• 제목/요약/키워드: angular stability

검색결과 207건 처리시간 0.019초

요통 환자와 정상인의 자세에 따른 체간 위치 오류 비교 (The Comparison of Trunk Repositioning Errors in Individuals with and without Low Back Pain at Different Postures)

  • 육군창;한진태;신현숙;이호건;박래준
    • 대한물리의학회지
    • /
    • 제3권2호
    • /
    • pp.63-74
    • /
    • 2008
  • Purpose : The purpose of this study was to compare trunk repositioning errors between subjects with and without low back pain in sitting and standing. Methods : Total 81 participants were recruited who consisted of 41 subjects with low back pain and 40 normal subjects. The subjects were instructed to replicate the predetermined target positions of the trunk toward upright and $30^{\circ}$ flexion in sitting and standing. During each of movement, digital inclinometer was used to measure the angular movement of $T_{12}$ spinal process. Repositioning error was calculated as the absolute difference between the predetermined target positions and replicated target positions. Results : In subjects with low back pain, upright repositioning error was $1.26^{\circ}{\pm}0.14^{\circ}$ in sitting and $1.55^{\circ}{\pm}0.24^{\circ}$ in standing, and $30^{\circ}$ flexion repositioning error was $3.23^{\circ}{\pm}0.33^{\circ}$ in sitting and $5.50^{\circ}{\pm}0.50^{\circ}$ in standing. In subjects without low back pain, upright repositioning error was $1.38^{\circ}{\pm}0.15^{\circ}$ in sitting and $1.67^{\circ}{\pm}0.18^{\circ}$ in standing, and flexion repositioning error was $2.61^{\circ}{\pm}0.28^{\circ}$ in sitting and $3.70^{\circ}{\pm}0.52^{\circ}$ in standing. It was demonstrated that flexion repositioning error increased significantly in standing position. In subjects with low back pain, $30^{\circ}$ flexion repositioning error was significantly higher in standing than in sitting. Conclusion : The repositioning error of subjects with low back pain increased during flexion and it implies that some aspects of proprioception are decreased in subjects with low back pain. Therefore, it will be emphasis that a clinical trial to increase the trunk flexion stability of subjects with low back pain in standing.

  • PDF

압착되어 회전하는 강체/변형 롤의 동적 특성에 관한 수치해석 연구 (A Numerical Study on Dynamic Characteristics of Counter-Rotating Rigid/Deformable Rolls in Press Contact)

  • 이문규;이상혁;허남건;서영진;김인철;이성진
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.869-876
    • /
    • 2011
  • 동적 특성에 영향을 받는 롤 코팅의 평형적인 두께 예측과 불안정성을 분석함은 중요하다. 본 연구에서는 강체/변형롤 사이에서 생성되는 마이크로 코팅액의 두께를 예측하기에 앞서 압착되어 회전하는 두 롤 사이에 발생하는 접촉 압력의 분포와 변형롤의 변형 형상을 예측하고자 한다. 또한 변형롤의 재료상수와 롤의 속도 및 마찰계수 그리고 압착 크기 등의 변수들에 대한 접촉압력분포를 수치적인 방법으로 측정하여 유효한 변수들의 영향을 분석하고자 한다. 수치해석 방법으로는 유한요소법을 사용하였고 두 롤을 모델링하여 변형롤에 고무물성치를 초탄성체 모델로 가정하여 일반적으로 사용되는 Mooney Rivlin 계수를 사용하였고 40~80rpm 사이의 속도로 회전할 때 접촉 형상 및 압력분포를 분석하였다. 접촉형상의 경우 압착정도에 따라 변하고 그외 변수들에는 영향을 받지 않고 접촉압력의 경우 변형롤의 물성치와 압착정도에 의해 주요한 영향을 받고 속도 및 마찰계수에는 영향을 받지 않음을 알 수 있다.

