• 제목/요약/키워드: anodic oxidation implant surface

검색결과 21건 처리시간 0.023초

양극산화 표면처리한 티타늄 임플랜트를 난소절제한 백서 경골에 매식 후 주위 골형성에 관한 연구 (THE BONE FORMATION AROUND ANODIC OXIDIZED TITANIUM IMPLANTS IN THE TINBIAE OF OVARECTOMIZED RATS)

  • 박성환;정석영;이재열;김규천;신상훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.306-318
    • /
    • 2008
  • Anodic spark deposition method(ASD) surface treated titanium implant possesses a considerable osteoconductive potential that promoting a high level of implant osseointegration in normal bone. The purpose of this study was to observe the ASD implant's osseointegration in the osteoporosis-induced animal model. Twenty four rats, 10 weeks of age, were ovarectomized and 5 weeks later divided into two groups : ASD implant group and control implant group. Titanium screw implants (diameter; 2.0 mm, length, 3.5 mm; pitch-height, 0.4 mm) were designed for this study. Experimental implants were ASD treated and no treatment on control implants. ASD implants and control implants were placed in to left tibiae of rats. The rats were sacrificed at different time interval(1, 2, 4 and 8 weeks after implantation) for histopathologic observation and immunohisto-chemistrical observation, with collagen type Ⅰ, fibronectin, integrin ${\alpha}_2{\beta}_1$ and integrin ${\alpha}_5{\beta}_1$ antibodies. The results obtained from this study were as follow: 1. Histopathologic findings, overall tissue response and the pattern of bone formation in both groups were similar. In ASD group, more newly formed bone was seen at 1 week and 2weeks than control group. 2. The levels of type Ⅰ collagen and fibronectin expression were the most abundant at 2weeks and decreased gradually in both groups. Fibronectin and type Ⅰ collagen expression in ASD group were stronger than control group but no significance. 3. The levels of integrin ${\alpha}_2{\beta}_1$ and Integrin ${\alpha}_5{\beta}_1$ expression were most abundant at 2 weeks and decreased gradually in both groups. No significant difference was observed in both groups. From this results, anodic oxidized titanium implants were more advantages in early stage of bone formation than control group, but have no significance in tissue responses and late bone formations. It could be stated that although anodic oxidized titanium implant possesses considerable osteoconductive potential but in osteoporotic bone condition dental implant procedure should performed after improving or treating the osteoporotic bone condition.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

RESONANCE FREQUENCY ANALYSIS OF IMPLANTS WITH ANODIZED SURFACE OXIDES

  • Choi Jeong-Won;Heo Seong-Joo;Chang Ik-Tae;Koak Jai-Young;Han Jong-Hyun;Kim Yong-Sik;Lee Seok-Hyung;Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.294-300
    • /
    • 2004
  • The present experimental study was designed to address two issues. The first was to investigate whether oxidation voltage of titanium implants influenced bone tissue responses after an in vivo implantation. The second aim was to investigate secondary stability change after 1 to 3months period. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of $3-15{\mu}m$. The micro structure revealed pore sizes of $1-3{\mu}m$, the crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. Bone tissue responses were evaluated by resonance frequency measurements that were undertaken 1 to 3months after insertion in the rabbit tibia. It was concluded that no statistical difference of RFA values was found between the groups, RFA gains after Imonth and 3months were calculated.

임플랜트 표면처리가 생체활성에 미치는 영향 (EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT)

  • 이호진;송광엽;윤태호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

성견에서 즉시 임플란트 식립시 국내 임플란트에서의 골 유착반응에 관한 연구 (Study on Osseointegration of the Immediate Placement Using Korean Implant Systems in Beagle Dog)

  • 서정윤;이욱재;이종철;신미란;김윤상;피성희;신형식;유형근
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.223-236
    • /
    • 2007
  • This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and $Atlas^{(R)}$ Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-l Implant(diameter: 3.5mm, length: IOmm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.

아파타이트의 형성에 미치는 티타늄의 표면처리 효과 (Effect of Surface Treatment of Titanium on the Formation of Apatite Crystal)

  • 정회웅;원대희;이민호;배태성
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.231-232
    • /
    • 1998
  • The purpose of this study was to examine whether the precipitation of calcium phosphate on titanium surface was affected by surface modification. To improve the bone conductivity, of titanium, samples were devided into 4 groups. Group 1 was immersed in 5M-NaOH solution at $60^{\circ}C$ for 24 hours. Group 2 was immersed in 5M-NaOH solution at $60^{\circ}C $ for 24 hours and heat-treated at $600^{\circ}C$ for 1 hour. Group 3 was anodized in Hanks' solution at 1V, $25^{\circ}C$ for 1 hour. Group 4 was anodized in Hanks' solution at 5V, $80^{\circ}C$ for 5 minutes. And then, all specimens were immersed in the MEM Eagle's medium whose composition was similar to that of extracellular fluid for 30 days. The precipitation of the calcium phosphate on implant surface was increased by the immersion in the NaOH solution, and more highly accelerated by heat treatment at $600^{\circ}C$. The precipitation of the calcium phosphate on titanium implant was increased with the treatment of the anodic oxidation in Hanks' solution at 5V, $80^{\circ}C$.

