• Title/Summary/Keyword: angled tube method

Search Result 8, Processing Time 0.027 seconds

Study on the Erythrocyte Sedimentation Rate by Angled Tube Method during Pregnant Period in Holstein (Holstein의 임신기간별 경사시험관법에 의한 적혈구 침강율 연구)

  • 신종욱;김형욱
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.8-12
    • /
    • 1999
  • The erythrocyte sedimentation rate (ESR) test could be applied well in clinic of men, horses or dogs. But the ESR test was not applied to clinic ruminants except for buffaloes since it was too low measure. To overcome this problem angled tube method was developed. This method was found to be useful for making diagnosis and prognosis. The results were summarized as follows. 1. In the early pregnancy condition, corrected ESR did not changed when compared with normal valures. 2. In the middle pregnancy condition, corrected ESR was increased when compeared with normal valures. 3. In the latter pregnancy condition, corrected ESR was increased when compeared with normal valures. 4. After parturition condition, corrected ESR did not changed when compeared with normal valures.

  • PDF

Studies on Erythrocyte Sedimentation Rate Test by Angled Tube Method in Cattle Diseass (우질병에 있어서 경사시험관법에 의한 적혈구침항율에 관한 연구)

  • Shin Jong-uk
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.579-583
    • /
    • 1994
  • In the present studies, samples of blood were taken from 24 Holstein cattle over 2 years old. By using the angled tube method the normal ESR values were determined in cattle under various diseases. The results obtained were summarized as follows ; The standardized ESR/hr using 45$^{\circ}$ angled capillary tubes were 19.0% in case of necrotic mastitis, 23.0% in nephritis, 12.2% in anemia and 4.2% in diarrhea. And the ESR was increased from some necrotic disease, decreased from diarrhea conditions and general the normal ESRs were shown in the sub-clinical or recovery stage of infections or disorders.

  • PDF

Angled Tube Method for Determining Erythrocyte Sedimentation Rate of Cattle (경사관법(傾斜管法)에 의한 우혈액(牛血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.175-185
    • /
    • 1986
  • The measurement of angled erythrocyte sedimentation rate (ESR), as a replacement for perpendicular ESR, for cattle blood was scrutinized since it has been well known that perpendicular ESR in cattle is too slow to be adopted as an effective clinical test. Samples of blood were taken from 186 Korean native cattle over 2 years old. The results obtained in the experiment were summarized as follows. 1. Average values of perpendicular ESR/24hrs in 15 apparently healthy cattle, as measured by Wintrobe, Westergren and capillary tubes, were $5.8{\pm}2.2$, $11.1{\pm}3.7$ and $10.4{\pm}4.5%$ respectively, which were found to be similar to the values of perpendicular ESR/hr of normal blood of human. 2. The ESR was determined in the tubes held at 90, 75, 60, 45, 30 and 15-degree angles, using 3 types of tubes. For the diagnostic purposes, the best results were obtained from the tubes held at 45-degree angle. 3. The angled ESR values increased as the diameters of the tube-bores decreased. 4. The tube length did not affect the angled ESR(%). 5. The angled ESR values increased with the increased environmental temperature during the ESR measurement. 6. The storage temperature at $5^{\circ}C$, $20^{\circ}C$ and $35^{\circ}C$, of the blood for 24 hours did not affect the angled ESR. 7. Samples of blood were treated with 4 kinds of anticoagulants (heparin, $K_2$-EDTA, double oxalate and sodium citrate) and the ESR was determined at 45-degree angle, using capillary hematocrit tubes. The ESR values were higher in the blood samples treated with sodium citrate than in those treated with other anticoagulants. 8. By using the autologous plasma, the PCV was adjusted to be 5, 10, 20, 30, 40 and 50ml/100ml and the ESR was determined in the capillary hematocrit and Wintrobe tubes held at 45 degrees. In both of the methods the ESRs increased as the values of PCV decreased. The regressions of ESR to PCV in both 45-degree-angled capillary and Wintrobe tubes were curvilinear. For the capillary hematocrit tubes the second degree polynomial $Y=61.9779-2.3533x+0.0228x^2$ (r=0.9999) fits the data. And in the case of Wintrobe tubes the second degree polynomial $Y=27.9767-1.1314x-0.0117x^2$ (r=0.9998) fits the data. 9. The 45-degree angled ESR was determined in the blood of 71 healthy Korean native cows using capillary hematocrit tubes. The average PCV was $35.4{\pm}3.6ml/100ml$. The observed ESR/hr averaged $7.2{\pm}2.7%$, while the corrected ESR/hr to a PCV of 36ml/100ml averaged $6.6{\pm}1.3%$. From these results it was concluded that to obtain the best results the ESR/hr of Korean native cattle should be determined at 45-degree angle at room temperature($20^{\circ}C$) using capillary hematocrit tubes.

