve (자동 흙-함수특성곡선 시험장치 구축 및 활용)

  • Song, Young-Suk;Lee, Nam-Woo;Hwang, Woong-Ki;Kim, Tae-Hyung
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.281-295
    • /
    • 2010
  • A new, automated apparatus is proposed for calculating the Soil-Water Characteristic Curve (SWCC), representing a simple and easily applied testing device for continuous measurements of the volumetric water content and suction of unsaturated soils. The use of this apparatus helps to avoid the errors that arise when performing experiments. Consequently, the apparatus provides greater accuracy in calculating the SWCC of unsaturated soils. The apparatus is composed of a pressure panel, flow cell, water reservoir, air bubble trap, balance, sample-preparation accessories, and measurement system, among other components. The air pressure can attain 300 kPa, and a general test can be completed in a short time. The apparatus can simply control the drying process and wetting process. The changes in volumetric water content that occur during the drying and wetting processes are shown directly in the SWRC program, in real time. As a case study, we performed an SWCC test of Joomunjin sand (75% relative density) to measure matric suction and volumetric water content during both the drying and wetting processes. The test revealed hysteresis behavior, whereby the water content on the wetting curve is always lower than that on the drying curve for a specific matric suction, during the wetting and drying processes. Based on the test results, SWCCs were estimated using the Brooks and Corey, van Genuchten, and Fredlund and Xing models. The van Genuchten model performed best for the given soil conditions, as it yielded the highest coefficient of determination.

Development of an environment-friendly moving aquatic animal rendering equipment and evaluation of fertilizer value for recycling of fish waste (친환경 이동식 수산생물 폐사체 처리장치 개발 및 재활용을 위한 비료 가치 평가)

  • Kim, Jae-Ok;Kim, Su-Mi;Seo, Jung-Soo;Jee, Bo-Young;Kim, Young-Jae;Kwon, Mun-Gyeong
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.97-101
    • /
    • 2020
  • Although aquaculture production rates grown over the years, aquatic animal diseases occur every year which causes substantial economic losses. When an aquatic animal is infected with an aquatic animal pathogen it is either incinerated or buried according to the aquatic life disease control act. Although these methods prevent the spread of disease, it is not environment friendly. Here, we developed an aquatic animal rendering equipment for disposal of fish waste which is environment-friendly and efficient. Also, fertilizer components of fish waste were evaluated value for recycling. The mobile rendering equipment was designed for field operation and/or high temperature and pressure system, oil and water separator, and shredding drying apparatus. During the experiment (July-2016 to November-2016), a total of 53,824 kg fish waste was collected, and 29,216 kg compost of rendering by-product was made. Also, compost made from viral (Viral hemorrhagic septicemia virus) infected fish did not reflect any detectable pathogen. The concentration of nitrogen, phosphorus, and organic matter in the fish waste compost were 2.17%, 26.98%, and 92.44%, respectively. The results suggest that fish waste used in this study was decomposed efficiently as per the official standard for fertilizer product. This equipment can be useful for efficient inactivation of the aquatic animal pathogenic agents and recycling of the fish waste in an environment-friendly manner.

EEFL using intelligent lighting system control device (EEFL을 이용한 지능형 조명시스템 제어장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.229-234
    • /
    • 2013
  • The purpose of this study is to develop a lighting apparatus of the illuminance and color temperature to maximize the ability of the optimal combination of light sources that can be controlled efficiently control device. Finding people comfortable feeling for indoor lighting that can be used in a variety of color temperature illumination area by combining light sensitivity can be realized. Lighting apparatus for fluorescent lamps with different color temperature of 2000K and 8000K, and by varying the quantity of each of the fluorescent lamps, the illuminance of lighting equipment and color temperature through optical simulations were evaluated. By infrared remote control receiver, divided into 5 types of relaxation, conversation, meeting, hospitality, arts and the lighting environment you want to transfer the PC0 ~ PC4 through the parallel port on the mode selected by the user at the receiving end the DC voltage output. EEFL inverter input DC voltage and the DC input voltage, depending on the level of EEFL dimming value (illuminance and color temperature) lighting environment you want to create change while using a PIR sensor EEFL automatically turn off if people do not have was developed so that the power consumption so you can save.

Design of Tester Apparatus for 48 Channel GM Tube Sensor (48개 채널의 GM Tube 센서 테스터 장치의 설계)

  • Lee, Hee-Yeol;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.310-313
    • /
    • 2016
  • In this paper, we propose the tester apparatus for 48 channel GM Tube sensor. The proposed apparatus can test up to 48 channel GM tube simultaneously to detect the defect and analyze the sensor characteristic. 300-1000V variable high voltage generation circuit is utilized for the apparatus suitable for the sensor characteristic. Thus, the proposed system is useful for various GM Tube sensor characteristic analysis. Multiple sensor testing environment is established for the early detection of the defect and the analysis to reduce the costs for manufacturing and rework. Developed 48 channel GM Tube sensor test is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.