A Consideration of the Present Status of Support for Community Revitalization in the Japanese UR Rental Housing Complex (일본 UR임대주택단지의 커뮤니티활성화 지원실태에 관한 고찰)

  • Lee, Su-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.3
    • /
    • pp.103-111
    • /
    • 2020
  • This study aims to analyze community support methods and specific attainments of UR rental housing complex S in Japan and examine the present state of community formation.. UR rental housing S is part of the community revitalization support project launched by UR Urban Agency for creating exchanges among residents in the rental housing complex and in this study, the community support project from February to November 2013 was considered. As community revitalization support tasks, five types of events and exchange meetings were held. While the events and exchange meetings continued, even the residents who did not join the residents' association began to make an exchange with each other and their identity as residents enhanced, which means there was a change in the sense of community. Moreover, it is thought that a good solution to maintaining the chance for the events and exchange meetings after the support project is that residents of the younger generation actively cooperate in management as the residents' association members. 5 years after the support project, the present condition of activities of complex residents was examined, but the Residents' Association was disbanded due to the aging of residents, a growth in residents and low participation rates of the younger generation. Besides, there is a complete absence of community activities in the complex now.

A Strategy to Improve Customer Service for Apartment Building Units (공동주택 상품의 고객서비스 개선 전략 연구)

  • Lee, Hyun-Min;Lee, Dong-Hoon;Kim, Sun-Kuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.163-172
    • /
    • 2009
  • As customers are becoming increasingly important in corporate management, there is a growing demand for migration to customer-focused organizational structures. Unlike the manufacturing industry, the construction industry is non-iterative and non-standardized. As a result, a wide variety of materials, human resources, technologies and equipment must be mobilized in complex work activities to complete a structure. Consequently, surprises are bound to occur as such work activities progress. This paper intends to study a strategy that is designed to improve customer services for apartment building units. It aims primarily to focus on cost control and brand management. Housing tenants and industry experts are surveyed to collect input for issue analysis. In addition, the external circumstances and internal capabilities of major builders in Korea are analyzed, and a SWOT analysis is performed regarding market conditions related to customer service. These analysis results are utilized to develop a strategy implementation plan over different time frames, and the operational resources available for such strategy implementation are analyzed in order to forecast its performance. This research will facilitate communication between construction companies in Korea and their customers by proposing a customer service improvement strategy for apartment building units, and is expected to provide resource material for a strategic analysis of efforts to fully incorporate customer requirements

A Study on the Risk Evaluation of Apartment Development Project based on VE (VE기반 공동주택 개발사업 리스크 평가에 관한 연구)

  • Lee, Hyun-Chul;Shin, Seog-Bae;Hong, Ju-Hyun;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.4
    • /
    • pp.14-25
    • /
    • 2009
  • Development work of apartment houses is a complex medium-and long-term project requiring grand resources and work force. Since in combination inner and outer project variables relate to project output, uncertainties caused by not only a given site condition but also politic, economy and social sectors are generated during the project. These risks influence output of the project as important factors, and ultimately as management variables in priority giving an effect on earnings and the financial structure of enterprises they should be manageable with the risk reduction plan. In this point of view, this study focused on development work of apartment houses among construction project. Risky factors were deduced, analyzed and evaluated based on Value Engineering from planning to designing to executing to maintaining. Eventually, this study showed the foundation guaranteeing competitive power of public and private construction sectors.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

Modeling of Winter Time Apartment Heating Load in District Heating System Using Reduced LS-SVM (Reduced LS-SVM을 이용한 지역난방 동절기 공동주택 난방부하의 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.283-292
    • /
    • 2015
  • A model of apartment heating load in a district heating system could be useful in the management and utilization of energy resources, since it could predict energy usage and so could assist in the efficient use of energy resources. The heating load in a district heating system varies in a highly nonlinear manner and is subject to many different factors, such as heating area, number of people living in that complex, and ambient temperature. Thus there are few published papers with accurate models of heating load, especially in domestic literature. This work is concerned with the modeling of apartment heating load in a district heating system in winter, using the reduced least square support vector machine (LS-SVM), and with the purpose of using the model to predict heating energy usage in domestic city area. We collected 23,856 pieces of data on heating energy usage over a 12-week period in winter, from 12 heat exchangers in five apartments. Half of the collected data were used to construct the heating load model, and the other half were used to test the model's accuracy. The model was able to predict the heating energy usage pattern rather accurately. It could also estimate the usage of heating energy within of mean absolute percentage error. This implies that the model prediction accuracy needs to be improved further, but it still could be considered as an acceptable model if we consider the nonlinearity and uncertainty of apartment heating energy usage in a district heating system.