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제23권2호
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

8주간의 어깨 강화 운동이 요양보호사들의 어깨 근력에 미치는 영향 (The Effect of an 8-week Shoulder Strengthening Exercise on Shoulder Muscle Strength of Caregivers)

  • 신재욱;이승민;정대윤;김동인;박재성;이병수;송세희;박이대;김문정;김노용;이광훈;김재용
    • PNF and Movement
    • /
    • 제16권1호
    • /
    • pp.43-50
    • /
    • 2018
  • Purpose: This study examined the effects of a shoulder-strengthening exercise on muscle strength of shoulder flexors and extensors of caregivers. Methods: The study consisted of 19 caregivers (2 males and 17 females) employed by Medical Center B. All the participants took part in an 8-week shoulder muscle strengthening exercise, based on previous studies. In the first week, the subjects took part in a stretching exercise enhance the range of motion. In the second week, they participated in an exercise aimed at improving shoulder blade stability. From the third to seventh weeks, a resistance exercise of different intensities was applied in a phased manner. Finally, in the eight week, the subjects took part in plyometric exercise. Peak torque, average power, and total work of shoulder flexors and extensors in both sides were measured before and after the exercise at an angular speed of 120deg/sec using an isokinetic device. Wilcoxon's singed-ranks test was conducted to analyze differences in muscle strength before and after the intervention. Results: After the exercise, there was a significant improvement in peak torque and average power of flexors of the right arm. After the exercise, peak torque, total work, and average power showed a significant improvement in the flexors of the left arm (p<0.05). However, there was no statistically significant difference in extensor muscle strength in either arm after the exercise. Conclusion: Shoulder flexors of caregivers are utilized frequently in the workplace. Implementation of extensor-strengthening exercises, in addition to flexor-strengthening exercises, can contribute to reducing the incidence rate of shoulder injuries among caregivers.

파동방정식 수치해의 일관성에 관한 연구 (A Study on Consistency of Numerical Solutions for Wave Equation)

  • 편석준;박윤희
    • 지구물리와물리탐사
    • /
    • 제19권3호
    • /
    • pp.136-144
    • /
    • 2016
  • 탄성파 자료의 역산은 파동방정식에 기초하고 있으므로 파동방정식의 해를 정확하게 구하는 것이 가장 중요하다. 특히, 전파형역산은 파동장 전체를 이용하기 때문에 정문제에 해당하는 모델링이 정확하게 이루어져야 신뢰할 수 있는 결과를 얻게 된다. 파동방정식의 수치해를 구하는 대표적인 기법인 유한차분법과 유한요소법은 해의 수렴성을 보장할 수 있어야 하는데, 해의 수렴성은 이론적으로 일반화된 증명이 되어 있으나 실제 문제에 적용할 경우 일관성과 안정성을 분석해야 한다. 모델링 결과의 일관성은 송신원 함수의 구현이 매우 중요한 부분인데, 유한차분법은 디랙 델타 함수(Dirac delta function)를 나타낼 때 격자 간격으로 표준화된 싱크 함수(sinc function)를 사용해야 하는 반면 유한요소법은 격자 간격에 관계없이 기저함수 값을 사용하면 된다. 주파수 영역 파동방정식을 사용할 경우 송신 파형 함수의 스펙트럼을 정확하게 표현하기 위해 샘플링 이론으로 정의되는 시간 간격보다 더 조밀한 샘플링 간격을 사용하고 나이퀴스트(Nyquist) 주파수보다 더 높은 주파수를 최대 주파수로 사용해야 한다. 또한, 복소 각주파수를 사용하는 경우 감쇠 파동방정식을 만족하기 위해서는 송신 파형 함수를 먼저 감쇠한 후 사용해야 한다. 이러한 요건들이 모두 만족되었을 때 신뢰할 수 있는 역산 알고리즘 개발이 가능하다.

12주의 어깨 안정성 회복 프로그램이 견관절 불안정성 야구선수의 관절가동범위, 근력에 미치는 영향 (Effect of a 12-week Shoulder Stability Rehabilitation Program on the Range of Motion and Muscle Strength of Baseball Players with Shoulder Instability)

