• 제목/요약/키워드: aortic stenosis

검색결과 251건 처리시간 0.025초

분리된 막성 대동맥 판막하 협착증;1례 보고 (Discrete Membranous Subvalvulr Aortic Stenosis - A Case -)

  • 오중환
    • Journal of Chest Surgery
    • /
    • 제25권7호
    • /
    • pp.739-744
    • /
    • 1992
  • Discrete membranous subaortic stenosis[DMSS] is one of the subtype of congenital left ventricular outflow obstruction and can be associated with aortic regurgitation, infective endocarditis, ventricular obstruction. DMSS should be removed early, when diagnosed, and completely before secondary myocardial changes occur. Recently we experienced a case of DMSS with aortic regurgitation, and its left ventricular outflow tract obstruction[LVOTO] peak systolic gradient was 10lmmHg. Resection of membrane and aortic valve replacement is adequet for LVOTO and postoperative pressure gradient was 26mmHg. Postoperative echocardiogram shows no obstuctive membrane and well functioning aortic valve.

  • PDF

Williams' syndrome을 동반한 선천성 대동맥 판상협착 -치험 1례- (Congenital Supravalvular Aortic Stenosis Associated with Williams'Syndrome -One Case Report-)

  • 박진석
    • Journal of Chest Surgery
    • /
    • 제28권4호
    • /
    • pp.391-394
    • /
    • 1995
  • We expericenced one case of surgical treatment of congenital supravalvular aortic stenosis associated with Willjams` syndrome using Dory procedure. A 22 years-old male patient was admitted to the cardiology department due to dyspnea,easy fatigue,dizziness. On physical examination,systolic murmur was audibled at fight second parasternal intercostal space and his general appearance was elfin face and mental retardation was noted. Cardiac catheterization was revealed as a supravalvular aortic stenosis and pressure gradient was 45mmHg between the left ventricle and the aorta. Successful surgical treatment was accomplished with Inverted Y procedu~:e using Dacron patch[Doty procedure . Postoperative course was uneventful and he was discharged in good condition.

  • PDF

퇴행성 대동맥판 협착증의 중증도 평가: 증례보고 3례 (Assessment of the Severity of Degenerative Aortic Stenosis: Three Case Reports)

  • 김성희
    • 대한임상검사과학회지
    • /
    • 제51권2호
    • /
    • pp.270-275
    • /
    • 2019
  • 노령 인구의 기대 수명이 증가함에 따라 퇴행성 판막 질환이 많아지고 있다. 류마티스성 판막 질환인 승모판 협착증과 대동맥판 역류가 점차적으로 감소하고 석회화된 퇴행성 대동맥판 협착증, 승모판 탈출증 및 허혈성 심장 질환으로 인한 승모판막 폐쇄 부전의 빈도가 증가하고 있다. 심장초음파는 심장판막질환의 진단은 물론, 치료방법 및 수술 시기와 더불어 예후 평가에서도 매우 중요한 도구이며, 판막질환을 평가할 때 모든 판막을 자세하게 관찰하는 이면성 심장초음파가 우선해야 한다. 흔히 접하는 퇴행성 판막질환에 대한 이해와 함께 임상적 특성을 파악하여 심장초음파를 정확하게 시행하는 것이 가장 중요하다. 아울러 대동맥판 협착증의 중증도 평가가 수술적 적응증을 판단하는 데 꼭 필요한 검사인만큼 정확한 판단 기준에 따라 평가하여 환자의 정확한 진단 및 치료가 이루어지도록 해야 한다. 퇴행성 대동맥판 협착증 환자 3례를 통해 심장초음파 검사의 중증도 평가를 쉽게 이해할 수 있기를 바라며 퇴행성 판막 질환의 심초음파 소견을 숙지하는 것이 심장초음파검사를 정확하게 수행하는 것에 수반되어야할 것으로 사료된다.

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • 제52권5호
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.