  • PDF

임플란트 표면의 Ca-P 코팅 방법이 MG63 골모유사세포 반응에 미치는 영향에 대한 in vitro 연구 (The effect of Ca-P coatings of anodized implant surface on response of osteoblast-like cells in vitro)

  • 김일연;정성민;황순정;신상완
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.376-384
    • /
    • 2009
  • 연구목적: 본 연구에서는 양극산화 임플란트 표면에 서로 다른 두 가지 방법, Ion beam-assisted deposition (IBAD)법과 Sol-gel법으로 Ca-P 코팅한 임플란트 시편에 골모세포를 배양하였을 때 세포의 증식, 분화, 형태에 어떠한 영향을 미치는지 조사하고자 한다. 연구재료 및 방법: 지름 10 mm, 두께 2 mm 인 상업용 순수 titanium grade IV 재질의 디스크를 제작하였고, 모든 시편은 acetone, 70% ethanol, 증류수에서 각각 10분씩 세척 후 건조하였다. 모든 표면은 300 V의 constant voltage하에서 양극 산화 (anodized)시킨다. 실험군은 양극산화 임플란트 표면에 각각 IBAD법과 Solgel법으로 Ca-P 코팅하였다. 각 표면의 미세표면 거칠기(Ra)를 측정하였고, SEM을 통해 표면의 형상을 관찰하였다. 골모세포을 배양한 후 각 표면군의 세포 증식, ALP 활성도 및 RT-PCR를 통한 골세포 분화 능력 검증을 하였으며, SEM을 통해 세포의 형상도 확인하였다. 통계분석은 SPSS (version 12.0) 프로그램을 이용하여 Kruskal-Wallis Test로 각 군의 유의성을 검증하였다 ($\alpha$=0.05). 결과: IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면보다 표면 거칠기 (Ra) 값이 더 크게 나타났다 (P<.05). IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면 보다 세포 증식이 더 활발하고 골세포 조기 분화 정도를 확인 할 수 있는ALP 활성도 또한 더 높게 나타났다 (P<.05). SEM 관찰 결과IBAD법으로 Ca-P 코팅한 표면에 골모세포들이 친화성을 띄면서 안정적으로 부착되었다. 결론: IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면보다 더 우수한 세포 반응을 보였다. IBAD법으로 Ca-P 코팅한 표면의 세포들은 증식이 잘 이루어지고 잘 분화된 골모세포 형상을 보이고 ALP 활성도 또한 높아 골 형성을 증가시켜 높은 골-임플란트 접촉을 보일 것이다.

Surface characteristics and bioactivity of an anodized titanium surface

  • Kim, Kyul;Lee, Bo-Ah;Piao, Xing-Hui;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • 제43권4호
    • /
    • pp.198-205
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse $MC_3T_3-E_1$ cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide ($TiO_2$) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized $TiO_2$ surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

양극산화에 의한 티타늄 산화막의 표면 특성 및 생체 활성에 관한 연구 (SURFACE CHARACTERISTICS AND BIOACTIVITY OF ANODICALLY OXIDIZED TITANIUM SURFACES)