  • 윤진호;오재근;송기재
    • 한국융합학회논문지
    • /
    • 제12권10호
    • /
    • pp.277-286
    • /
    • 2021
  • 이 연구는 12주간 재활 운동프로그램이 어깨 불안정성을 가진 고등학교 야구선수들의 관절가동범위와 근력에 미치는 효과를 알아보기 위해 실시하였다. 어깨 불안정성이 있는 것으로 판명된 재활 운동군 12명과 정상 운동군 13명을 선정하였다. 12주간 재활운동 참가 전·후 내·외회전 관절가동범위는 공변량분석(ANCOVA)을 실시하였으며, 등속성 근력은 이원변량 분석(two-way ANOVA)을 실시하였으며, 통계적 유의수준은 p<.05로 설정 하였다. 관절가동범위는 불안정이 있는 우위측과 비-우위측 어깨의 경우 재활운동 전·후 내회전 ROM이 유의하게 증가했으며, Total ROM의 경우 불안정이 있는 우위측 어깨에서 재활운동 후 유의하게 증가했다. 등속성 근력의 경우 재활운동 후 내회전 근력이 각속도 180°/sec에서 유의하게 개선되었다. 본 연구 결과를 요약하면 12주간 재활운동 프로그램이 어깨 불안정성 환자의 ROM, 근력 개선에 효과적인 것으로 나타났다. 하지만 제한적 결과에 미루어 재활기간의 연장을 전제로 한 추가적 연구가 필요할 것으로 생각된다.

경상남도 일광의 각력파이프형 구리(Cu)광상에서 산출되는 전기석의 지구화학 (Geochemistry of tourmalines in the Ilgwang Cu-W breccia-pipe deposit, Southeastern Gyeongsang Basin)

  • 양경희;장주연
    • 암석학회지
    • /
    • 제11권3_4호
    • /
    • pp.259-270
    • /
    • 2002
  • 경상남도 일광지역의 각력파이프형 구리(Cu)광상은 화강암질암 성분의 암주내에 배태되어 있으며, 모암인 화강암질암은 변질되어 있다. 암흑색의 전기석은 각력파이프를 중심으로 교대 후광을 형성하면서, 석영, 황동석, 유비철석, 자류철석, 방연석, 반동석등과 함께 각력파이프내의 모암인 화강암질암 각력들사이의 기질부를 충전하면서 광맥을 형성하거나, 모암인 장석, 흑운모를 치환교대하면서 산출된다. 각력내(광맥)에서 형성된 전기석은 조립에서 세립질의 자형으로, 침상 내지 깃털 모양으로 산출되며, 다색성 체계는 대체로 짙은 청색과 녹색을 나타낸다. 변질된 모암에서 산출되는 전기석은 타형이며, 등립질의 이차 (secondary) 석영과 함께 방사상의 연정을 이루는 것이 특징적으로 관찰된다. 전기석은 Fe성분이 풍부한, 흑색의 스코올(schorl)(80mol% schorl relative)이며, 비교적 단순한 화학조성을 갖는다. 전기석의 누대구조에 따른 조성 변화는 전기석결정 후기단계에 Fe와 Ca 성분이 증가했음을 나타낸다. 이러한 화학성분의 변화는 Ca에 의한 Na치환, Fe$^{3+}$ 에 의해 Al이 치환되어진 우바이트(uvite)치환(Ca(Fe,Mg)NaAl$_{-1}$)과 페리스코올(ferrischorl)치환 (Fe$^{3+}$ Al$_{-1}$)에 의한 것으로 해석된다. 페리스코올치환이 있었다는 것은 전기석을 침전시킨 열수의 산화상태(oxidation state)가 높아진 것을 반영한다. 이러한 높아진 산화환경은 열수의 비등에 의해 H$_2$ 성분이 열수에서 제거되어져 형성되어졌다. 또한 열수의 비등에 의한 산성(acidic) 휘발성성분 제거는 열수의 pH를 높여 경제성 있는 황화광물의 형성을 용이하게 했다 일광전기석의 산출상태와 지구화학적 특성은 이곳의 전기석은 마그마에서 용리되어진 열수가 각력파이프를 통해 대규모로 이동되어 형성된 생산물이며, 마그마에서 산성성분의 유체가 용리되어 산성열수체계를 형성하고 난 후, 전기석의 침전이 시작되었음을 보여준다 광화대와 변질대를 형성한 일광의 열수체계는 마그마(orthomagmatic), 심부(hypogene) 기원의 열수에 의해 형성되어졌음을 나타낸다.