• Title/Summary/Keyword: apartment energy consumption

Search Result 175, Processing Time 0.026 seconds

A Basic Study on Application of Small Wind Power System Combined Ventilator in Super High-rise Apartment (1) (초고층 공동주택의 배기겸용 소형풍력발전 적용을 위한 기초연구(1))

  • Park, Jung-Ha;Kim, Jin-Woo;Jang, Ho-Jin;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.126-132
    • /
    • 2011
  • Recently, high-rise apartment is being briskly built but there are problems such as lack of ventilation, stack effect and much energy consumption. Therefore It is recommended to develop a Small Wind Power System Combined Ventilator as a solution to solve these problems. The purpose of this study is to provide basis for Small Wind Power System Combined Ventilator in super high-rise apartment. This study conducted CFD simulation (Star-CCM) according to the shape of structures, building height and distance of two structures to identify the effect of wind speed increase when the structure is installed. As a result, pyramidal type was best suited for increase of wind speed. The best place was the front of the roof to main wind direction, and the best building height was 200m rather than 300m. If two or more small wind turbines combined ventilator are installed closely, vertical position to main wind direction is recommended. Horizontal position must necessarily be avoided, but height difference between two blades more than 3m showed good performance.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

A Study on the Improvement of Cross Ventilation Efficiency in a Tower Type Apartment in Summer Season (탑상형 아파트의 여름철 통풍성능 개선에 대한 연구)

  • Cho, Keun-Je;Chang, Hyun-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.299-304
    • /
    • 2012
  • In terms of plane structure, tower-type apartments have several disadvantages compared to flat-type apartments in the aspect of ventilation rate. Such disadvantages may not produce good indoor cooling effects with natural ventilation inside the heated apartments in hot summer days, so they may cause high energy consumption by an increase in cooling load. The purpose of this study is to investigate ways for improving the indoor thermal environment of tower-type apartments in summer by conducting quantitative evaluations of the airflow distribution in households.

  • PDF

A Study on Quantity of CO2 Emission about Remodeling Cycle at High-rise Apartment housing (초고층 공동주택 세대내 개보수 주기에 따른 이산화탄소 배출량 연구)

  • Kim, Dayoo;Kang, Seungyi;Je, Haeseong
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.75-80
    • /
    • 2010
  • The goal of this study is to figure out the remodeling cycle at high-rise apartment housing and to analysis on quantity of $CO_2$ emission about remodeling cycle. The process of research is as follow; 1) Estimate the remodeling cycle through survey targeting residents at high-rise apartment building. 2) Simulate conditions on the high-rise apartment housing. 3) Calculate quantity of energy consumption and $CO_2$ emission 4) Derive elements that are on high level of environmental load evaluation. The main results of this study is as follow; 1) The cycle of finishing such as wallpaper is shorter than the cycle of building equipment such as elements in a toilet. 2) According to result of calculating $CO_2$ emission, fabric wallpaper and mortar are main factors that impact on the environment. The results is important to show reference points on quantitative measuring evaluation for the environmental-friendly extent.

A Study on the Energy and Water Consumption and their Patterns as Vertical Locations of Apartment Housing Units (아파트 단위 세대의 수직 위치 별 에너지 및 물 사용 규모와 패턴에 관한 연구)

  • Song, Dong-Hun;Kim, Kyung-Tae;Lee, Seung-Jun;Shin, Hyun-Ik
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.53-63
    • /
    • 2017
  • The purpose of this study is to present an integrated analysis for energy use and its patterns as vertical locations of the dwelling units in apartment buildings which are located in an urban area and constructed by a renowned contractor. In order to enhance the effectiveness of the method, the original data of electricity, water, and gas bills which directly reflect the energy use are sorted and analyzed into several groups as vertical locations in each building. And also, by use of comparing and contrasting the data on a monthly and yearly basis, the accuracy of analyses for seasonal energy use and its patterns is strengthened. Comparative analyses used in this study describe the results that vertical locations of dwelling units do not have much influence on electricity and water usage, but are closely related with gas usage for a heating season. According to the analysis of gas usage, the units on the ground and right above pilotis need enhancement in the insulations for heating to mitigate energy loss. Also, the analysis for the middle floor units in each group describe the fact that the gas usage of the units on the ground is consumes 1.5 times greater than that of the typical floors. Therefore, enhanced insulation strategies need to be considered against the adverse condition that the heat loss increases as the wall facing the outside air increases or as the wind velocity increases through the pilotis.