  • 이상한;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.85-97
    • /
    • 2007
  • Statement of problem: Recently, anodic oxidation of cp-titanium is a popular method for treatment of titanium implant surfaces. It is a relatively easy process, and the thickness, structure, composition, and the microstructure of the oxide layer can be variably modified. Moreover the biological properties of the oxide layer can be controlled. Purpose: In this study, the roughness, microstructure, crystal structure of the variously treated groups (current, voltage, frequency, electrolyte, thermal treatment) were evaluated. And the specimens were soaked in simulated body fluid (SBF) to evaluate the effects of the surface characteristics and the oxide layers on the bioactivity of the specimens which were directly related to bone formation and integration. Materials and methods: Surface treatments consisted of either anodization or anodization followed thermal treatment. Specimens were divided into seven groups, depending on their anodizing treatment conditions: constant current mode (350V for group 2), constant voltage mode (155V for group 3), 60 Hz pulse series (230V for group 4, 300V for group 5), and 1000 Hz pulse series (400V for group 6, 460V for group 7). Non-treated native surfaces were used as controls (group 1). In addition, for the purpose of evaluating the effects of thermal treatment, each group was heat treated by elevating the temperature by $5^{\circ}C$ per minute until $600^{\circ}C$ for 1 hour, and then bench cured. Using scanning electron microscope (SEM), porous oxide layers were observed on treated surfaces. The crystal structures and phases of titania were identified by thin-film x-ray diffractmeter (TF-XRD). Atomic force microscope (AFM) was used for roughness measurement (Sa, Sq). To evaluate bioactivity of modified titanium surfaces, each group was soaked in SBF for 168 hours (1 week), and then changed surface characteristics were analyzed by SEM and TF-XRD. Results: On basis of our findings, we concluded the following results. 1. Most groups showed morphologically porous structures. Except group 2, all groups showed fine to coarse convex structures, and the groups with superior quantity of oxide products showed superior morphology. 2. As a result of combined anodization and thermal treatment, there were no effects on composition of crystalline structure. But, heat treatment influenced the quantity of formation of the oxide products (rutile / anatase). 3. Roughness decreased in the order of groups 7,5,2,3,6,4,1 and there was statistical difference between group 7 and the others (p<0.05), but group 7 did not show any bioactivity within a week. 4. In groups that implanted ions (Ca/P) on the oxide layer through current and voltage control, showed superior morphology, and oxide products, but did not express any bioactivity within a week. 5. In group 3, the oxide layer was uniformly organized with rutile, with almost no titanium peak. And there were abnormally more [101] orientations of rutile crystalline structure, and bonelike apatite formation could be seen around these crystalline structures. Conclusion: As a result of control of various factors in anodization (current, voltage, frequency, electrolytes, thermal treatment), the surface morphology, micro-porosity, the 2nd phase formation, crystalline structure, thickness of the oxide layer could be modified. And even more, the bioactivity of the specimens in vitro could be induced. Thus anodic oxidation can be considered as an excellent surface treatment method that will able to not only control the physical properties but enhance the biological characteristics of the oxide layer. Furthermore, it is recommended in near future animal research to prove these results.

이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구 (On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material)

  • 김성원;조인호
    • 대한치과보철학회지
    • /
    • 제52권1호
    • /
    • pp.9-17
    • /
    • 2014
  • 연구 목적: 본 연구에서는 외과적으로 형성한 골 결손부에 이종골 이식과 함께 식립한 지르코니아 임플란트의 골유착에 대한 기계적 안정성과 조직학적 반응을 타이타늄 임플란트와 비교하고자 하였다. 연구 재료 및 방법: 6마리 돼지의 경골에 인위적으로 형성한 골 결손 부위에 대조군인 18개의 상용 타이타늄 나사형 임플란트와 실험군인 18개의 샌드블라스팅한 지르코니아(Y-TZP) 나사형 임플란트를 각각 식립하고 차폐막을 이용하여 이종골을 이식하였으며 1주, 4주, 12주후에 각각 2마리씩 희생시켜 조직 시편을 제작하였다. 식립 직후와 식립 1주, 4주, 12주 후에 각각 페리오테스트를 이용하여 임플란트의 안정성을 측정하였고, 광학현미경으로 조직학적 관찰과 조직계측학적 분석을 하였으며 주사전자현미경으로 임플란트의 표면 특성과 골-임플란트 계면을 관찰하였다. 결과: 페리오테스트를 이용한 임플란트 안정성 분석 결과, 대조군과 실험군 사이에 유의한 차이가 없었고, 조직학적 분석 결과, 각 군 모두 4주에 이식골의 재흡수와 조골세포의 활발한 활동에 의해 신생골이 형성되기 시작하였다. 골-임플란트 접촉률 분석 결과, 대조군과 실험군 사이에 유의한 차이가 있었으며(P<.05), 특히 4주와 12주에서 실험군과 대조군 사이에 2시점에서 유의한 차이를 보였다(P<.05). 골 면적률 분석 결과, 대조군과 실험군 사이에 유의한 차이가 없었다. 주사전자현미경 관찰 결과, 대조군은 균일한 다공성의 거친 표면을 나타냈고 실험군은 무정형 입자들이 불규칙하게 산재된 표면을 보여 주었다. 각 군 모두 4주에 임플란트 표면과 골 조직 사이에 빈 공간이 관찰되었고 12주에는 일부 공간에서 골 조직으로 채워진 양상을 보였다. 결론: 차폐막을 이용한 이종골 이식을 동반하는 경우 본 실험에 사용된 지르코니아 임플란트의 골-임플란트 접촉률은 양극산화 표면처리를 한 타이타늄 임플란트에 크게 미치지 못하므로 지르코니아 임플란트의 실용화를 위해서는 표면 처리 방법 등에 대한 지속적인 연구를 통한 개선이 필요하다고 사료된다.