TRIZ(6SC)를 활용한 잉곳 인상모듈 및 실리콘 단결정 잉곳 제조장치의 창의적 설계 (A Study on the Creative Design of Pulling Module for Silicon Ingot and an Apparatus of Manufacturing Silicon Single Crystal Ingot by using TRIZ(6SC))

  • 홍성도;허용정
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.39-43
    • /
    • 2012
  • This paper presents a study on the design of a pulling module for silicon ingot and an apparatus of manufacturing silicon single crystal ingot using the same method. The pulling module is conceptually designed by using TRIZ. Czochralski method(CZ) is representative way to manufacture single crystal ingot for wafers. The seed can be broken by high tension which is caused by large weight of a silicon ingot. The solution of this problem has been derived using 6SC(6 steps creativity)TRIZ. The pulling module is actuated by DC motor and rollers. High tension in the seed is removed by the rotate-elevate motion of rollers in the pulling module. A rubber belt is included in the rotate-elevate mechanism for increasing friction between rollers and silicon ingot.

Preparation and Magnetic Properties of Ba-Ferrite Particles Using the Supercritical Water Crystallization Method

  • Nam, Sung-Chan;Kim, Kun-Joong;Park, Sang-Do
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.433-440
    • /
    • 2000
  • Barium ferrite particles were synthesized from Ba(NO$_3$)$_2$, Fe(NO$_3$)$_3$ and KOH mixed solutions using hydrothermal crystallization in supercritical water. The experimental apparatus for production of barium ferrite is a flow-type apparatus. Fine barium ferrite particles were produced because supercritical water causes the metal hydroxides to be rapidly dehydrated before significant growth takes place. The effects of Fe/Ba ratio and reaction time on the formation, particle size, and magnetic properties of barium ferrite were studied. When Fe/Ba ratio were varied from 0.5 to 12, single-phase barium ferrite powder was only produced in the range of 0.5〈Fe/Ba〈2. Also, with elevating reaction time, the BaO.6Fe$_2$O$_3$ particle size grew smaller. Especially, uniform barium hexaferrite particles of size 100-200nm were obtained at 80sec. In this study, therefore, single-phase barium ferrite particles are highly stable and can be produced continuously in a reaction time of less then 2min.

  • PDF

이상와 누공 1례 (A Case of Piriform Sinus Fistula)

  • 문승일;한정욱;김희규;윤상원
    • 대한기관식도과학회지
    • /
    • 제6권1호
    • /
    • pp.96-101
    • /
    • 2000
  • It is commonly believed that the branchial anomalies are remnants of the branchial apparatus. Third and fourth branchial pouch anomaly is an extremely rare disease involving the branchial apparatus. Virtually mostly reported cases have been on the left side and has been identified in recurrent suppurative thyroiditis, retropharyngeal abscess and repeated episodes of cellulitis, neck swelling, lateral neck fistula. Recently the authors have experienced a case of left piriform sinus fistula accompanied with left suppurative thyroiditis, presumably of fourth branchial origin in a 50-years old male patients, which was successfully treated with coagulation, and so report this case with summary of branchial anomaly by the some review of the literatures.

  • PDF

안주애기박쥐(Vespertillio superans)의 시각에 의한 물체 식별 능력 (Visual Pattern Discrimination in the Oriental Discoloured Bat,Vespertilio superans)

  • 정건상;이주형;박시룔
    • 한국동물학회지
    • /
    • 제33권2호
    • /
    • pp.127-132
    • /
    • 1990
  • 암수 2개체의 안주애기박쥐(Vespertillio superans)를 가지고 시각에 의한 물체 식별 능력의 실험을 실시하였다. 통제된 실험장치(two-chice apparatus)하에 이 박쥐들이 수직막대 모양이 표적과 이것과 면적을 같게한 원형 포적을 식별 가능한지의 결과, 면적이 같고 모양이 다른 두 표적은 전혀 식별하지 못했다. 이에 반하여 면적의 크기가 다소 차이를 갖게한 표적에서는 식별 능력에 있어서 유의 수준의 차이를 보였다. 계속된 실험 결과 같은 두 표적 간에 명암의 정도를 달리하였더니 명암이 근소한 차이(명도 2)를 제외하고는 쉽게 식별이 가능했다.