Temporal and Spatial Distributions of PM10, NOx and O3 around the Road (도로 주변의 PM10, NOx 및 O3의 시공간적 농도 분포 연구)

  • Kwon O-Yul;An Young-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.440-450
    • /
    • 2006
  • PM10, NOx, and $O_3$ were measured at six locations, of which each three is horizontally and vertically distributed respectively, in an apartment complex around the heavily traffic road. Those were measured seven times a day with two hours interval starting from 8 o'clock in the morning for 15 days during May 2005 $\sim$ September 2005. PM10 and NOx showed high concentrations in rush hours while low concentrations in midday due to the direct emissions from automobiles in operation. Temporal variations of 01 showed very much similar trend appeared in normal urban atmospheres. The spatial distributions of PM10, NOx and $O_3$ showed that almost all of concentrations were higher in a row of Roadside > Surface at 130 m apart from the road > Surface at 230 m apart from the road > 3rd floor of apartment building > 15th floor of apartment building > 27th floor of apartment building. Model equations, which can project spatial concentration distributions, were constructed by combining the horizontal and the vertical linear regression equations derived from six mean values corresponding to six measuring locations. According to inter-comparison of PM10, NOx, and $O_3$ with the constructed model equations, concentration gradients were higher in a row of Vertical direction of NOx > Vertical direction of PM10 > Horizontal direction of NOx > Horizontal direction of PMIO > Vertical direction of $O_3$ > Horizontal direction of $O_3$. Why concentration gradient of particulate PM10 is lower than that of gaseous NOx is in question, and should be studied.

A Study on the Agreement a rate Encouraging Restriction Primary factor Multi-family Housing Remodling (공동주택 리모델링사업의 동의율 확보 제약요인에 관한 연구)

  • Kim, Dong-Jae;Kim, Gab-Youl
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.885-890
    • /
    • 2008
  • Until now, the domestic construction market has been formed focusing on new construction and reconstruction in the apartment industry. Recently, however, the remodeling market for old structures have shown a tendency towards land shortage and land price increases in the major cities: the reinforcement of regulations regarding reconstruction; expenditure reduction and the solving of environmental problems by regarding old structures is pursuing low costs and maximum efficiency. The interest in remodeling is increasing, however, remodeling has not been successfully initiated in the apartment division for a reasonable period of time. Consequently to acquire mutual agreement for remodeling from the residential occupants. In order to evaluate profitability, it is necessary to set priorities and reasonable criteria for remodelling and to this end, it is also required to assess each fact of remodelling in view of both customers and supplied. Thus, a sample apartment housing complex was analyzed for geographic location, surrounding environment floor area ratio, site area, number of households, number of stories and unit area and thereupon, its remodelling profitability was analyzed to select an effective remodeling method as an alternative case for apartment house owners and remodelling.