Life-cycle Environmental Impact Assessment of High-rise Apartments

  • Kim, Samuel;Kim, Se-Hwan;Lee, Sung
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • Concern about global environment has been increasing in recent years. Efforts to minimize the environmental impact to the globe as well as human beings have increased, especially in the late twentieth century. The study researches one of the solutions for the environmentally friendly building construction, which can contribute to sustaining the world environment. Assessment and proposals are made for high-rise apartments, one of the most popular construction types nowadays in Korea. Since the volume of high-rise apartment construction is so great, a small improvement in each building will make a great contribution. Assessments are made over the life-span of apartment buildings. A tool named EIAHA (Environmental Impact Assessment for High-rise Apartment) has been made through references from western examples, mainly in the UK. The components of EIAHA include passive design strategies, building materials, energy consumption during building operation and management/maintenance. Although the issues are on a global scale, solutions are sought on regional scale. Korean high-rise apartments are assessed with the tool and suggestions for sustainable development are made mainly for improvement of embodied energy of building materials and the life of buildings.

  • PDF

A Study on the Greenhouse Gas Intensity of Building Groups and Regional in Korea (국내 에너지다소비건물의 용도별.지역별 온실가스 배출원단위분석 연구)

  • Lee, Chung-Kook;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • Our country set the mid-term reduction goal of greenhouse gases up to 2020 in accordance with Bali roadmap agreed in 2007 through the negotiation with UNFCCC in 2009 and specified the proper goal as by the Basic Act on Green Growth that went into effect at April, 2010. First of all the enlargement of green building construction has been suggested as a worldwide strategy to achieve the green house gas reduction. Building area is one of most important sectors for the countermeasure of climate change agreement and the achievement of national green house gas reduction goal and the need to reduce its green house gases has been increased accordingly. The objective of the study is to examine the status and characterization of mass energy consumption local governmental buildings' green house gas emissions depending on usage (hotel, school, apartment, hospital) through the green house gas emission source unit analysis. The result indicated that the energy source unit was proportional to green house gas source unit and hotel showed the highest green house gas emission source unit per open area of construction unit, followed by hospital, apartment, and then school. In case of apartment, green house gas emission source unit per open area of construction unit decreased as year went on. Meanwhile school building showed a striking increase in the annual energy source unit.

A Case Study on the Acclimatization's Housing for Environmental Load Reduction (환경부하 저감을 위한 기후순응주거 사례연구)

  • Cho, Sung-Woo;Oh, Se-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

Study on Application and Economic Evaluation of New Insulation Material to Confront High Oil Price: Focus on an Apartment (고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로)

  • Hyun, Jong-Hun;Kim, Ji-Yeon;Park, Hyo-soon;Choi, Moo-Hyuck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.746-751
    • /
    • 2008
  • The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case 1, 2) and vacuum or triple glazing can retrieves the investment with $120 and $140$\sim$150 per barrel each.

Study on Thermal Comfort in according to Rate of Opening Windows of Flat-type Apartment (판상형 아파트의 창문개폐율에 따른 열쾌적도 분석)

  • Kim, Sung Gil
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.93-98
    • /
    • 2013
  • The purpose of this study is to analyze the rate of opening windows that makes residents of a flat-type apartment feel pleasant in summer time. A few conditions were simulated on the wind flow that pass through internal and external spaces of the flat-type apartment, utilizing CFX program. The simulation was made with the criteria for the rates of opening window at 20%, 50%, 70% and 100%. When the rate of window opening was more 50%, the wind speed(more than 1m/s) that makes the residents feel pleasant was observed in more 60% of the internal space. When the all windows of the apartments were opened, the heat island phenomenon was almost disappeared and the pleasant wind flow was more evenly distributed in the external spaces. If residents of apartments recognize the result of this study and practice in agrement on opening windows in summer, it is expected to contribute to minimizing the energy consumption for air conditioning.