• 제목/요약/키워드: anti-disaster

검색결과 83건 처리시간 0.034초

Human Norovirus Replication in Temperature-Optimized MDCK Cells by Forkhead Box O1 Inhibition

  • Jeong, Eun-Hye;Cho, Se-Young;Vaidya, Bipin;Ha, Sang Hoon;Jun, Sangmi;Ro, Hyun-Joo;Lee, Yujeong;Lee, Juhye;Kwon, Joseph;Kim, Duwoon
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권9호
    • /
    • pp.1412-1419
    • /
    • 2020
  • Human noroviruses (HuNoVs) are a leading cause of gastroenteritis outbreaks worldwide. However, the paucity of appropriate cell culture models for HuNoV replication has prevented developing effective anti-HuNoV therapies. In this study, first, the replication of the virus at various temperatures in different cells was compared, which showed that lowering the culture temperature from 37℃ significantly increased virus replication in Madin-Darby canine kidney (MDCK) cells. Second, the expression levels of autophagy-, immune-, and apoptosis-related genes at 30℃ and 37℃ were compared to explore factors affecting HuNoV replication. HuNoV cultured at 37℃ showed significantly increased autophagy-related genes (ATG5 and ATG7) and immune-related genes (IFNA, IFNB, ISG15, and NFKB) compared to mock. However, the virus cultured at 30℃ showed significantly decreased expression of autophagy-related genes (ATG5 and ATG7), but not significantly different major immune-related genes (IFNA, ISG15, and NFKB) compared to mock. Importantly, expression of the transcription factor FOXO1, which controls autophagy- and immune-related gene expression, was significantly lower at 30℃. Moreover, FOXO1 inhibition in temperature-optimized MDCK cells enhanced HuNoV replication, highlighting FOXO1 inhibition as an approach for successful virus replication. In the temperature-optimized cells, various HuNoV genotypes were successfully replicated, with GI.8 showing the highest replication levels followed by GII.1, GII.3, and GII.4. Furthermore, ultrastructural analysis of the infected cells revealed functional HuNoV replication at low temperature, with increased cellular apoptosis and decreased autophagic vacuoles. In conclusion, temperature-optimized MDCK cells can be used as a convenient culture model for HuNoV replication by inhibiting FOXO1 and providing adaptability to different genotypes.

도시가스 매설이중배관 건전성 향상에 관한 실험적 연구 (An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity)

  • 임형덕
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.

Analytical solution of seismic stability against overturning for a rock slope with water-filled tension crack

  • Zhang, Yanjun;Nian, Tingkai;Zheng, Defeng;Zheng, Lu
    • Geomechanics and Engineering
    • /
    • 제11권4호
    • /
    • pp.457-469
    • /
    • 2016
  • Steep rock slope with water-filled tension crack will happen to overturn around the toe of the slope under seismic loading. This failure type is completely different from the common toppling failure occurring in anti-dipping layered rock mass slopes with steeply dipping discontinuities. This paper presents an analytical approach to determine the seismic factor of safety against overturning for an intact rock mass slope with water-filled tension crack considering horizontal and vertical seismic coefficients. This solution is a generalized explicit expression and is derived using the moment equilibrium approach. A numerical program based on discontinuous deformation analysis (DDA) is adopted to validate the analytical results. The parametric study is carried out to adequately investigate the effect of horizontal and vertical seismic coefficients on the overall stability against overturning for a saturated rock slope under two water pressure modes. The analytical results show that vertically upward seismic inertia force or/and second water pressure distribution mode will remarkably decrease the slope stability against overturning. Finally, several representative design charts of slopes also are presented for the practical application.

소규모 건설현장 떨어짐 사망재해 저감방안 연구 - 비계 및 작업발판 중심 - (Research of the reduction measures for fall accident death in small scale construction sites. - On the Basis of work plate and scaffolding -)

  • 유현동;강경식
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.55-62
    • /
    • 2014
  • During five years (Year 2009~2013), Total victims of 72 %(81,560 people) and those 50.6 %(1,258 people) of death accident occurs in small scale construction site which operate 2 million USD less construction budget. Especially, falling death accident account for 785 people, in the share of 33.2 %(261 people) death disaster takes due to defect of original cause materials. The major safety issues in small scale work place take place while scaffold installation, disassembling, work-plate improper installation or non-professional skills of workers. Furthermore, labor subcontract systems make small construction site shortage of resources. Those workers regard work-plate as unnecessary and consumables supplies. Because of that most of workers use unsafe workplace in most construction site. Therefore, in order to prevent falling accident occurring in small scale work site, government should organize related regulations such as "Work site safety construction method" and then expands education support, financial aid, and sourcing safety supplies for work plate which offer broad variety experiences. Also, introduce certificate solutions for various work plates to improve safety function such as anchoring type method and anti sliding function.