  • PDF

Evaluation on the Photovoltaic Module Arrangement Planning Considering Shading Conditions in Apartment Buildings (음영조건을 고려한 공동주택 옥상 태양광모듈의 배치계획 평가 연구)

  • Lee, Keo-Re;Lee, Yoon-Sun;Lim, Jae-Han
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.169-179
    • /
    • 2019
  • During the initial design stage of apartment complex, the photovoltaic(PV) system has been considered as an alternative of renewable energy system and planned to install at the rooftop floor level in general. The electric power generation characteristics can be influenced by the block layout, building orientation and roof top structure because of azimuth angle, tilt angle, and partial shading. This study aims to investigate power generation characteristics of photovoltaic system in apartment buildings by considering the partial shading conditions due to the block layout, building orientation and roof-top structures. For the photovoltaic module arrangement planning in rooftop floor level, shading areas were firstly analyzed due to the adjacent building structure. And the annual and seasonal power generation of PV system were analyzed through the PVsyst simulation results. The results show that shading period at the roof top surface can be increased due to the parapet and water tank. Initial design power capacity can be decreased by considering the daily insolation period and distance between PV modules through the shading simulation. As the number of PV modules decreases, the annual power generation can be decreased. However annual power generation per unit area of PV modules can be increased and performance ratio can be increased above 80%. Also the power generation of PV system can be critically affected by building orientation and the performance ratio can be drastically decreased in east-oriented buildings due to the shading problems caused by adjacent structures at roof top level such as parapet and water tank.

Effects of Environmental Infrastructure Regeneration in Urban Region - A Case Study of M Apartment Complex in Daejeon (도시 단지내 환경 인프라 재생 효과 고찰 - 대전시 M 아파트 단지 사례연구)

  • Park, Kiyong;Choi, Changkyoo;Shin, Jongseok;Park, Heekyeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.353-359
    • /
    • 2015
  • This study introduces a resource recycling system in urban apartment complex using four different technologies. The four technologies, called 4G, include a production technology for reclaimed water (Green water), a biogas production technology from organic waste (Green biogas), a reuse technology of rainwater (Green rainwater), and urban agropark (Green pyramid). Green water is the technology for producing the reclaimed water from wastewater, rainwater and underground water, and the average concentrations of BOD, SS, T-N and coliform of reclaimed water were 7.8mg/L, ND (not detected), 4.9mg/L and ND, respectively. Green biogas is the technology for producing biogas and effluent after treating organic wastes (e.g. food waste and night soil) discharged from households, and the average production rates of hydrogen and methane were $0.33m^3/m^3/d$ and $0.24m^3/m^3/d$, respectively. Green pyramid, agricultural farm operated by biogas and reclaimed water, provides a healthy and recreational space for residents, and plant growth rates using treated water and reclaimed water showed height of 1.32cm and weight of 112.8g. Therefore, 4G technologies can improve the recycling rate and treatment efficiencies of waste and wastewater in an apartment complex.

Analysis on Residents Behavior and Determinants of Satisfaction to the Exterior Space in High-rise Apartment complex. (도시 고층아파트단지 주거민의 외부공간 이용행태 및 만족요인 분석)

  • 이현택;이철희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.2
    • /
    • pp.79-93
    • /
    • 1990
  • The purpose of this study is to establish better residential environment in APT. complex. In this study, the actual conditions of exterior space, user behavior and degree of satisfaction are investigated and analyzed on the 5 high-rise story APT complex in Taegu city. The results of this study were as follow ; The size and arrangement of organizational elemnnt to exterior space in APT. complex have been regulated by law and regulations as the buildings coverage and floor space index, but housinghold and accessibility to the racility will be simultaneously considered to raise Quality of the residential environoment. The main user behavior to exterior space in APT. complex was practical activity and the user behavior pattern by week and among APT. complex were found similiarly. In the ratio of use to exterior space in APT. Complex, that of high-rise residents were lower than that of lowrise residents. In the degree of satisfaction by property of variables to exterior environment In APT. comples, physical of buildings, social - psychologic, managerial economical, physical property of exterior space were estimated positively, but properly of facility were estimated negatively. The degee of satisfaction to exterior environment in APT. complex was highly Influenced by green space, site size. As a result of ractor analysis, the four factors were drawn out from exterior environment in APT. complex. and the factors that have an effect on the degree of residents' satisfaction by factorscore were found in the order of importance as fallow ; managemental, physical, environmental, organizalional factor. Therefore, devilopment of APT. complex should be considered in a view of environmental psychology according to physical organization for used in the future. It is recommended that this problems should be necessitated to be more deeply studies in the future.