• Title/Summary/Keyword: apartment housing

Search Result 1,822, Processing Time 0.023 seconds

Remodeling of Stairways Apartment House (편복도형 아파트 주거환경개선을 위한 기초적 연구 - 단위주호 중심으로-)

  • 강혜진;윤재은
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.127-130
    • /
    • 2003
  • In the Korean construction market the housing exceeds more than 60% among the entire objects for remodelling. And among the 50% of the common residence that needs remodelling, half of them are common houses with hallways. In respect of remodelling the common houses with hallways to those with stairways, This investigation aims at not only increasing the area by simply enlarging it, but also elevating the residential value by improving the environment based on the study of the existing plane with stairways. In order to do so, the satisfaction rate after living in common residence either with stairways or with hallways according to size (10, 20, 30 pyong), public space and interior environment is investigated through questionnaire. Therefore, this study tries to discover and analyze the positive and negative aspects of common residence with hallways.

  • PDF

A Comparative Study on Residential Interior Spatial Structure According to the Size of Housing Units-Multi-Dimentional Analysis for Household Activities (주거평형 규모에 따른 작업공간 구성체게에 대한 비교연구)

  • 이연숙;장순원;안지영
    • Korean Institute of Interior Design Journal
    • /
    • no.2
    • /
    • pp.17-21
    • /
    • 1994
  • The purpose of this study was to compare the spatial structures for household activities according to the house size. multi-Dimentional Scaling analysis was done, using questinonaire data from 349 middle income housewives living in apartment in the area of Captital region. This was an extended article of previous one. In case of house whose size was less than 20 Pyung, washing cloth and bathing behavior took place in the same place whereas in other house size, bathing behavior was incoperated into various behaviors usually shown in the bedroom. The ideal structure in the house of 20 Pyung's showed home office space closer to the bedroom area whereas in others it appeared independently.

  • PDF

The Optimization Method of Symmetrical Building Plan Using Point Group Theory (포인트그룹 이론을 이용한 대칭적 건물 평면형태의 최적대안 결정방안)

  • 진경일
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.75-82
    • /
    • 2003
  • The symmetry is general geometric design principal in contemporary architecture shape. But, Symmetry sometimes easily causes unreasonable design. In some reason, two of symmetric units in the apartment, one side of unit have very reasonable plan and arrangement but opposite side unit nay not. For example, if the kitchen on right unit had right-handed arrangement, the symmetrical other would have left-handed kitchen arrangement. In addition to this, if each house unit has the same plan but different direction, each unit has different usage or affects the residents' life pattern. Nevertheless, Architects use only one unit plan to design public housing development by using symmetric operator (mirror, proper rotation, inversion center) at their option. This study suggests that using group theory and mathematical matrix rather than designer's discretion can solve this symmetry problem clearly. And, this study analysis the merits and demerits between each symmetrical pair of unit plan shapes by using mathematical point group theory and matrix.

A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings (바닥마감재에 의한 바닥충격음 차음특성 연구)

  • Gi, No-Gab;Kwon, Hyun-Jong;Song, Min-Jeong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.682-686
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound Insulation performance of materials and elements used in building is falling down as they become thicker and lighter. Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. This paper aims to experiment the sound insulation characteristics of floor coverings as their types and to analyse their noise reduction effect.

  • PDF

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

A Case Study on Reason Analysis for Schedule Delay of Apartment House (공동주택의 공기지연 원인분석 사레 연구)

  • Park, Chang-Wook;Yun, Seok-Heon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.1
    • /
    • pp.89-94
    • /
    • 2009
  • A study was performed the analysis for the schedule delay of the public housing. To perform this study, the first study existing research literature on the cause of the schedule delay was considered. The based on existing study, this study selected the cause of schedule delay. For check of the schedule delay, this study was compared the monthly schedule and the work diary. Survey was conducted for using the selected cause of schedule delay. And the importance was calculated for using the AHP method. In a case site, the cause of the schedule delay was analyzed. The last, the delay cause was presented the map of cause of effect the based on the delay cause of a case site.

A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab (바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구)

  • Song, Pil-Dong;Park, Myung-Kil;Ham, Jin-Sik
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF

Comparison of Thermal Environment in Livingroom between Korea and Japan (바닥 난방을 사용하는 주택내 거실 온열 환경의 한일비교)

  • Lee, Min-Jung;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.47-51
    • /
    • 2003
  • In this paper, we compared the thermal environment in the livingroom with panel heating system of Korea and Japan. The houses are two apartments and two single houses in Korea, and two apartments in Japan. The outdoor temperatures, indoor air temperatures, surface temperatures on floor and humidities were measured. The survey to the residents and recording of operation were also collected. The results were as follows.1. The Korean houses are warmer and drier(approximately 23$^{\circ}$C, 38%) than those of Japan.(approximately 20$^{\circ}$C, 57%). And indoor temperaures of Korean apartment are stabie. 2.The residents in Japan put on and off the switches of the heating system frequently.

  • PDF

A Study on Thermal Environment and Residents' Usage Behaviors of Cooling Devices in Apartments' Living Rooms (여름철 집합주택의 거실 온열 환경의 측정 및 거주자의 냉방기 사용행위에 관한 연구)

  • Bae, Nu-Ri;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.323-328
    • /
    • 2004
  • This study measured the thermal environment and residents' cooling behavior of the apartments' living rooms in summer in Seoul. The purpose of this study is to find out the present thermal environment of the living rooms and to find out the target figure of passive cooling system. The surveys and measurements took place in six apartments of Seoul for 60days(2004. 7. 3${\sim}$2004. 8. 31). The result were summarized as follows; The thermal environment of apartments' living rooms were almost neutral, and residents felt a little uncomfortable. Residents turned on the air conditioner at $27.31^{\circ}C$ of indoor temperature, and $28.89^{\circ}C$ of SET*. Therefore, cooling critical temperature of the passive cooling system can be figured out from this result.

  • PDF

An Analysis on the Concept of Boundary in Spatial Composition of the Residential Apartments (경계개념에 의한 아파트 공간구성의 분석 연구)

  • Lee, You-Yeong;Lee, Youn-Jung;Jeong, Jun-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.311-314
    • /
    • 2008
  • Assuming that while the Confucian idea-based awareness of boundary appeared to have a distinct effect on traditional residential spaces the awareness of an individualized nuclear family-oriented boundary deviated from authoritarianism has been recently shown in the modern residential spaces, this study was conducted to clarify what the modern people's awareness of boundary influences individual residential spaces and how the boundary is structured. This study was carried out by examining prior studies on the concepts of boundary and analysing the planes of residential apartments as a typical modern residential space, based on the comparison of traditional and modern residential spaces. It was shown, then, that the awareness of boundary in the modern residential space appeared to be structured in the residential apartment space according to the change in the social position and role of family members, unlike the spatial division of the traditional residential spaces based on the social class and sex.

  • PDF