3D stability of pile stabilized stepped slopes considering seismic and surcharge loads

  • Long Wang;Meijuan Xu;Wei Hu;Zehang Qian;Qiujing Pan
    • Geomechanics and Engineering
    • /
    • 제32권6호
    • /
    • pp.639-652
    • /
    • 2023
  • Stepped earth slopes incorporated with anti-slide piles are widely utilized in landslide disaster preventions. Explicit consideration of the three-dimensional (3D) effect in the slope design warrants producing more realistic solutions. A 3D limit analysis of the stability of pile stabilized stepped slopes is performed in light of the kinematic limit analysis theorem. The influences of seismic excitation and surcharge load are both considered from a kinematic perspective. The upper bound solution to the factor of safety is optimized and compared with published solutions, demonstrating the capability and applicability of the proposed method. Comparative studies are performed with respect to the roles of 3D effect, pile location, pile spacing, seismic and surcharge loads in the safety assessments of stepped slopes. The results demonstrate that the stability of pile reinforced stepped slopes differ with that of single stage slopes dramatically. The optimum pile location lies in the upper portion of the slope around Lx/L = 0.9, but may also lies in the shoulder of the bench. The pile reinforcement reaches 10% universally for a looser pile spacing Dc/dp = 5.0, and approaches 70% when the pile spacing reaches Dc/dp = 2.0.

콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구 (A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test)

  • 민세홍;선주석;김상철;최용묵;이석기
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.106-111
    • /
    • 2012
  • 본 연구에서는, 건축 외장재로 많이 사용되고 있는 외단열시스템에 대해 방염 효과를 확인하기 위하여 콘칼로리미터 실험을 적용하였다. 실험 결과, 방염제의 도포 형태나 농도에 따라 초기 착화 시점을 지연하는데 효과가 있었으나, 외벽 수직화재 발생 시 외단열시스템의 방염처리는 화재에 영향을 미치지 못할 것이라는 것을 확인하였다. 또한, 외단열시스템에 사용하는 고밀도와 저밀도 스티로폼의 밀도차에 의한 화재에 미치는 영향은 차이가 없음을 확인하였다. 실험 시 외장재의 착화는 40초 전후로 발생하였으며, 방출열량도 100초 이내에 약 90 %가 발생하는 것으로 나타나 다른 외벽재료와 비교하여 초기 화재 확산이 매우 빠름을 알 수 있었다. 외단열시스템 외장재 화재로 인한 화재 확산을 방지하기 위해서는 법적으로 외단열시스템의 적용 시 건물의 용도별로 사용을 제한하거나 화염전파를 차단할 수 있는 수직외벽 구획 등의 대책이 시급히 요구된다.

부력가방의 익사사고 저감성능 분석 (Performance Analysis on the Reduction of Drowning Accident Using Buoyancy Bag)

  • 최광원;조원철;이태식
    • 한국재난관리표준학회지
    • /
    • 제3권2호
    • /
    • pp.33-39
    • /
    • 2010
  • 본 연구는 부력가방의 익사사고 저감성능 분석에 관한 연구로서, 시민들은 레저 활동 및 물놀이 활동 시 부주의로 인하여 익사사고가 발생할 경우 119구조대나 타인의 구조활동만으로는 사고자 생존율이 저조하다고 할 수 있다. 이에 따라 수상 전문가들은 부력제품을 활용하여 익사사고를 줄이고, 시민은 일상용 휴대가방에 안전관리 기능을 추가한 부력가방을 평상시에 차량안이나 개인이 직접 휴대함으로써 본인의 생명과 위급한 상황에 봉착한 타인을 신속하게 구조할 수 있는 구명용 도구로 활용할 수 있도록 하였다. 본 연구를 통하여 개발된 부력가방은 편리성 안전성 지속성의 3가지 방재특성을 지니고 있으며, 서류 물품 등을 보관하는 편리성, 성인 1명 기준인 90 kg 무게를 띄울 수 있는 부력재를 내피 분산방식으로 처리한 안전성, 그리고 방수원단 및 방수지퍼 사용으로 장시간 안전을 유지하는 지속성 등을 갖춘 제품이다. 성능분석 결과 부력가방이 다른 구조장비와 비교해도 현장 간접 구조장비로 사용하는데 아무런 문제점이 없다는 것을 알 수 있었으며 부력성능과 디자인적인 측면만 더 보완하면 국민의 귀중한 생명을 보호하는데 많은 기여를 할 수 있을 것이다.

