• Title/Summary/Keyword: apartment houses

Search Result 659, Processing Time 0.038 seconds

The Characteristics of Population and Family Composition by the Unit Type in Apartment Houses (아파트단지의 단위세대별 인구 및 가족형구성에 관한 분석)

  • Chung Sa-Hee;Choi Seung Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.97-104
    • /
    • 2005
  • The purpose of this study is to understand changes of the population and family composition in apartment houses. The main contents of this study is to find the way of housing planning through the analysis of the population and family composition by the unit types. The population and family composition were studied by computer data base program to 11,000 residents of selection 4 apartments houses. The structure of the family types proved to be constant by the result of analyzing the 10 family types. If the family types of certain resident's groups are given, this study will be able to estimate population structure to them. The transition of the population and the family composition changes to the unit types proved to be constant by the time. The distribution of manhood and matured children is tend to change according to how large the size of house is, and to change the structure of family composition.

A Research on the Actual Condition of Living in the Three Generation Sharing Apartment Houses -A Case of Sang-Gye Area- (3대 동거형 아파트의 입주후 실태분석 -상계지역의 경우-)

  • 신경주
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.3
    • /
    • pp.89-102
    • /
    • 1989
  • The purpose of this survey was to find out the actual conditions of living and housing needs of three generation family in the sharing apartment houses in Sang-Gye area. 1. General family type was one which is living with single parent (female), middle-aged couple and their children togeter. 2. Their main mobility to move in this houses was because of the special design of sharing apartment houses. 3. Most of actual dwelling activities of old parents and middle aged couple were performed in condition of space-integration except a few activities. 4. The "Space-compromise type" was proved as the most ideal type of three generation sharing house in our country. In which, private spaces (such as bed rooms and bath rooms) are planned to be used seperately, public spaces (such as living room and dining room) together. 5. It would be better if massionette type was taken in the case of more than 30 pyung (net area).net area).

  • PDF

A Study of the Using Pattern of the Bathroom Shown in the Rural Apartment Houses (농촌공동주택(農村共同住宅) 욕실공간(浴室空間)의 이용(利用) 행태(行態) 연구(硏究))

  • Cho, Il-Howan;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.1
    • /
    • pp.129-138
    • /
    • 1999
  • The aim of this study is to obtain new design factors which can be applied to the constructing design of bathrooms. This study was especially focused on the using patterns of the bathrooms of the rural apartment houses in Chungbuk Province which have been constructed by the public program to improve old farm houses. To carry out this study, field study, questionnaire survey and personal interview have been made. The results are as follows. 1) It is essential to lay out a bathtub, because farmers need to relieve their fatigue caused by manual labor, and mostly they don't find a bathhouse in the neighborhood. 2) With the drainage way, it is necessary to equip an apparatus to collect and remove the fallen hair and garbage which usually stop up the beak. 3) Considering the using patterns of the bathrooms as the place of washing one's face, foot, hair and clothes, one more hydrant is needed in the bathroom besides the two hydrants in the washstand and bathtub.

  • PDF

A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구)

  • Ki, No-Gab;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode (Acoustic mode 를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Hwang, Jae-Seung;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

A Study on the Defect Types and Quality Innovation Methods for Apartment Houses (공동주택 시설공사별 하자유형 분석과 품질 혁신 방안)

  • Ju, Jae-Hyun;Bang, Hong-Soon;Choi, Byung-Ju;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.155-156
    • /
    • 2018
  • Apartment houses are now a popular form of general housing, and the construction techniques and materials quality used to construct apartments are also continuously evolving as if they were representative. However, issues concerning flaws are constantly being reported in the press. This study attempts to analyze the trend of conflicts related to defects and to analyze the types of defects received in the apartment building, to suggest the development of the integrated defect management system, and to develop the construction based on the development of the system.

  • PDF

A Study on the Air Ventilation System in Apartment Houses as a Health Concept - focused on the air ventilation and pilotis - (공동주택에 건강개념인 통기시스템에 관한 연구 - 공기순환과 필로티를 중심으로 -)

  • Cho, Cheul Hee;Lee, Teuk Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.1
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to analyze the air ventilation system in apartment houses focused on the air circulation and pilotis. The air ventilation system is used with the data which were obtained by the environmental health, urban climate, air pollution, ventilation path. The architectural element was pilotis concept connected with piloti ratio, piloti position and piloti type. The summaries of this study were as follows; 1) the well-being apartment concept, 2) the heat island phenomenon, 3) the oxygen density of air, 4) the definition of ventilation path, 5) the pilotis connected with residential environment improvement. In addition, the detailded case study to the air ventilation system in apartment houses be needed.

  • PDF

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

A Study on the Analysis of Propagation Characteristics for Floor Impact Noise in Apartment Houses (공동주택의 바닥충격음 전달 특성 분석에 관한 연구)

  • Seok Ho-Tae;Cho Kyung-Jae;Cha Min-Chul;Jae Sung-Ho
    • Journal of the Korean housing association
    • /
    • v.16 no.5
    • /
    • pp.91-98
    • /
    • 2005
  • The purpose of this study is to analysis of propagation characteristics for floor impact noise in attendance upon investigating standard of insulation performance, measurement and evaluation, understanding characteristics of a measuring factor for floor impact noise in apartment houses. Four cases which was before occupied apartment in Daegu was selected for experiment. Floor impact noise of measurement and evaluation method which are specified in the Korea Standard 2810-1, 2810-2, 2863-1 and 2863-2 was selected for this study. As the result of this study, 1) Especially, there is not a difference for apartment size, but the apartment of 40py type is lower than 30py's about $1\~2\;dB$ for light-weighted and heavy weighted impact sound. 2) The floor impact sound insulation performance is similar about measurement location of the same floor structure. 3) The floor impact sound insulation performance is not a difference about the slab area.

Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.