대동맥판막하 막상협착증 치험 2례 (Discrete Membranous Subaortic Stenosis)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.727-733
    • /
    • 1988
  • Two cases of the discrete membranous subaortic stenosis were experienced at the Department of Thoracic & Cardiovascular Surgery, National Medical Center, Seoul, Korea. Case I was 31 years old male with a history of aortic valve replacement[Ionescu-Shiley, 19mm] at the other hospital in 1980. Heart failure was noticed 6 years later. On cardiac catheterization, pressure gradient between left ventricle 4 aorta was 104 mmHg, but subvalvular aortic stenosis was not detected by preoperative 2-D echo <% left ventriculogram. Above case revealed stenoinsufficiency of the prosthetic valve. Under the diagnosis of the prosthetic valve failure, re-do aortic valve replacement[Bjork-Shiley, 23 mm] was done. During operation, the discrete membranous subaortic stenosis was incidentally found, and it was completely resected. So we thought that above discrete membranous subaortic stenosis was not detected at first operation, and it was progressed during 6 years, and accelerated the degeneration of the prosthetic valve. Case II was 20 years old female. Her complaints were exertional dyspnea, angina, syncope, which were aggravated since 5 years ago. 2-D echo <% left ventriculogram revealed the discrete membranous subaortic stenosis. Pressure gradient was 20 mmHg, but her symptoms were serious. Associated cardiac anomaly was the persistent left superior vena cava without connection with right superior vena cava. Complete excision of the membranous tissue was done. Post-operative pressure gradient between left ventricle & aorta was absent, and her complaints were nearly subsided. Both cases were type I according to the Newfeld classification of the discrete subvalvular aortic stenosis, and complete excision of the membranous tissue was done without myotomy or mymectomy. And short-term follow-up results[Case I:2 years, Case II: 1 ~ years] were good except soft systolic murmur[grade II/VI] at the aortic area in both cases.

  • PDF

변형 Konno 술식을 이용한 죄심실 유출로 협착의 수술치험 - 3례 보고 - (Experience of Modified Konno Operation in Patient with LVOTO)

  • 박승일;김용진
    • Journal of Chest Surgery
    • /
    • 제23권1호
    • /
    • pp.192-200
    • /
    • 1990
  • The results of conventional operative resection of diffuse subaortic stenosis[tunnel subaortic stenosis] have been less than satisfactory. We have performed modified Konno operation to enlarge the outflow tract of both ventricle with a patch in three patients with diffuse tunnel subaortic stenosis in the department of Thoracic and Cardiovascular Surgery, Seoul National University Children`s Hospital. Preoperative left ventricular aortic pressure gradients were 135 mmHg, 50 mmHg, 80 mmHg respectively in these patients. After right ventriculotomy, the septotomy was done and extended beyond the limit of the stenosis and fibrous and/or muscular tissue was removed from each edge of septal incision. After adequate widening of the tunnel subaortic stenosis with various patches, right ventricle was closed primarily or with prosthetic patches successfully. One patient who was diagnosed as complete atrioventricular septal defect had complete AV block preoperatively and was implanted permanent pacemaker, and others who were sinus rhythm preoperatively have no serious postoperative rhythm disturbance. One patient developed mild postoperative aortic insufficiency and one who had preoperative aortic insufficiency has still same grade of aortic insufficiency after operation. All had good postoperative hemodynamics without any postoperative residual pressure gradient.

  • PDF

4차원 자기공명영상을 활용한 돼지 심장 ex-vivo 이첨판 모델 유동 가시화 및 유동 특성 분석 (4D flow MRI based flow visualization and quantification of bicuspid valvular flow using ex-vivo porcine model)

  • 권민성;박성호;허형규
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.12-17
    • /
    • 2023
  • Aortic valve stenosis is a heart valve disease caused by the accumulation of calcium in the valve, which can divide into tricuspid aortic valve (TAV) stenosis and bicuspid aortic valve (BAV) stenosis depending on the shape of natural valve. In this study, pig heart-based TAV and BAV ex vivo models were fabricated, and the flow characteristics behind a valve were analyzed using 4D flow MRI. Flow behind normal TAV was uniformly distributed, while BAV asymmetrically opened with an eccentric strong jet. Especially, BAV ex vivo model exhibited a secondary flow in the region where the valve closed. In addition, BAV had a 26% higher peak velocity while maintaining similar stroke volume compared with normal TAV. This study would be helpful for understanding the flow characteristics for BAV AS patients.

