• Title/Summary/Keyword: apparatus

Search Result 4,312, Processing Time 0.03 seconds

Study on the parameter estimation of short-circuit generator (단락발전기 파라미터 추정에 대한 고찰)

  • Kim, Sun-Ho;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.866-867
    • /
    • 2008
  • Among many tests to verify the characteristics of power system apparatus, the short circuit test is performed to verify the performance characteristics of the apparatus under the short-circuited power system. The verification of the short-circuit performance is inevitable for the reliability of power system and the safety of the operator around. The short circuit performance test requires the suitable power source and Korea Electrotechnology Research Institute has 4000 MVA, 500 MVA short circuit generators for the short circuit performance test. This paper will study on the parameters of short-circuit generator and the estimation of them.

  • PDF

Heat Transfer Performance of Plate Type Absorber with Surfactant

  • Yoon, Jung-In;M. M. A. Sarker;Moon, Choon-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.243-251
    • /
    • 2004
  • Absorption chiller/heater can utilize the unused energy of the daily life waste heat, the industry waste heat. the solar energy and the earth energy. These can contribute to energy savings. But the absorption chiller/heater has a demerit that the size of absorption chiller/heater is larger than that of the vapor compression type based on same capacity. In this study. the experimental apparatus of an absorber is manufactured as a plate. which is newly applied in an absorber. The experimental apparatus is composed of a plate type absorber. which can increase the heat exchange area per unit volume and thus facilitating to deeply investigate more detail features instead of that done by the existing type. i.e.. horizontal tube bundle type. The characteristics of heat transfer and refrigeration capacity are studied experimentally. The absorption enhancement by using surfactant is closely examined through the experiment and comparative figures are presented in quantitative and qualitative analysis.

Automatic Measurement of Microbial Growth in Snake-Flask Culture using an Economic and Automated flow injection Analysis Apparatus (경제적인 자동화 FIA 장치를 이용한 진탕플라스크 배양액의 미생물 증식도의 자동측정)

  • 이형춘
    • KSBB Journal
    • /
    • v.19 no.3
    • /
    • pp.241-244
    • /
    • 2004
  • An automated flow injection analysis apparatus manufactured economically was used in the automatic measurement of E. col growth in shake-flask culture of nutrient broth. The detailed measurement of whole growth was possible at intervals of 10 minutes by the automatic measurement system which adopted the sterilized nutrient broth as a carrier solution. Using distilled water as a carrier solution showed less accurate results than nutrient broth.

Connection Apparatus using Coupling Device and Linking Method for Reinforcing Bar (철근연결구를 이용한 철근이음장치(LK-DK) 개발에 관한 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Park, Seung-Hwan;Ann, Tae-Han;Choe, Min-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.175-176
    • /
    • 2012
  • In this study, coupler on the safety of meeting the requirements and construction and economy to satisfy the number of parts to minimize an LK-DK coupler has been developed, affordability existing reinforcing bar joint, welded joint, mechanical joints, compared with a favorable one to the understanding, and also facilitate the construction and logistics, etc. I've found that there is no additional pay because the amount of product performance through the tensile test after test, if commercialization is expected to be greater ramifications.

  • PDF

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.

Improvement of triggering system of impulse voltage generator for Extra high-voltage (충격전압발생기 트리거 시동장치 성능개선)

  • Heo, J.C.;Park, S.J.;Moon, I.W.;Park, J.W.;Oh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1704-1706
    • /
    • 2002
  • With increasement of use in electricity energy, quality of electric apparatus has been recognized as important factor in distribution and transmission line. Especially In laboratories, lightning and switching impulse performances of electric apparatus have been carrying out by impulse voltage generator (IVG), simulated into lightning and switching surge circuit. In this paper, we describe triggering system of impulse voltage generator(IVG) for extra high voltage, which has been newly designed.

  • PDF

Heating Dryness Experiment and Characteristic of red pepper by Induction Heating apparatus (유도가열장치에 의한 고추의 가열건조 실험 및 특성)

  • Han, K.H.;Baek, J.W.;Joe, K.Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.260-262
    • /
    • 2002
  • The scope of applications industrial or household manufactures, is on the increase. In this study, it applies a principle of induction heating to food dryness for preservation of food. And it applies indirect heating process using overheating steam, which analyzes thermal characteristic of heating apparatus depending on its construction. It was verified that application of proposed process was appropriate by drying test of food.

  • PDF

LMI-Based Controller Design of Pneumatic Cylinder (LMI를 이용한 공기압 실린더의 상태제어기 설계)

  • Jang, J.S.;Ji, J.W.;Kim, Y.B.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Pneumatic driving systems have hard non-linear characteristic and large friction force compared with driving power. Hence, it cannot be robust against parameter uncertainties, modelling error, disturbance and noise. In this study, we apply a mixed $H_2/H_{\infty}$ control to the generalized plant for a pneumatic driving apparatus system including parameter uncertainty and disturbance. In order to design the $H_2/H_{\infty}$ controller, we use the LMI technique. To evaluate control performance and robust stability of the designed controller, we compare it with a conventional controller such as PVA(Position-Velocity-Acceleration state controller) using the simulation results. As a result, it can be known that designed controller shows better robust stability than the conventional controller.

  • PDF

A Solution to Large Strain Resonant Column and Torsional Shear Tests Apparatus (대변형율 시험을 위한 공진주/비틂전단 시험기의 해결방안)

  • Bae, Yoon-Shin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3C
    • /
    • pp.103-108
    • /
    • 2011
  • In this study, the limitations of large strain resonant column and torsional shear tests apparatus are described and solutions to the limitations are also described. The limitations are rotational distance, limited torque, and measurable deformation system, respectively. To resolve the rotational distance, the bottom platen was modified. And the four-armed drive plate was modified into eight-armed drive plate and the drive coil connection was changed to obtain powerful torque.

The Plastic -film -covered Hill Planter

  • Jun, Zhang-Xue;YangYin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1041-1044
    • /
    • 1996
  • The plastic-film-covered hill planter is a new-type seeding machine, including tow types which are mounted by 11kw and 40 kw tractors. It is made up of fertilizing , plastic-film covering perforating film and hole seeding, soil sealing apparatus, and can work at 5-7kw/h. The plastic-film covering and seeding of cotton, corn and soybean can all use this machine. The plastic-film-covered hill planter is mainly composed of plastic film covering unit, drum-type hill-drop unit and furrow coverer, some other types are also equipped with fertilizer drill unit. It can do combined work of covering plastic film , sowing , plastic film perforating , soil covering at one time, and it is suitable to the covering plastic film as well as planting of the grandulated crops, such as cotton , corn, soybean and so on.

  • PDF