• Title/Summary/Keyword: aperture focusing

Search Result 58, Processing Time 0.02 seconds

Improvement of Signal to Noise Ratio by Synthetic Aperture Focusing Technique in Ultrasonic Testing (집속 신호 합성 기법에 의한 초음파 탐상 신호 개선)

  • Lee, S.L.;Chang, K.O.;Kim, B.C.;Kim, G.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 1998
  • Nondestructive method can include both testing itself and analysis or evaluation of the testing results. Although vast amount of testing can be accomplished in a fairly short amount of time due to the advancement of electronic technology. it is really difficult matter to identify whether the indication found during testing corresponds to be a real defect. Thus, in ultrasonic testing, advanced digital signal processing techniques have been widely studied in order to identify the shape of the defect during testing, and one of the signal processing techniques, synthetic aperture focusing technique(SAFT) was tried for holes machined in carbon steel plate in this study. Result showed that signal to noise ratio has been improved considerably compared to the result from original RF signals.

  • PDF

Imaging of Harmonic Wave Generated by Contact Acoustic Nonlinearity in Obliquely Incident Ultrasonic Wave (경사입사 초음파에서 계면 접촉 음향 비선형성에 의해 발생한 고조파의 영상화)

  • Yun, Dong-Seok;Choi, Sung-Ho;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.362-368
    • /
    • 2012
  • The objective of this study is to image the harmonic wave generated by contact acoustic nonlinearity in obliquely incident ultrasonic wave for early detection of closed cracks. A closed crack has been simulated by contacting two aluminum block specimens producing solid-solid contact interfaces and then acoustic nonlinearity has been imaged with contact pressure. Sampling phased array(SPA) and synthetic aperture focusing technique(SAFT) are used for imaging techniques. The amplitude of the fundamental frequency decreased with appling pressure. But, the amplitude of second harmonic increased with pressure and was a maximum amplitude at the simulation point of closed crack. Then, the amplitude of second harmonic decreased. As a result, harmonic imaging of contact acoustic nonlinearity is possible and it is expected to be apply for early detection of initial cracks.

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

Development and Distribution of an Educational Synthetic Aperture Radar(eSAR) Processor (교육용 합성구경레이더 프로세서(eSAR Processor)의 개발과 공개)

  • Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.2
    • /
    • pp.163-171
    • /
    • 2005
  • I have developed a processor for synthetic aperture radar (SAR) raw data compression using range-doppler algorithm for educational purpose. The program realized a generic SAR focusing algorithm so that it can deal with any SAR system if the specification is known. It can run efficiently on a low-cost computer by selecting minimum size out of a whole dataset, and can produce intermediate images during the process. Especially, the program is designed for educational purpose in such a way that Doppler centroid and azimuth ambiguity can be determined graphically by the user. By distributing the source code and the algorithm to public, I intend to maximize the educational effect on understanding and utilizing SAR data. This paper introduces the principle of SAR focusing algorithm embedded on the eSAR processor and shows an example of data processing using ERS-1 raw data.

Electron Beam Properties of Microcolumn Based on the Structure of Electrostatic Lens Apertures (전자 렌즈 Aperture 구조에 따른 마이크로칼럼의 전자빔 특성)

  • Choi, Sang-Kuk;Yi, Cheon-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.428-432
    • /
    • 2005
  • Microlens precisely fabricated by MEMS process, is a key component of the Microcolumn, Since, miniaturization can reduces aberrations, microcolumn is expected to have better performance than conventional columns. Depending on the fabrication techniques, the sectional view of micro lens has different shape. In the paper, the effect of the sectional shape of extractor lens and limiting aperture on the focusing property of microcolumns have been studied.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

REFOCUSING FOR ON-ORBIT MTF COMPENSATION OF REMOTE SENSING CAMERA

  • Jang Hong-Sul;Jeong Dae-Jun;Lee Seunghoon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.601-603
    • /
    • 2005
  • Refocusing methods are used to compensate optical performance degradation of high resolution satellite camera during on-orbit operation. Due to mechanical vibration during launch and thermal vacuum environment of space where camera is exposed, the alignment of optical system may have error. The focusing error is dominant of misalignment and caused by the de-space error of secondary mirror of catoptric camera, which is most sensitive to vibration and space environment. The high resolution camera of SPOT, Pleiades and KOMPSAT2 have refocusing device to adjust focusing during orbital operation while QuickBird of US does not use on orbit refocusing method. For the Korsch type optical configuration which is preferred for large aperture space remote sensing camera, secondary mirror and folding mirror are available as refocusing element.

  • PDF

Requirements of processing parameters for Multi-Satellites SAR Data Focusing Software

  • Kwak Sunghee;Kim Kwang Yong;Lee Young-Ran;Shin Dongseok;Jeong Soo;Kim Kyung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.401-404
    • /
    • 2004
  • SAR (Synthetic Aperture Radar) signal data need a focusing procedure to make the information available to the user. In recent SAR systems, various sensing modes and mission operations are applied to acquire high-resolution SAR images. Therefore, in order to develop generalized focusing software for multi-satellites, a regularized parameter configuration that sufficiently represents sensor and platform characteristics of the SAR system is required. The objective of this paper is to introduce the consideration of parameter definition for developing a generalized SAR processor and to discuss the flexibility and extensibility of defined parameters. The proposed parameter configuration can be applied to a SAR processor. Experiments based on real data will show the suitability of the suggested processing parameters.

  • PDF

A Feasibility Study on the Cold Hollow Cathode Gas Ion Source for Multi-Aperture Focused Ion Beam System (다개구 이온빔 가공장치용 냉음극 방식의 가스 이온원의 가능성 평가에 관한 연구)

  • Choi, Sung-Chang;Kang, In-Cheol;Han, Jae-Kil;Kim, Tae-Gon;Min, Byung-Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.383-388
    • /
    • 2011
  • The cold hollow cathode gas ion source is under development for multi aperture focused ion beam (FIB) system. In this paper, we describe the cold hollow cathode ion source design and the general ion source performance using Ar gas. The glow discharge characteristics and the ion beam current density at various operation conditions are investigated. This ion source can generate maximum ion beam current density of approximately 120 mA/$cm^2$ at ion beam potential of 10 kV. In order to effectively transport the energetic ions generated from the ion source to the multi-aperture focused ion beam(FIB) system, the einzel lens system for ion beam focusing is designed and evaluated. The ions ejected from the ion source can be forced to move near parallel to the beam axis by adjusting the potentials of the einzel lenses.

Target-to-Clutter Ratio Enhancement of Images in Through-the-Wall Radar Using a Radiation Pattern-Based Delayed-Sum Algorithm

  • Lim, Youngjoon;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.405-410
    • /
    • 2014
  • In this paper, we compare the quality of images reconstructed by a conventional delayed-sum (DS) algorithm and radiation pattern-based DS algorithm. In order to evaluate the quality of images, we apply the target-to-clutter ratio (TCR), which is commonly used in synthetic aperture radar (SAR) image assessment. The radiation pattern-based DS algorithm enhances the TCR of the image by focusing the target signals and preventing contamination of the radar scene. We first consider synthetic data obtained through GprMax2D/3D, a finite-difference time-domain (FDTD) forward solver. Experimental data of a 2-GHz bandwidth stepped-frequency signal are collected using a vector network analyzer (VNA) in an anechoic chamber setup. The radiation pattern-based DS algorithm shows a 6.7-dB higher TCR compared to the conventional DS algorithm.