One hundred cases of cardiac valve replacement were done at this Department in the period from June 1968 to May 15, 1978. Seventy-one cases of mitral, 12 aortic, and one tricuspd valve were replaced. There were 16 cases of double valve replacement, 10 aortic with mitral and 6 mitral with tricuspid valve replacement. Prosthetic valves-Beall, Bjoerk-Shiley, Starr-Edwards, Wada-Cutter, Magovern-Cromie, and Smeloff-Cutter valves-were used. But in recent years bioprosthetic valves-Hancock, Carpentier-Edwards, and Angell-Shiley valves-were used mainly due to the difficulties of postoperative anticoagulation, especially for the rural Korean patients. Over all operative mortality was 2896, 26.2% for single and 37.5% for double valve replacement cases. There were 4 postoperative thrombo-embolism cases with 2 deaths. Four postoperative subacute bacterial endocardities cases with 2 deaths were noted. Three cases of postoperative congestive heart failure succumbed. Two cases of peri valvular leakage, one of which needs reopration, were found. There were 28 operative and 9 late deaths, leaving 63 long-tel m survivors, who showed marked improvements.