• Title/Summary/Keyword: apical size

Search Result 167, Processing Time 0.029 seconds

Cemento-osseous dysplasia: clinical presentation and symptoms

  • Nam, Inhye;Ryu, Jihye;Shin, Sang-Hun;Kim, Yong-Deok;Lee, Jae-Yeol
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.2
    • /
    • pp.79-84
    • /
    • 2022
  • Objectives: The purpose of this study was to evaluate risk factors and symptoms in cemento-osseous dysplasia (COD) patients. Materials and Methods: In this study, 62 patients who were diagnosed histologically with COD were investigated from 2010 to 2020 at the author's institution. We compared clinical and radiological characteristics of symptomatic and asymptomatic patients. The factors were sex, age, lesion size, site, radiologic stage of lesion, apical involvement, sign of infection, and history of tooth extraction. Statistical analysis was performed using Fisher's exact test and the chi-square test. Results: COD was more prevalent in female patients. With the exception of three cases, all were focal COD. The majority of patients presented with symptoms when the lesion was smaller than 1.5 cm in size. Symptoms were observed when the apex of the tooth was included in the lesion or there was a local infection around the lesion. The history of tooth extraction and previous endodontic treatment were evaluated, and history was not a significant predictor for the onset of symptoms. Conclusion: In this study, risk factors associated with symptomatic patients were size of lesion, apical involvement, and local infection.

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

THE SEALING ABILITY OF OBTURATION TECHNIQUES IN OPEN APEX (개방 근첨 치아의 근관 충전방법에 따른 치근단 폐쇄효과에 관한 연구)

  • So, Hyun;Choi, Ho-Young;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.435-445
    • /
    • 2000
  • The purpose of this study was to compare the leakage of four different obturation techniques in conjunction with immediate apical barrier of ${\beta}$-tricalcium phosphate(TCP) in teeth with open apex. Eighty single-rooted human premolar teeth were prepared and sectioned horizontally, so maximum diameter in apex was 4mm. Apical defects that were similar to open apex, were created with #1/2 round bur and SF104R bur. The apical foramen were opened to a size 80 file extended 3mm beyond the apex. The teeth were placed into the oasis block soaked saline to simulate periapical tissue often associated with pulpless teeth and received apical barriers consisting of TCP followed by obturation using lateral condensation technique, vertical condensation technique, continuous wave technique and thermoplasticized gutta-percha injection technique. Two unobturated teeth served as positive and negative controls. Teeth were immersed in resorcinol-formaldehyde resin for S days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then sectioned horizontally at 1.5mm(level 1), 2.5mm(level 2) and 3.5mm(level 3) from the apex, and examined under a stereomicroscope at ${\times}40$ magnification. The photographs were taken at ${\times}40$ magnification of the filling in each level and scanned. The leakage length in tooth/resin interface was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the leakage length of canal wall infiltrated with resin to the total length of the canal and was analyzed statistically(One-way ANOVA and Scheffe test). The result were as follows : 1. At the level 1, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), and the most leakage in the continuous wave technique group(group 3). There was statistically significant difference between the thermoplasticized gutta-percha injection technique group and the continuous wave technique group(p<0.05). 3. At the level 3, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there were no statistically significant differences between other groups(p>0.05). These results suggest that thermoplasticized gutta-percha injection technique which had 1mm apical gutta-percha matrix after the formation of TCP apical barrier, can demonstrate favorable apical sealing.

  • PDF

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

EVALUATION OF ROOT CANAL TRANSPORTATION AND REMAINING DENTIN/CEMENTUM THICKNESS FOLLOWING HAND AND ULTRASONIC INSTRUMENTATION (근관형성 방법에 따른 근관변위와 잔존치질의 두께에 관한 연구)