선천성 대동맥 판막 협착증 치험 2예 (Congenital Aortic Stenosis: Report of 2 Cases)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제11권2호
    • /
    • pp.194-198
    • /
    • 1978
  • Congenital aortic stenosis, a relatively uncommon congenital heart disease, may cause heart failure and may be fatal. In recent years, increased clinical awareness and improved diagnostic and operative technique has made accurate diagnosis and successful treatment possible. Recently we experienced 2 cases of congenital aortic stenosis, and which was corrected surgically. The first case was 9 years old boy, and second case was 16 years male. Preoperative diagnosis was entertained by angiography and cardiac catheterization in both cases. In each case, aortic valve opening was widened by incision along the fused commissure between the combined left and right coronary cusp on one side, and the noncoronary cusp on the other side. Post-op. pressure gradient between the aorta and left ventricle markedly reduced, in the first case, 50mmHg, and in the 2nd case, 55mmHg.Both patients discharged with good results 2 weeks after open heart surgery.

  • PDF

Evaluation of plasma N-terminal pro-brain natriuretic peptide and troponin I concentrations in dogs with congenital ventricular outflow tract stenosis

  • Kim, Gye-Dong;Suh, Sang-IL;Park, In-Chul;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제56권4호
    • /
    • pp.223-227
    • /
    • 2016
  • This study evaluated the levels of cardiac biomarkers in dogs with either pulmonic stenosis or aortic stenosis and the correlation between biomarkers and the severity of stenosis assessed by the echocardiography. To achieve this study goal, 38 dogs (10 healthy control dogs, 15 dogs with pulmonic stenosis and 13 dogs with aortic stenosis) were examined. The jet velocity and pressure gradient in this study population were measured by echocardiographic estimation, after which the study group was subdivided by the severity of stenosis. The plasma cardiac troponin I (cTnI) and N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured in this study group. The median concentrations of cTnI and NT-proBNP of the disease group were significantly higher than those of the control group, and these increased gradually as stenosis worsened. The severity of stenosis and the concentrations of cTnI and NT-porBNP were also found to be significantly correlated. Finally, the plasma cTnI and NT-proBNP tests were found to beneficial for differentiating clinical patients, predicting the progression of disease, and monitoring the outcome of interventional therapy for stenosis.

기관협착증의 외과적 치료 (Surgical Treatment of Tracheal Stenosis)

  • 조경수
    • Journal of Chest Surgery
    • /
    • 제22권5호
    • /
    • pp.834-838
    • /
    • 1989
  • Tracheal stenosis is being encountered more frequently as ventilatory support and cuffed tubes are increasingly used for treatment of respiratory failure. We experienced 13 cases of tracheal stenosis treated surgically at department of Thoracic and Cardiovascular Surgery, school of medicine, Kyung Hee university during the 4 years. The causes of tracheal stenosis were prolonged endotracheal intubation 5 cases, tracheostomy 3 cases, tracheal tumor 2 cases, thyroid tumor 1 case and congenital double aortic arch 1 case. The methods used to manage the tracheal stenosis were tracheal resection % end to end anastomosis 8 cases, 2 cases of subglottic stenosis were underwent primary laryngotracheal anastomosis, Lt. aortic arch division 1 case, and stent insertion 2 cases. In two cases, who had 6 cm in length of tracheal stenosis, we were underwent tracheal resection k end to end anastomosis with supralaryngeal release procedure. Postoperative courses were uneventful except one case with tracheal tumor.

  • PDF