  • PDF

라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구 (Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering)

  • 이건호;임우섭;김시국
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.27-38
    • /
    • 2016
  • 본 논문은 현재 국외기술에 의존하고 있는 광센서 선형감지기를 이용한 화재감지시스템인 분산온도감지(DTS) 시스템을 국산화 기술로 개발하기 위한 연구이다. 이에 본 연구에서는 광섬유 내에서 발생되는 빛의 역산란광 중 온도감지에 주로 사용되는 라만산란광의 전기적 신호파형을 오실로스코프를 이용하여 분석하였다. 측정결과 Stokes 신호파형은 온도가 상승해도 변화량이 거의 없었으나, 온도에 민감한 anti-Stokes 신호파형은 상대적으로 그 값이 증가하는 것을 확인할 수 있었다. 그리고 라만산란광을 이용하여 화재를 감지할 수 있는 광중계기 및 광수신기로 구성된 광센서 선형 화재감지시스템인 K-DTS 시스템을 개발하였다. 개발된 K-DTS 시스템에 대하여 차동식 및 정온식 감도시험기를 이용하여 차동식 및 정온식 감지기로서의 감도시험을 진행해 본 결과 형식승인 기준을 만족하고 있는 것을 확인할 수 있었다. 또한, 개발된 K-DTS 시스템의 성능평가를 위해 국외에서 수입되어 가장 많이 사용되고 있는 S-DTS 시스템과 성능비교실험을 진행하였다. 모형터널을 이용한 성능실험결과 화재감지위치 및 화재온도 측정에서 유사한 성능을 나타내는 것을 확인할 수 있었다.

망 시설 유무에 따른 배 과원의 미기상 분석 (Micrometeorology Analysis of Pear Orchard with Anti-insect Nets for Non-bagged Cultivation)

  • 유석철;최진호;이한찬;이욱용
    • 생물환경조절학회지
    • /
    • 제28권2호
    • /
    • pp.150-157
    • /
    • 2019
  • 본 연구는 방충망 시설이 생육환경에 미치는 영향을 구명하기 위한 기초자료로 활용되도록 무봉지 재배를 위한 망 시설 테스트베드를 설치하고 온도, 습도, 풍속 및 일사량을 수집한 기상자료를 분석하여 망 시설 내 외부의 미기상 특성을 확인하고자 하였으며, 기상자료를 분석한 결과는 다음과 같다. 온도와 습도의 경우 망의 피복 여부에 따라 $0.2^{\circ}C$, 3.5~4.7%의 차이가 발생하였으며 실험구 대비 대조구에서 수분부족분이 증가하는 경향을 보였다. 외부와 망 시설 내부에서 일사 투과율은 격자크기에 따라 큰 차이를 나타냈다. 특히 격자 크기가 2mm인 경우 외부와의 일사 투과율이 최대 50%정도까지 감소하는 것으로 나타났으며, 이는 과실 생육에 큰 영향을 미칠 수 있기 때문에 격자 크기 선택에 있어서 고려해야할 요소로 판단된다. 태풍 솔릭 내습시의 망 시설 내?외부의 풍속을 비교한 결과, 7 m/s이상의 고풍속일 때 격자 크기가 4 mm 망 시설은 40% 이상, 2 mm의 경우 50% 이상의 풍속 감소율을 보였다. 또한 풍속저감 효과로 인한 낙과 피해도 현저하게 감소하는 것으로 나타났다. 이러한 연구결과는 망 피복에 따른 과수의 생육환경에 미치는 영향과 최근에 잦은 이상기상 발생으로 망 시설을 적용한 이상기상 피해저감 효과 등의 기초자료로 활용될 수 있을 것으로 판단된다.

Incidence and Predictors of Hand-Arm Musculoskeletal Complaints among Vibration-exposed African Cassava and Corn Millers

  • Mbutshu, Lukuke Hendrick;Malonga, Kaj Francoise;Ngatu, Nlandu Roger;Kanbara, Sakiko;Longo-Mbenza, Benjamin;Suganuma, Narufumi
    • Safety and Health at Work
    • /
    • 제5권3호
    • /
    • pp.131-135
    • /
    • 2014
  • Background: Cassava and corn milling is a growing small-scale enterprise in Africa. We aimed to determine the incidence of hand-arm musculoskeletal complaints among vibration-exposed Congolese cassava and corn millers in the previous 12 months. Methods: A cross-sectional study was conducted, prior to a follow-up study, from March to May 2013 among cassava/corn millers in Lubumbashi, Democratic Republic of Congo, in which 365 millers age-matched to 365 civil workers anonymously answered a questionnaire. Results: Overall incidence of hand-arm musculoskeletal complaints was 25.8% in millers (vs. 5.2% in civil workers; p < 0.001). The risk of experiencing musculoskeletal symptoms was seven times higher in millers [vs. civil workers; odds ratio (OR) = 7.10; 95% confidence interval (CI): 4.03-12.50; p < 0.0001]; 2.4 times higher in smoking millers (vs. smoking civil office workers; OR = 2.36; 95% CI: 1.42-3.88; p < 0.001); 3.6 times higher in millers with longer daily exposure (> 8 hours; vs. those working ${\leq}8$ hours; OR = 3.56; 95% CI: 1.93-3.61; p = 0.026); and 7.4 times higher in young millers (vs. older millers, OR = 7.39; 95% CI: 1.29-75.52; p < 0.001). Smoking, number of cigarettes, and daily exposure duration were positively correlated with musculoskeletal complaints. Conclusion: This study revealed a relatively high incidence of musculoskeletal complaints among African cassava and corn millers. The use of anti-vibration protective equipment and the regulation of this hazardous occupation may reduce the burden of musculoskeletal disorders in millers.