• Title/Summary/Keyword: aortic valve

Search Result 655, Processing Time 0.026 seconds

Valve Replacement: Report of 100 Cases (심장 판막 이식 100례 보고)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.199-212
    • /
    • 1978
  • One hundred cases of cardiac valve replacement were done at this Department in the period from June 1968 to May 15, 1978. Seventy-one cases of mitral, 12 aortic, and one tricuspd valve were replaced. There were 16 cases of double valve replacement, 10 aortic with mitral and 6 mitral with tricuspid valve replacement. Prosthetic valves-Beall, Bjoerk-Shiley, Starr-Edwards, Wada-Cutter, Magovern-Cromie, and Smeloff-Cutter valves-were used. But in recent years bioprosthetic valves-Hancock, Carpentier-Edwards, and Angell-Shiley valves-were used mainly due to the difficulties of postoperative anticoagulation, especially for the rural Korean patients. Over all operative mortality was 2896, 26.2% for single and 37.5% for double valve replacement cases. There were 4 postoperative thrombo-embolism cases with 2 deaths. Four postoperative subacute bacterial endocardities cases with 2 deaths were noted. Three cases of postoperative congestive heart failure succumbed. Two cases of peri valvular leakage, one of which needs reopration, were found. There were 28 operative and 9 late deaths, leaving 63 long-tel m survivors, who showed marked improvements.

  • PDF

Durability of the Low Profile Ionescu-Shiley Valve in Aortic Position (이오네스큐 단고형 대동맥판의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1041-1047
    • /
    • 1992
  • The consecutive 35 patients underwent isolated aortic valve replacement with the low-profile model of the Ionescu-Shiley pericardial xenograft valve from 1984 to 1991. Operative mortality was 2.9%, and early survivors were followed up for a total 136.1 patient-years[Mean$\pm$SD, 4.00$\pm$2.14 years]. The linearized late mortality was 2.204% /pt-yr. Three patients required rereplacement of the valve with overall valve failure rate of 2.204% /pt-yr: two for endocarditis and one for paravalvular leak. There was no case of primary tissue failure. The linearized annual rates of complication were: thromboembolism 0.735% /pt-yr, bleeding 0.735%pt-yr, and endocarditis 2.204% /pt-yr. The actuarial survival at 8 years of follow-up was 90.4$\pm$5.3%, and the probabilities of freedom from thromboembolism and from rereplacement were 95.6$\pm$4.4% and 88.2$\pm$6.7% at 8 years respectively. Although the low profile Ionescu-Shiley pericardial valve provided favorable clinical performance comparable with the standard model up to 8 years, it needs prolonged follow-up to assess the pattern of its durability.

  • PDF

Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases- (인공심장판막의 재치환술)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

Surgical Management of Aortic Insufficiency in Behcet's Disease (베체트씨병에 의한 대동맥판 폐쇄부전의 수술적 치료)

  • Kim, Kyung-Hwan;Kim, Ki-Bong;Kim, Won-Gon;Kim, Joo-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.33 no.5
    • /
    • pp.391-397
    • /
    • 2000
  • Background: Cardiac involvement of Behcets disease is very rate, however, the prognosis of Behcet disease depends on cardiovascular complications. In this article, we described surgical treatment of aortic insufficiency with Behcets disease. Material and Method: From March 1986 to February 1998, we operated on 10 patients of aortic insufficiency with Behcets disease. Male to female ratio was 8 to 2, and age ranged from 21 to 40 years(mean 32.8 years). There were 8 patients with evidence of Behcets disease and another 2 patients had some suspicious findings of Behcets disease(i.e., prosthetic value dehiscence, hypertrophied aortic wall). Adequate preoperative medical treatment for Behcets disease was done in 3 patients. Result: We performed 24 open heart surgeries in 10 patients. Redo value replacements using prosthetic valves were done in 4 patients. Among them, 2 patients were operated on for a second redo valve replacement and one of them operated on for a 4th and 5th operation because of recurrent paravalvular leakage. These 4 patients expired. 1 patient who had undergons tissue value replacement is alive. 1 patient who underwent Cabrol operation expired dut to rupture of graft anastomosis site. We used homografts in 3 patients. In 2 of them, we performed aortic root replacement and subcoronary valve replacement in another patient. The patient who underwent subcoronary valve insertion had remnant aortic insufficiency, so we are closely observing him. We also performed Ross operation in a 24 year old female who suffered severs aortic insufficiency and endocarditis after aortic valvuloplasty. 5 patients are alive and mean follow up duration is 49.0 months. Among them, we used homografts or sutografts in 4 patients. We could observe excellent clinical results in the patients who underwent aortic root replacement using homograft and they were treated medically for Behcets disease. Conclusion: We concluded that adequate preporative diagnosis, clinical suspicion, and periopertive medical treatment for Behcets disease are very important for the result of surgical management of aortic insufficiency with Behcets disease. The use of homograft or autograft was helpful for the healing of anastomosis site and we should carefully observe the long term follow up results.