  • PDF

아세트아미노펜 좌제의 용출과 직장흡수 (Dissoultion and Rectal Absorption of Acetaminophen from Suppositories)

  • 한정선;심창구;김신근
    • 약학회지
    • /
    • 제31권5호
    • /
    • pp.286-295
    • /
    • 1987
  • The relationship between in vitro release and in vivo bioavailability of acetaminophen from suppositories was investigated. Effect of glycyrrhizin on the drug release and rectal absorption in rats was also examined. Suppositories containing 25mg of acetaminophen were prepared with Wecobee FS (fatty base) or PEG (water-soluble base) bases. The release from the suppositories were determined with USP rotating basket dissolution apparatus and with the suppository release tester. The temperature of the dissolution medium was very critical for the dissolution of acetaminophen from Wecobee FS suppositories. The bioavailability of acetaminophen was calculated from the plasma concentration-time curve after rectal administration of the suppositories to the rats. There were no significant differences in AUC following rectal administration of Wecobee FS and PEG suppositories, but the release and absorption from the Wecobee FS suppositories were faster than those from PEG suppositories. The dissolution rate obtained by the suppository release tester was better correlated with in vivo absorption rate constant than that by the USP dissolution apparatus. It suggests that the partitioning between rectal fluid and suppository base is the rate-limiting step in the rectal absorption of acetaminophen from suppositories. Glycyrrhizin was found not to affect in vitro dissolution and rectal absorption of acetaminophen.

  • PDF

투명 재료를 사용하는 광조형 방식 쾌속조형 장비의 성능 비교 시험 (A Benchmark Study on the Stereo-lithography-type Rapid Prototyping Apparatus using Transparent Materials)

  • 김기대;성주형
    • 한국정밀공학회지
    • /
    • 제24권6호
    • /
    • pp.138-145
    • /
    • 2007
  • Among various rapid prototyping processes, stereo-lithography process which can manufacture transparent prototype is known to be the greatest in the form & dimensional accuracy and surface roughness. In this paper, bench mark tests of 4 stereo-lithography-type rapid prototyping apparatus were carried out using transparent materials. The test includes measurement of mechanical properties, form accuracy, building speed and manufacturing cost. It was observed that ViperPRO of 3D systems is advantageous in the mechanical properties and building speed, RM600011 of CMET in sub-milli scale form accuracy and manufacturing cost, and relatively economical Eden500V of Objet is great in tensile strength at room temperature.

Use of the Yeast 1.5-Hybrid System to Detect DNA-Protein-Protein Interaction

  • Kim, Sook-Kyung;Han, Jin-Hee
    • Journal of Microbiology
    • /
    • 제38권2호
    • /
    • pp.113-116
    • /
    • 2000
  • Escherichia coli F plasmid partition apparatus is composed of two trans-acting proteins (SopA and SopB) and one cis-acting DNA sequence (sopC). The SopB-sopC complex has been suggested to serve a centromere-like function through its interaction with chromosomally encoded proteins which remain to be identified. In this paper, we are introducing a new yeast 1.5-hybrid system which assembles the two-hybrid and one-hybrid system as a mean to find and additional component of the F plasmid partition system, interacting with DNA (sopC)-bound SopB protein. The results indicates that this system is a promising one, capable of selecting an interacting component.

  • PDF

세립토의 침식율 측정 (Measurements of Erosion Rate in Fine-Grained Soils)

  • 곽기석;정문경;정하익;우제윤;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.337-342
    • /
    • 2002
  • A new apparatus called the EFA (Erosion Function Apparatus) has been built and tested to measure the erodibility of fine-grained soils. The EFA is a simple test to predict the erosion rate of fine-grained soils along with the corresponding velocity and shear stress. In addition, it is advantageous in predicting the scour rate for actual soil samples from bridge sites. The plot of erosion rate versus shear stress is the result of an EFA test. It Indicates the critical shear stress at which erosion starts and the rate of erosion beyond that shear stress. In order to measure the erodibilities of various soils, 14 Shelby Tube soil samples are collected from the actual bridge sites and tested using the EFA. The results of the EFA tests which are the relationships between erosion rates and shear stresses are presented in this paper and research continues to develop the correlation between the erosion function and the soil properties.

  • PDF

전파 뇌충격전압 측정용 쉴드저항분압기의 직각파 특성에 관한 연구 (A Study on the step response characteristics in shielded resistor divider for full lightning impulse voltage)

  • 김익수;이형호;조정수;박정후
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.283-288
    • /
    • 1996
  • This paper presents the development technology of standard shielded resistor divider for full lightning impulse voltage. The ability of large-capacity power apparatus to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently international standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisons have already completed worldwide, i.e. Europe, Japan, America etc., In this viewpoint, we have also investigated the step response of the standard shielded resistor divider, which satisfies the IEC recommendation.

  • PDF

강판의 곡가공 자동화를 위한 수치제어 시스템 (Numerical Control System for the Automation of Steel Plate Forming)

  • 이주성;신성민
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.318-322
    • /
    • 2002
  • In this paper the automatic plate forming system developed by the present research group is introduced, which would be helpful for other researchers. The present system consists of three parts : heating line information generation software, automatic heating apparatus and numerical control system. The numerical control system developed by the present authors is detailed. Performance test for the developed system has been carried out and good results has been obtained. As an extension of the present study, the present automatic plate fanning system will be applied to surfaces found in ship and offshore structure.