• 제목/요약/키워드: antigen rapid test

Search Result 92, Processing Time 0.034 seconds

Evaluation of Rapid Diagnostics for Plasmodium falciparum and P. vivax in Mae Sot Malaria Endemic Area, Thailand

  • Chaijaroenkul, Wanna;Wongchai, Thanee;Ruangweerayut, Ronnatrai;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Prompt and accurate diagnosis of malaria is the key to prevent disease morbidity and mortality. This study was carried out to evaluate diagnostic performance of 3 commercial rapid detection tests (RDTs), i.e., Malaria Antigen Pf/Pan$^{TM}$, Malaria Ag-Pf$^{TM}$, and Malaria Ag-Pv$^{TM}$ tests, in comparison with the microscopic and PCR methods. A total of 460 blood samples microscopically positive for Plasmodium falciparum (211 samples), P. vivax (218), mixed with P. falciparum and P. vivax (30), or P. ovale (1), and 124 samples of healthy subjects or patients with other fever-related infections, were collected. The sensitivities of Malaria Ag-Pf$^{TM}$ and Malaria Antigen Pf/Pan$^{TM}$ compared with the microscopic method for P. falciparum or P. vivax detection were 97.6% and 99.0%, or 98.6% and 99.0%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, and Malaria Antigen Pf/Pan$^{TM}$ were 93.3%,98.8%, and 94.4%, respectively. The sensitivities of Malaria Ag-Pf$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method, when PCR was used as a reference method for P. falciparum or P. vivax detection were 91.8%, 100%, and 96.7%, or 91.9%,92.6%, and 97.3%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method were 66.2%, 92.7%, 73.9%, and 78.2%, respectively. Results indicated that the diagnostic performances of all the commercial RDTs are satisfactory for application to malaria diagnosis.

Serological Test of Virus disease of Tussah Silkworm. (작잠농병 Virus의 면역학혈청학적 반응)

  • 임종성
    • Journal of Sericultural and Entomological Science
    • /
    • v.6
    • /
    • pp.42-48
    • /
    • 1966
  • Throughout the studies the following experimental results were obtained and so are summarized here. 1) What caused tussah silkworms terrible disease broken ous all over the Korea in 1965, was examined to be “Inclusion body of virus” through microscope. 2) The examined inclusion bodies are easily stained as purple by seller's staining. 3) The proper speed of centrifugation for the purification of inclusion bodies is 1,000 r. p. m for 10 minutes. 4) It is possible, cleanly resulted, to attempt the “Rapid Agglatination Test & Complement Fixation test” with autigen of inclusion bodies. 5) The Anti-polyhedra rabbit serum from antigen of the dilution of 2${\times}$10$\^$6//l$m\ell$ polyhedra made the Ropid Agglutination test possible even with dilution of 1/8 infected pupa blood(antigen).

  • PDF

Quantitation of Antigen-Antibody Reaction Condition for Development of Fluorescence Image-based CD4 Rapid Test (형광 영상 기반 CD4 신속 검사법 개발을 위한 항원-항체 반응 조건 정량화)

  • Kim, Subin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • CD4+ T-cell count determines the effectiveness for antiretroviral therapy (ART) in patients with human immunodeficiency virus (HIV). Although ART slows the progression of HIV to AIDS, rapid counting of CD4+ T lymphocytes with a drop of patient's blood sample is urgently needed to ensure timely ART treatment in rural areas. Recently point-of-care CD4 testing devices have been developed by using non-flow based imaging cytometer incorporated with a sample cartridge where CD4+ T cells are reacted with fluorescently tagged specific antibodies. Here we conducted an experimental study using a conventional fluorescence microscope-based imaging system to quantitate the interaction of CD4 antibodies with CD4+ T cells at different reaction conditions. We demonstrated that a fast and affordable point-of-care CD4 test is feasible with a far less amount of antibodies and a shorter incubation time compared with a conventional sample preparation protocol for flow cytometry. We also proposed a general method to evaluate and compare the detection limit across different CD4 counting platforms by using fluorescently labelled microbeads for intensity calibration.

Diagnostic value of a dot immunobinding assay for human pulmonary hydatidosis

  • OLUT Ali I.;ERGUVEN Sibel;EMRI Salih;OZUNLU Haluk;AKAY Hadi
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.1 s.133
    • /
    • pp.15-18
    • /
    • 2005
  • The diagnosis of human hydatidosis is primarily made using radiological and serological methods. Radiological methods are generally of low specificity and serological methods lack sensitivity, especially for pulmonary disease. In this study the capabilities of a new rapid test, the hydatid antigen dot immunobinding assay (HA-DIA), which was developed for the diagnosis of pulmonary hydatidosis, were studied and compared with another immunodiagnostic method, indirect hemagglutination (IHA). The study subjects included 18 patients, 9 women, 9 men; range 7 to 63 years; mean 30 years, with surgically proven pulmonary hydatidosis, a control group comprised of 14 patients; viral respiratory infections (1), cirrhosis (2), connective tissue disease (2), taeniasis (3), and 6 healthy donors. We found that the HA-DIA test had a sensitivity of $67\%$ and specificity of $100\%$, and that the IHA test had a sensitivity of $50\%$ and specificity of $100\%$. We conclude that HA-DIA is a simple, rapid, low cost assay that does not require instrumentation and has a higher sensitivity than IHA for the diagnosis of pulmonary hydatidosis.

