• Title/Summary/Keyword: apartment energy consumption

Search Result 175, Processing Time 0.017 seconds

A Comparative Study on Domestic and International Evaluation Criteria of Commissioning for Sustainable Building Certification (국내외 녹색건축인증에서의 커미셔닝 평가기준에 대한 비교 연구)

  • Jeong, Dahun;Jung, Chanwoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • Ministry of Land, Infrastructure and Transport established Heating and cooling energy conservation plan of apartment for 2017, reducing 90% compared to energy consumption of 1990. Also, at 2015 United Nations Climate Change Conference, the Ministry announced to reduce 37% of estimated $CO^2$ emission(850 million ton) at 2030. To satisfy this, it is urgent to reduce $CO^2$ emission due to the building, which takes majority amount of total $CO^2$ emission, and public interest for the commissioning of intensified building performance is uprising. However, the building commissioning at construction is not enacted, and not activated due to the lackness of promotion and will of general contractor. Furthermore, commissioning is not mandatory for obtaining G-SEED certification. Therefore, this paper describes effectiveness of commissioning with comparison of commissioning evaluation criteria of G-SEED with LEED and BREEAM, to propose making commissioning as mandatory process and drive changes in perception among stakeholders for activation of domestic building commissioning.

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.

A Feasibility Study of Green Frame(GF) for the Implementation of Low-carbon Emissions & Long-life Housing (저탄소 및 장수명 공동주택 구현을 위한 Green Frame(GF)의 타당성 분석)

  • Hong, Won-Kee;Kim, Sun-Kuk;Kim, Hyung-Geun;Yoon, Tae-Ho;Yune, Dai-Young;Kim, Seung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.57-63
    • /
    • 2010
  • The bearing wall apartments which occupy the majority of multi-residential apartment buildings built in Korea, are known for having limited architectural plan flexibility, posing challenges in terms of maintenance and remodeling. The economic losses and environmental issues resulting from the reconstruction of bearing wall apartments are now accumulating to the extent that they are becoming a national concern. Multi-residential apartment buildings, which are now the dominant form of residence in Korea, must accommodate diverse customer needs and changes in life style. A new concept of Rahmen structure with architectural flexibility is Green Frame. GF multi-residence housing is expected to reduce construction costs and shorten the construction schedule by overcoming the shortcomings of conventional bearing wall apartments. This goal is consistent with the national policies that target the reduction of resource and energy consumption. In addition, GF will be established as a core contributor to achieving a reduction in $CO_2$ emissions, which will enable the sustainable growth of domestic construction industry, and address the low-carbon green growth drive implemented by the government.

A Study of Nutritional Knowledge, Dietary Attitudes and Dietary Behaviors of Adult Women by Acne Status

  • Jinkyung Kwack;Kim, Kyungwon
    • Journal of Community Nutrition
    • /
    • v.3 no.2
    • /
    • pp.87-95
    • /
    • 2001
  • This study was conducted to investigate nutritional knowledge, dietary attitudes, and dietary behaviors of adult women, and to examine if these characteristics were different by acne status. Subjects were 106 adult women residing in Seoul recruited from clients and employers at skin care centers, and housewives from apartment complexes. Surrey instrument was adapted or modified based on literature review and dietary intakes were assessed using 24-hour recalls for two days and CAN-pro. All data was statistically analyzed using x$^2$test and ANOVA. When examined by acne status, 41.5% of subjects were categorized into acne group, 20.8% were as ex-acne group, and 37.7% as no-acne group. Parental experience of acne was significantly related to acne status(p〈 0.01). Education, employmental status, and smoking or drinking status were not related to acne status. Subjects had a moderate level of nutritional knowledge(72.7 point) and the nutritional knowledge store was not significantly different by acne status. When examined by individual items, the groups showed significant difference on the items regarding vitamin C and necessity of carbohydrates(p 〈 0.05). Subjects showed favorable dietary attitudes. Although the acne group showed more favorable attitudes on the importance of nutrition on acne, the overall dietary attitudes of the acne group were not significantly different from the ex-acne group or no-acne group. Similarly only small differences were noticed in dietary behaviors or nutrient intakes by acne status. Cholesterol consumption was hitgher in the no-acne group than in the acne group or ex-acne group(p 〈 0.01). The intakes of energy, iron, and calcium was much below the RDA in three groups. Although there were not many significant differences in nutritional knowledge, dietary attitudes, and dietary behaviors by acne status, this study provided some baseline information regarding study variables by acne status.

  • PDF

An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings (건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Recently, the insulaton design standards for reducing the energy use of buildings have been strengthened. Althoug insulation work is the most cost-effective method for reducing the primary energy consumption per unit area of a building, there are no evaluation criteria for insulation performance at the time of construction and completion inspection. The purpose of this study is to provide objective data by establishing a standard for an analysis method and a method for easily experimenting with the exterior wall thermal transmittance of an apartment house using a thermal transmittance measuring device(TESTO 435). For the exterior wall of the test subject, the specific heat per unit area exceeded 20kJ/(m2·K), and the data at the end point suitable for ISO 9869-1 were analyzed by the average method. The measured values of the thermal transmittance for 3 consecutive days converged within +5% of the desing value, and the standard deviation of the thermal transmittance by day decreased in the order of 1-Day > 3-Day > 2-Day. The standard deviation of the thermal transmittance by time period decreased in the order of 00:00~24:00 < 19:00~07:00 < 00:00~07:00. The measured value of the thermal transmittance for the time perion of 00:00 to 07:00 per day almost coincided with an error of -3% to + 2% compare to the desing value.