  • PDF

Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat (경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Shin, Sung-shik;Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

Finite Element Analysis for Forming Processes of $\Omega$-type Bellows Tube (오메가형 벨로즈관의 성형을 위한 유한요소해석)

  • 이정훈;김낙수;전병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.165-170
    • /
    • 1997
  • The study presents an computer-aided analysis and its design for the forming process of $\Omega$-type bellows tube. Finite element analysis was carried out to perform the process simulation. Based on the analytic results of various conditions, the forming conditions used for angled U-type bellows tube were settled. The 3D modeling was constructed by I-DEAS and PAM-STAMP was used for process simulation. It is concluded that the spring back of formed bellows influences $\Omega$-shape and these results can be used for the process design.

  • PDF

Finite Element Analysis for Forming Processes of $\OMEGA$ -Type Bellows Tubes (오메가형 벨로즈관의 성형공정을 위한 유한요소해석)

  • Lee, Junghoon;Kim, Naksoo;Jeon, Byunghee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.85-90
    • /
    • 1997
  • The study presents a computer-aided analysis and its design for the forming process of .OMEGA. -type bellows tubes. Finite element analysis was carried out to perform the process simulation. Bsed on the analytic results of various conditions, the forming conditions used for angled U-type bellows tubes were determined. The 3-D modeling was constructed by I-DEAS and the process simulation was constructed by PAM- STAMP. It is concluded that the difference of height between die and bellows during the forming process causes a non-uniform shape of the bellows and also influences .OMEGA. -shape. These results can be utilized for the process design.

  • PDF

Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position (Supine 자세에서 Shoulder oblique촬영시 Tube angle 변화에 따른 Shoulder joint에 대한 고찰)

  • Seo, Jae-Hyun;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.109-114
    • /
    • 2008
  • There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were $1.10{\pm}0.54$ at $25^{\circ}$, $2.50{\pm}0.50$ at 30^{\circ}$, $2.85{\pm}0.36$ at $35^{\circ}$ and $2.33{\pm}0.47$ at $40^{\circ}$, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at $35^{\circ}$, $30^{\circ}$ and $40^{\circ}$ with the almost same score. However, the degree of distortion at $40^{\circ}$ was more severe than that at $30^{\circ}$. Ultimately, $30-35^{\circ}$ views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  • PDF

Endoscopic Removal of Traumatic Intracerebral Hematoma via Superolateral Keyhole (외상성 뇌실질내 혈종에 대한 상측방 키홀을 통한 내시경적 혈종 제거)

  • Park, Sung-Jin;Ha, Ho-Gyun;Jung, Ho;Lee, Sang-Keol;Park, Moon-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.249-254
    • /
    • 2000
  • Objective : As a minimally invasive strategy, endoscopic technique was introduced for removal of the traumatic intracerebral hematoma. Material and Method : A 54-year-old man with three-day history of seizure and progressive mental deterioration after traffic accident was presented. Computerized Tomography(CT) of the brain showed a huge intracerebral hematoma on the right frontal lobe and ventricle. The operation was performed via right frontal superolateral keyhole with 2cm eyebrow skin incision. Using 0-degree and 30-degree angled lens 4mm rigid endoscopes, nearly all of the hematoma was evacuated under the direct endoscopic visualization and a ventricular catheter was exactly placed into the frontal horn of the right lateral ventricle at the end of procedure. Results : The seizure was discontinued and neurological status had been improved during postoperative periods. Postoperative CT demonstrated that most of the hematoma was removed and the ventricular drainge tube was exactly placed in the right foramen of Monro. Conclusion : With endoscopic technique, the authors successfully evacuated traumatic intracerebral hematoma and exactly placed the ventricular drainage catheter under direct visualization. This technique may be considered as an another option for removal of traumatic intracerebral hematoma.

  • PDF