  • PDF

Isolated aortic valvular heart disease : analysis of etiology and surgical experience (대동맥판막질환의 임상적 고찰 -판막병리 및 임상성적에 대하여-)

  • 이승구
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.300-308
    • /
    • 1987
  • Clinical and pathologic data were reviewed in 20 patients who had have surgery for isolated aortic valvular heart disease between April 1978 and April, 1987. Hospital mortality was 10%, with no additional late mortality during a mean follow-up period of 24.1 months. Prosthetic valve failure developed in 3 patients and two had reoperation. Niety four percent of the survivors who were in NYHA Funtional class III or IV before operation are now in class I or II. Ninety percent of all patients are still alive at a maximum follow up of 9 years. The clinical histories, gross and histologic examination of valves estabilished the causes for isolated aortic valve disease: 3 rheumatic, 2 congenital bicuspid, 2 hypertention, 2 aortitis and each one case of floppy valve, medial cystic necrosis of aorta, bacterial endocarditis. But etiology was unknown in 8 cases. Sixteen patietns had myxoid degeneration, defined as significant disruption of the valve fibrosa and its replacement by acid mucosaccharides and cystic changes. Myxoid degeneration was also the primary pathologic abnormality in the patients with 2 hypertention, 2 rheumatic, 1 aortitis, 1 bacterial endocarditis, 1 floppy valve, 1 congenital bicuspid. The patients with myxoid degeneration of uncertain origin were 8. Histologic finding of all of them revealed nonspecific patients with myxoid degeneration of uncertain orgin were 8. Histologic finding of all of them revealed nonspecific chronic valvulitis with myxoid degeneration. This finding may indicate that the etiology w uld be infectious.

  • PDF

Annual Open Heart Surgery: Report of 416 Cases in 1980 (연간 개심술 416례 보고 [1980 년도])

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • In 1980, 416 cases of open heart surgery were done in this Department with over all operative mortality of 12.3%. 1. There were 288 congenital anomalies consisting of 174 acyanotic and 114 cyanotic varieties, which showed operative mortality of 6.9% and 25.4% respectively. 2. There were 128 cases of acquired lesions, 124 valvular disease and 3 myxoma being the main lesions. 3. There were 128 cases of valve replacement with operative mortality of 7.8%. 4. The most frequently operated anomaly was VSD, 90 pure VSD and 21 cases were associated with one or 2 cardiac anomalies. Over all operative mortality in 111 VSD cases was 8.1% but in 90 pure VSD cases it was 6.7%. 5. Tetralogy of Fallot showed the highest incidence in cyanotic group with 88 cases, consisting of 68 pure and 20 with other cardiac anomalies. Over all mortality in 88 cases was 19.3% but in pure form 16.2%. 6. In 128 valve replacement cases over all mortality was 9.4%. There were 85 mitral, 11 aortic, 2 tricuspid, 21 mitral with aortic, 6 mitral with tricuspid, 3 mitral, aortic, and tricuspid valve replacement cases. For mitral valve replacement operative mortality was 5.9%. 7. Twenty-one cases of babies under 10kg body weight were operated on with over all operative mortality of 28.6%. Sixteen cases of VSD were found with operative mortality of 25%. 8. Among 128 cases of valve replacement 7 were under the age of 15 years and 12 were between 15 and 20 years old. Five pediatric cases underwent mitral valve replacement without mortality, 9 year old boy was the youngest among them. In this Department open heart surgery for infancy and complex anomalies showed still hip operative risk which should be improved in the coming years. For open heart surgery Shiley oxygenators and 2 sets of A-O de-lux 5 head roller pump were utilized exclusively. For valve replacement Ionescu-Shiley bovine pericardial xenografts were mainly used. In pediatric and rural patients Persantin with aspirin regimen was satisfactorily administered for anticoagulation after valve replacement. Routinely Coumadin was administered for one year after valve replacement* In patients who had thrombus on valve sites, chronic atrial fibrillation, and giant left atrium Persantin-Aspirin regimen was used when one year coumadin administration was discontinued.

  • PDF

Thoracoscopic Aortic Valve Replacement assisted with AESOP (Automated Endoscope System for Optimal Positioning) 3000 (AESOP 3000을 이용한 흉강경적 대동맥 판막 치환술)

  • Shin Hong Ju;Kim Hee Jung;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.507-509
    • /
    • 2005
  • Open heart surgery via right thoracotomy can be accomplished in atrial septal defects, and mitral valve diseases. Recently, thoracoscopic atrial septal defect closure, mitral valve repair, Maze operation, and minimal invasive direct coronary artery bypass (MIDCAB) are accomplished with AESOP 3000. However, there is no report of thoracoscopic aortic valve replacement in Korea. We report a successful thoracospic aortic valve replacement assisted with AESOP 3000 in a 31-year-old female patient.

Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block (완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술)

  • Jo, Kwan Hoon;Kim, Inho;Ann, Soe Hee;Oh, Yong Seog
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.

A Case of Ascending Aortic Dissection with Severe Aortic Regurgitation Diagnosed by Echocardiography (심장초음파검사로 진단된 중증 대동맥판역류를 동반한 상행대동맥박리증 1예)

  • Kim, Sung-Hee;Lee, Ok-Kyoung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2020
  • Aortic dissection refers to the separation of the aorta into a true and false lumen as the medial membrane of the aorta is torn along the long axis due to a high aortic pressure when a minute rupture occurs in the aortic lining. The mortality rate is very high, and aortic dissection occurs 2~5 times more in men than women. The prevalent age range is 50~70 years old. In this case, the authors experienced a diagnosis of aortic dissection that occurred in a young woman in her 30s, which does not occur frequently. In the process of tracking severe aortic regurgitation, aortic valve prolapse was initially suspected. We report this case because aortic dissection could be diagnosed by observing the intimal flap of the ascending aorta in the process of confirming this suspected part.

Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics. (CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF