• Title/Summary/Keyword: apparatus

Search Result 4,308, Processing Time 0.036 seconds

Development of persimmon harvest apparatus -Development of detachment device (감 수확기구 개발(1) - 탈과장치 개발 -)

  • Woo, D.G.;Kim, T.H.
    • Current Research on Agriculture and Life Sciences
    • /
    • v.27
    • /
    • pp.1-6
    • /
    • 2009
  • Persimmon occupied the second largest cultivation area next to apple among the fruits in Korea. Since 70 % of its cultivating field is located at slope, the efficiency of its harvesting operation is very low. Also, the traditional persimmon harvest apparatus does not seem to be efficient to use due to a structural problem. In this paper, the author has analyzed the physical properties of persimmon friut-stem system and compared detachment force with developed persimmon harvest apparatus and traditional persimmon harvest apparatus in order to solve the problems mentioned above. The results of the research are summarized as follows : 1. The weight of the persimmon is shown as 157 g on average, the lengths of stem's major axis and minor axis is shown as 4.6 mm and 3.7 mm on average, respectively, sectional area of stem is shown as $13.9mm^2$ on average and the stem length is shown as 13.6 mm on average. 2 In case of the traditional persimmon harvest apparatus, the detachment force needed when a persimmon was detached from its stem was shown as 86.3 N on average. 3. In case of the developed persimmon harvest apparatus, detachment force needed when a persimmon was detached from its stem was shown as 72.6 N on average.

  • PDF

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Economic Analysis of Korean-type Mobile Carbonization Apparatus for the Field Utilization of Logging Residues (산지폐잔재의 현지 활용을 위한 한국형 조립식 탄화장치의 경제성분석)

  • Chang, Cheol-Su
    • Journal of Forest and Environmental Science
    • /
    • v.23 no.1
    • /
    • pp.11-19
    • /
    • 2007
  • This study was designed to analyze the economic efficiency that is needed to develop and make practical application of a mobile carbonization apparatus, which are able to make wood charcoals and pyroligneous liquid at the logging field with debris. B/C ratio was employed to make an economic analysis, and sensitivity analysis with respect to change in price and interest rates also was made. Cylindrical type is the proper type for the mobile carbonization apparatus, when important factors such as handling capacity, a carbonization time, quality of products and assembling ability were considered. It weighs 400 kg, and a three-step fold-up equipment. The size of 2 (diameter) by 2.4 m (height) carbonization equipment required 1,500 kg wood debris per batch. A forty-eight to fifty-two carbonization time produced 300 kg of wood charcoal and $45{\ell}$ of pyroligneous liquid. The average life span of the apparatus was 5 years. If the private enterprise operated 100 batch, 80 batch, and 70 batch with one apparatus, the B/C ratio of them was greater than 1, indicating that the production is economically feasible. The period to achieve a break-even point required to be 4 years in case of 100 and 80 batches to 5 years in case of 70 batch. But the private enterprises should operate at least two apparatus for the profits. Also, if the production was to be profitable, the prices of wood charcoals and pyroligneous liquid should be at least 750 won per kg and 700 won per liter.

  • PDF

Evaluation of Dynamic Properties of Crushed Stones Used as Reinforced Trackbed Foundation Materials Using Midsize Resonant Column Test apparatus (중형 공진주 시험기를 이용한 국내 쇄석 강화노반재료의 동적특성 평가)

  • Lim, Yujin;Lee, SeongHyeok;Lee, Jinwoog;Cho, Hojin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.476-484
    • /
    • 2012
  • In this study, a mid-size RC test apparatus equipped with analyzing program is developed that can test samples up to D=10cm diameter and H=20cm height which is larger than usual samples of D=5cm and H=10cm used mostly in practice. Thus, crushed stones with larger grains up to 38mm in diameter used mostly in Korea as reinforced trackbed materials in track construction could be considered effectively than conventionally used RC apparatus for evaluation of the dynamic properties of the materials by using the newly developed RC apparatus. The RC test apparatus was designed and assembled based on the concept of fixed-free fixity conditions and driving mechanism proposed by Stokoe. Using the developed RC test apparatus, three types of representative crushed reinforced trackbed materials were tested in order to get the dynamic properties of the materials such as $G/G_{max}$ reduction curves and damping ratio D. For comparison purpose, a small RC test apparatus has been used to test the same materials.

Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus (전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

The Development and Evaluation of Sidestream Smoke Collecting Apparatus Compatible for Linear Smoking Machine (다채널 선형자동흡연장치 부착형 부류연 포집장치의 개발과 평가)

  • Kim Hyo-Keum;Hwang Keon- Jung;Ji Sang-Un;Lee John-Tae;Rhee Moon-Soo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.120-126
    • /
    • 2005
  • The Fishtail Chimney system mounted on 1 channel smoking machine is not appropriate for the routine analysis of sidestream smoke, because of its low repeatability and very long time required for smoke collection. To overcome this inconvenience, we developed a new sidestream smoke collecting apparatus compatible for 8 channel linear smoking machine. An electric motor driven stroke and automatic control system were adopted in this device to maximize convenience and efficiency of its operation. Also, we carried out the international collaborative study on monitoring sidestream smoke analysis to test the performance of this system. From the statistical analysis of the data obtained in our laboratory and other participating labs, it has been indicated that the newly developed sidestream smoke collection apparatus could be applicable to the routine analysis of sidestream smoke.