  • Seo, Byoung-Kon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.399-412
    • /
    • 1992
  • The purpose of this study was to evaluate the root canal transportation and remaining dentin / cementum thickness after using hand and ultrasonic instrumentation in the curved mesial root canals of extracted human mandibular molars. Fourty - six clear polyether blocks were made and randomly divided into two groups: hand instrumentation group with K - Flex files and ultrasonic instrumentation group with Suprasson SP unit. All root canals were instrumented to a size corresponding to a # 30 K - Flex file 1mm short from the radiographic apex. The roots were then sectioned perpendicular to the long axis so the apical and middle third could be evaluated with the Zoom stereomicroscope. The results were as follows : 1. In the total amount of removed dentin at middle third level, there was not significant difference between the hand instrumentation and ultrasonic instrumentation (P>0.05). 2. In the total amount of removed dentin at apical third level, there was more removed by the ultrasonic instrumentation than hand instrumentation(P<0.005). 3. In the transportation width, there was not significant difference between the two groups at both sectioned levels(P>0.05). 4. It was suggested that the canal was transported distally at middle third level and mesially at apical third level by booth techniques.

  • PDF

AN EXPERIMENTAL STUDY ON THE FLOW OF CANAL SEALER BY MEANS OF LENTULO (근관내(根管內) 근관충전제(根管充塡劑)의 유입성(流入性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Myong-Chong
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.34-38
    • /
    • 1975
  • Artificial canals were prepared by means of engine reamer on the slab which was made of clear acrylic resin. The shape of this canal is similar to the natural canal, the size is almost same as Kerr File No. 70, and the length is about 20mm. Sealer, Zine oxide eugenol mixture was prepared as matched to spatula test. Lentulo filler was inserted as deep as middle portion and apical one-third portion of the canal and the dental engine was driven in the speed of 1,000 and 3,000 r.p.m. in 30 seconds and 60 seconds with feeding of the sealer. The author measured the excess flow of the canal sealer from Lentulo end. Following are the results obtained from this study. 1. Lentulo insertion at the middle portion 1,000 r.p.m. in 30 seconds case: 0.21mm Same as above in 60 seconds: 0.20mm 2. Lentulo insertion at apical-thirds. 1,000 r.p.m. in 30 seconds: 0.22mm. Same as above in 60 seconds: 0.20mm. 3. Lentulo insertion at middle portion. 3,000 r.p.m. in 30 seconds: 0.14mm Same as above in 60 seconds: 0.25mm. 4. Lentulo insertion at apical-thirds, 3,000 r.p.m. in 30 seconds: 0.11mm Same as above in 60 seconds: 0.27mm.

  • PDF

Efficacy of reciprocating and rotary retreatment nickel-titanium file systems for removing filling materials with a complementary cleaning method in oval canals

  • Said Dhaimy;Hyeon-Cheol Kim;Lamyae Bedida;Imane Benkiran
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.13.1-13.9
    • /
    • 2021
  • Objectives: This study aimed to evaluate and compare the efficacy of the S1 reciprocating system and the D-Race retreatment rotary system for filling material removal and the apical extrusion of debris. Materials and Methods: Sixty-four freshly extracted maxillary canines were shaped with size 10 and size 15 K-files, instrumented using ProTaper Gold under irrigation with 2.5% sodium hypochlorite (NaOCl), obturated according to the principle of thermo-mechanical condensation with gutta-percha and zinc oxide eugenol sealer, and allowed to set for 3 weeks at 37℃. Subsequently, the teeth were divided into a control group (n = 4), the D-Race rotary instrument group (n = 30), and the S1 reciprocating instrument group (n = 30). After classical retreatment, the canals were subjected to a complementary approach with the XP-Endo Shaper. Desocclusol was used as a solvent, and irrigation with 2.5% NaOCl was performed. Each group was divided into subgroups according to the timing of radiographic readings. The images were imported into a software program to measure the remaining filling material, the apical extrusion, and the root canal space. The data were statistically analyzed using the Z-test and JASP graphics software. Results: No significant differences were found between the D-Race and S1 groups for primary retreatment; however, using a complementary cleaning method increased the removal of remnant filling (p < 0.05). Conclusions: Classical removal of canal filling material may not be sufficient for root canal disinfection, although a complementary finishing approach improved the results. Nevertheless, all systems left some debris and caused apical extrusion.

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

  • Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.22.1-22.10
    • /
    • 2020
  • Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.