Expression and diagnostic application of p12 protein of African swine fever virus by recombinant baculovirus (재조합 baculovirus에 의한 아프리카 돼지콜레라바이러스 p12 단백질의 발현과 진단적 적용)

  • Choi, Kang-Seuk;Choi, Cheong-up;Kim, Yong-Joo
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • African swine fever (ASF) is an infectious disease of domestic and wild pigs for which there is no vaccine in the world. A proper surveillance of viral activity and a timely response to ASF outbreaks depend upon the rapid diagnosis of ASF viral infection. Internationally prescribed enzyme-linked immunosorbent assay (ELISA) is a fast, sensitive test routinely used in the diagnosis of the ASF. However, inactivated whole ASF virus antigen used in this test is a tedious to prepare and has a risk of outside exposure of infectious virus by laboratory accident during the preparation. An ASF virus noninfectious recombinant antigen is a safe and easily produced alternative antigen for use in diagnostic assay. We have cloned the ORF O61R gene of the ASF virus to generate a recombinant baculovirus producing the p12 protein in insect cells under control of the polyhedrin promoter as non-fusion protein. When used in an indirect ELISA, the p12 antigen showed reactivity with all known ASF positive pig sera but not with negative pig sera. Our results indicated that the p12 protein would be one of alternative antigens for diagnosis of the ASF.

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

A Rapid Diagnostic Test for Toxoplasmosis using Recombinant Antigenic N-terminal Half of SAG1 Linked with Intrinsically Unstructured Domain of GRA2 Protein

  • Song, Kyoung Ju;Yang, Zhaoshou;Chong, Chom-Kyu;Kim, Jin-Soo;Lee, Kyung Chan;Kim, Tong-Soo;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.503-510
    • /
    • 2013
  • Toxoplasma gondii is an apicomplexan parasite with a broad host range of most warm-blooded mammals including humans, of which one-thirds of the human population has been infected worldwide which can cause congenital defects, abortion, and neonatal complications. Here, we developed a rapid diagnostic test (RDT) for T. gondii infection. Antigenic N-terminal half of the major surface antigen (SAG1) was linked with intrinsically unstructured domain (IUD) of dense granule protein 2 (GRA2). The recombinant GST-GRA2-SAG1A protein was successfully expressed and purified as 51 kDa of molecular weight. Furthermore, antigenicity and solubility of the rGST-GRA2-SAG1A protein were significantly increased. The overall specificity and sensitivity of GST-GRA2-SAG1A loaded RDT (TgRDT) were estimated as 100% and 97.1% by comparing with ELISA result which uses T. gondii whole cell lysates as the antigen. The TgRDT tested with Uganda people sera for field trial and showed 31.9% of seroprevalence against T. gondii antibody. The TgRDT is proved to be a kit for rapid and easy to use with high accuracy, which would be a suitable serodiagnostic tool for toxoplasmosis.

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.1
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

Clinical Usefulness of Rapid Antigen Test on the Diagnosis of Influenza (인플루엔자 진단을 위한 신속 항원검사의 유용성)

  • Kim, Jae Seon;Choi, Hyon Joo;Ahn, Young Min;Hwang, Young Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1348-1353
    • /
    • 2005
  • Purpose : Influenza is a respiratory disease which prevails widely every year and shows high morbidity and mortality among not only chronic invalids and the old, but also among infants and young children. To prevent community-acquired influenza infection, to facilitate prompt antiviral therapy and to avoid unnecessary use of antibiotics, an easy, rapid diagnostic method for the influenza virus is needed. We evaluated a lateral-flow immunoassay(QuickVue Influenza Test), compared to viral culture. Methods : During two consecutive years from Jan. 2004 to June 2004 and from Feb. 2005 to Jan. 2005, 408 patients who were suffering from fever, cough and/or sore throat and myalgia were enrolled in our study. A total of 408 patients were tested with $QuickVue^{(R)}$(Quidel Co., San Diego, USA) influenza rapid antigen test and virus cultures at the same time. Results : Of the 408 patients tested, children who showed positive results at the virus culture numbered 77; among them, 55(71.4 percent) were type A/H3N2 and 22(28.5 percent) were type B. QuickVue influenza test had a sensitivity of 71.4 percent and a specificity of 95.8 percent. The positive and negative predictive values were 79.7 percent and 93.5 percent, respectively. Conclusion : In our study, this test had comparable high sensitivity and high specificity and many advantages, such as being easy to perform and simple to interpret, and showing rapid results. If rapid influenza antigen tests are widely applied in the clinic, we can begin treatment more rapidly and reduce influenza complications and the abuse of antibiotics.

Clinical Analysis of Influenza in Children and Rapid Antigen Detection Test on First Half of the Year 2004 in Busan (2004 상반기 부산 지역에서 유행한 인플루엔자의 임상 역학적 분석 및 인플루엔자 진단에 있어서의 신속 항원 검사법)

  • Choi, So Young;Lee, Na Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • Purpose : Although influenza is one of the most important cause of acute respiratory tract infections in children, virus isolation is not popular and there are only a few clinical studies on influenza and diagnostic methods. We evaluated the epidemiological and clinical features of influenza in children and rapid antigen detection test(QuickVue influenza test) on fist half of the year 2004 in Busan. Methods : From January 2004 to June 2004, throat swab and nasal secretion were obtained and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Influenza viruses were isolated in 79(17.2%) out of 621 patients examined. Influenza virus was isolated mainly from March to April 2004. The ratio of male and female with influenza virus infection was 1.2 : 1 with median age of 4 years 6month. The most common clinical diagnosis of influenza virus infection was bronchitis. There was no difference between influenza A and B infection in clinical diagnosis and symptoms. All patients recovered without severe complication. The sensitivity obtained for rapid antigen detection test (QuickVue influenza test) was 93.6% and the specificity was 80.2%, the positive predictive value 40.8%, the negative predictive value 98.8%. Conclusion : With rapid antigen detection test, it is possible early detection of influenza in children. reduction in use of antimicrobial agent and early use of antiviral agent.

  • PDF